Electrocutaneous code pairs for artificial sensory communication systems

Pairs of electrocutaneous codes suitable for dual-channel sensory communication systems were compared using a dual-channel electrocutaneous tracking task. The tracking task required the test subject to dynamically respond to changes in the tactile sensation being modulated by two independent pseudorandom signals, one for each channel. The rule (or method) by which the signals changed the tactile sensations was called an electrocutaneous code. Four frequency variation codes and two intensity variation codes were paired in different combinations and then checked as to their effectiveness for sensory communications. The experimental protocol used a balanced incomplete block design which involved 24 subjects testing 3 of 8 code pairs each. Although the variance in the tracking performances between subjects was larger than the differences between the code pairs, learning rates for the various pairs were significantly different. The easiest one to learn was the Low Pulse Rate Modulation Code paired with itself. Other findings included the general superiority of monophasic stimulation code pairs over biphasic stimulation code pairs, the need for placement of the two electrodes on different dermatomes in order to achieve satisfactory dual-channel communications, and the greater sensitivity to electrocutaneous stimulation of the ventral side of the forearm versus its dorsal side.

[1]  John Lyman,et al.  Comparison of codes for sensory feedback using electrocutaneous tracking , 1977, Annals of Biomedical Engineering.

[2]  G. Rollman,et al.  Electrocutaneous stimulation: Psychometric functions and temporal integration , 1969 .

[4]  J D Meindl,et al.  Electrocutaneous stimulation in a reading aid for the blind. , 1971, IEEE transactions on bio-medical engineering.

[5]  H. Schmidt The importance of information feedback in prostheses for the upper limbs1 , 1977 .

[6]  John Lyman,et al.  Electrocutaneous Tracking: A Methodology for Evaluating Sensory Feedback Codes , 1979, IEEE Transactions on Biomedical Engineering.

[7]  William G. Cochran,et al.  Experimental Designs, 2nd Edition , 1950 .

[8]  A. Szeto,et al.  Electrocutaneous Pulse Rate and Pulse Width Psychometric Functions for Sensory Communications , 1979, Human factors.

[9]  R. H. Myers,et al.  Probability and Statistics for Engineers and Scientists , 1978 .

[10]  R. N. Scott,et al.  Sensory-feedback system compatible with myoelectric control , 2006, Medical and Biological Engineering and Computing.

[11]  George A. Bekey,et al.  Tactile Information Processing by Human Operators in Control Systems , 1978, IEEE Transactions on Systems, Man, and Cybernetics.

[12]  Carol A. Simpson,et al.  Speech perception via the tactile mode: Progress report , 1976, ICASSP.

[13]  Raymond H. Myers,et al.  Probability and Statistics for Engineers and Scientists. , 1973 .

[14]  Carter C. Collins,et al.  Tactile Television - Mechanical and Electrical Image Projection , 1970 .

[15]  Frank A. Saunders,et al.  Electrocutaneous Stimulation for Sensory Communication in Rehabilitation Engineering , 1982, IEEE Transactions on Biomedical Engineering.

[16]  A. E. Edmonds,et al.  Investigating the MESA (multipoint electrotactile speech aid): the transmission of segmental features of speech. , 1978, The Journal of the Acoustical Society of America.

[17]  B. Johansson,et al.  An Electrotactile'sound Detector for the Deaf , 1973 .

[18]  E. A. Pfeiffer,et al.  An experimental device to provide substitute tactile sensation from the anaesthetic hand , 2006, Medical and biological engineering.

[19]  M. Solomonow,et al.  Electrotactile two-point discrimination as a function of frequency, body site, laterality, and stimulation codes , 1977, Annals of Biomedical Engineering.

[20]  T. Beeker,et al.  Artificial touch in a hand-prosthesis , 2006, Medical and biological engineering.