Fetal heart rate monitoring: from Doppler to computerized analysis

The monitoring of fetal heart rate (FHR) status is an important method to check well-being of the baby during labor. Since the electronic FHR monitoring was introduced 40 years ago, it has been expected to be an innovative screening test to detect fetuses who are becoming hypoxic and who may benefit from cesarean delivery or operative vaginal delivery. However, several randomized controlled trials have failed to prove that electronic FHR monitoring had any benefit of reducing the perinatal mortality and morbidity. Also it is now clear that the FHR monitoring had high intra- and interobserver disagreements and increased the rate of cesarean delivery. Despite such limitations, the FHR monitoring is still one of the most important obstetric procedures in clinical practice, and the cardiotocogram is the most-used equipment. To supplement cardiotocogram, new methods of computerized FHR analysis and electrocardiogram have been developed, and several clinical researches have been currently performed. Computerized equipment makes us to analyze beat-to-beat variability and short term heart rate patterns. Furthermore, researches about multiparameters of FHR variability will be ongoing.

[1]  David A. Miller,et al.  A review of the 2008 NICHD Research Planning Workshop: recommendations for fetal heart rate terminology and interpretation. , 2011, Clinical obstetrics and gynecology.

[2]  S. Daly,et al.  Trends in intrapartum fetal death, 1979-2003. , 2008, American journal of obstetrics and gynecology.

[3]  S. Daly,et al.  Trends in intrapartum fetal death, 1979-2003 , 2008 .

[4]  J. Neilson,et al.  Fetal electrocardiogram (ECG) for fetal monitoring during labour. , 2013, The Cochrane database of systematic reviews.

[5]  Reza Tafreshi,et al.  Specific change in spectral power of fetal heart rate variability related to fetal acidemia during labor: comparison between preterm and term fetuses. , 2012, Early human development.

[6]  C. East,et al.  Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace. , 2010, The Cochrane database of systematic reviews.

[7]  J. Martin,et al.  Births: final data for 2002. , 2003, National vital statistics reports : from the Centers for Disease Control and Prevention, National Center for Health Statistics, National Vital Statistics System.

[8]  J. Dickinson,et al.  The paradox of electronic fetal monitoring: more data may not enable us to predict or prevent infant neurologic morbidity. , 1993, American journal of obstetrics and gynecology.

[9]  Jeffrey F Peipert,et al.  Electronic fetal monitoring as a public health screening program: the arithmetic of failure. , 2011, Obstetrics and gynecology.

[10]  Sergio Cerutti,et al.  Advances in monitoring cardiovascular signals. Contribution of nonlinear signal processing , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  A. Malliani,et al.  Heart rate variability. Standards of measurement, physiological interpretation, and clinical use , 1996 .

[12]  Richard Cookson,et al.  Royal College of Obstetricians and Gynaecologists. The Use of Electronic Fetal Monitoring full guidance published by the RCOG. RCOG Clinical Effectiveness Support Unit, London , 2001 .

[13]  R. Liston,et al.  Fetal health surveillance in labour. , 2002, Journal of obstetrics and gynaecology Canada : JOGC = Journal d'obstetrique et gynecologie du Canada : JOGC.

[14]  G. Macones,et al.  Intrapartum Fetal Heart Rate Monitoring: Nomenclature, Interpretation, and General Management Principles , 2009 .

[15]  A Costa-Pereira,et al.  Inconsistencies in classification by experts of cardiotocograms and subsequent clinical decision , 1999, British journal of obstetrics and gynaecology.

[16]  Kate C. Arnold,et al.  Intrapartum Fetal Heart Rate Monitoring: Nomenclature, Interpretation, and General Management Principles , 2017 .

[17]  Z. Alfirevic,et al.  Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. , 2006, The Cochrane database of systematic reviews.

[18]  K G Rosén,et al.  STAN--the Gothenburg model for fetal surveillance during labour by ST analysis of the fetal electrocardiogram. , 1989, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[19]  K. Leveno,et al.  Pathologic Fetal Acidemia , 1991, Obstetrics and gynecology.

