Autonomous demand response for frequency regulation on a large-scale model of an interconnected grid

This research examines the use of autonomous demand response to provide primary frequency control in an interconnected grid. The work builds on previous studies in several key areas: it uses a large realistic model; it establishes a set of metrics which can be used to assess the effectiveness of autonomous demand response; and it independently adjusts various parameters associated with using autonomous demand response to assess effectiveness and to examine possible threats or vulnerabilities associated with the technology. More than 6,000 simulations of the power system model were conducted during the course of the study. The studies demonstrated that very few conditions associated with autonomous demand response have the potential to degrade reliability, and that the marginal benefit attributable to autonomous demand response is quantifiable and can be used to determine the value of the technology, as compared to traditional means, for providing primary frequency control.

[1]  Yilu Liu,et al.  LAN-based control for load shedding , 2001 .

[2]  P. M. Anderson,et al.  An adaptive method for setting underfrequency load shedding relays , 1992 .

[3]  David W. Winiarski,et al.  End-use load control for power system dynamic stability enhancement , 1997 .

[4]  C. Concordia,et al.  Load shedding on an isolated system , 1995 .

[5]  Joseph H. Eto,et al.  Use of Frequency Response Metrics to Assess the Planning and Operating Requirements for Reliable Integration of Variable Renewable Generation , 2011 .

[6]  A.S. Davis Florida Power Corporation's load management system , 1990, IEEE Computer Applications in Power.

[7]  P. Erichsen,et al.  The results from a major load management project , 1989 .

[8]  A.G. Phadke,et al.  Study of global frequency dynamic behavior of large power systems , 2004, IEEE PES Power Systems Conference and Exposition, 2004..

[9]  D. Trudnowski,et al.  Power-System Frequency and Stability Control using Decentralized Intelligent Loads , 2006, 2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition.

[10]  B. Fox,et al.  Emergency control of frequency on the NIE system , 1988 .

[11]  Yuri V. Makarov,et al.  Assessing the Value of Regulation Resources Based on Their Time Response Characteristics , 2008 .

[12]  Daniel Trudnowski,et al.  Frequency and stability control using decentralized intelligent loads: Benefits and pitfalls , 2010, IEEE PES General Meeting.

[13]  Howard F. Illian Frequency Control Performance Measurement and Requirements , 2011 .

[14]  S. S. Venkata,et al.  An adaptive approach to load shedding and spinning reserve control during underfrequency conditions , 1996 .

[15]  B. J. Kirby,et al.  Spinning Reserve From Responsive Loads , 2003 .

[16]  R.G. Pratt Transforming the U.S. electricity system , 2004, IEEE PES Power Systems Conference and Exposition, 2004..