[20]  S. Cerutti,et al.  Identification of vascular responses to exercise and orthostatic stress in bed rest-induced cardiovascular deconditioning , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  J. Bernardes,et al.  Evaluation of interobserver agreement of cardiotocograms , 1997, International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics.

[22]  M. Clarke,et al.  Professionals’ views of fetal monitoring during labour: a systematic review and thematic analysis , 2012, BMC Pregnancy and Childbirth.

[23]  E. Graham,et al.  Intrapartum electronic fetal heart rate monitoring and the identification of metabolic acidosis and hypoxic-ischemic encephalopathy. , 2007, American journal of obstetrics and gynecology.

[24]  A. Vintzileos,et al.  Comparison of intrapartum electronic fetal heart rate monitoring versus intermittent auscultation in detecting fetal acidemia at birth. , 1995, American journal of obstetrics and gynecology.

[25]  Z. J. Yang,et al.  The prediction of fetal acidosis at birth by computerised analysis of intrapartum cardiotocography , 1995, British journal of obstetrics and gynaecology.

[26]  I. van der Tweel,et al.  Inter‐ and intra‐observer agreement of intrapartum ST analysis of the fetal electrocardiogram in women monitored by STAN , 2009, BJOG : an international journal of obstetrics and gynaecology.

[27]  L. Oppenheimer,et al.  Power spectral analysis of fetal heart rate. , 1994, Bailliere's clinical obstetrics and gynaecology.

[28]  J. Espinoza,et al.  Clinical Management Guidelines for Obstetrician – Gynecologists , 2019 .

[29]  E. Fallen,et al.  Power spectral analysis of heart rate variability: a noninvasive signature of cardiac autonomic function. , 1993, Critical reviews in biomedical engineering.

[30]  G. Magenes,et al.  Multiparameter analysis of heart rate variability signal for the investigation of high risk fetuses , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[31]  G S Dawes,et al.  System 8000: Computerized antenatal FHR analysis , 1991, Journal of perinatal medicine.

[32]  J. V. van Laar,et al.  Spectral analysis of fetal heart rate variability for fetal surveillance: review of the literature , 2008, Acta obstetricia et gynecologica Scandinavica.

[33]  P. Nielsen,et al.  Intra‐ and inter‐observer variability in the assessment of intrapartum cardiotocograms , 1987 .

[34]  C. Spong,et al.  Antenatal Testing—A Reevaluation: Executive Summary of a Eunice Kennedy Shriver National Institute of Child Health and Human Development Workshop , 2009, Obstetrics and gynecology.

[35]  L. Oppenheimer,et al.  7 Power spectral analysis of fetal heart rate , 1994 .

[36]  Dwight J Rouse,et al.  A Randomized Trial of Intrapartum Fetal ECG ST-Segment Analysis. , 2015, The New England journal of medicine.

[37]  Ana Paula Rocha,et al.  Linear and nonlinear fetal heart rate analysis of normal and acidemic fetuses in the minutes preceding delivery , 2006, Medical and Biological Engineering and Computing.

[38]  Xiaotian Li,et al.  Approximate entropy of fetal heart rate variability as a predictor of fetal distress in women at term pregnancy , 2005, Acta obstetricia et gynecologica Scandinavica.

[39]  G. Breithardt,et al.  Heart rate variability: standards of measurement, physiological interpretation and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. , 1996 .

[40]  B Stigsby,et al.  Intra- and inter-observer variability in the assessment of intrapartum cardiotocograms. , 1988, Acta obstetricia et gynecologica Scandinavica.

[41]  George A. Macones,et al.  Intrapartum fetal heart rate monitoring: nomenclature, interpretation, and general management principles , 2009 .

[42]  Quantitative comparison of entropy analysis of fetal heart rate variability related to the different stages of labor. , 2014, Early human development.

[43]  D. Thurman,et al.  How common are the “common” neurologic disorders? , 2007, Neurology.