Design of Smart Ion-Selective Electrode Arrays Based on Source Separation through Nonlinear Independent Component Analysis

The development of chemical sensor arrays based on Blind Source Separation (BSS) provides a promising solution to overcome the interference problem associated with Ion-Selective Electrodes (ISE). The main motivation behind this new approach is to ease the time-demanding calibration stage. While the first works on this problem only considered the case in which the ions under analysis have equal valences, the present work aims at developing a BSS technique that works when the ions have different charges. In this situation, the resulting mixing model belongs to a particular class of nonlinear systems that have never been studied in the BSS literature. In order to tackle this sort of mixing process, we adopted a recurrent network as separating system. Moreover, concerning the BSS learning strategy, we develop a mutual information minimization approach based on the notion of the differential of the mutual information. The method works requires a batch operation, and, thus, can be used to perform off-line analysis. The validity of our approach is supported by experiments where the mixing model parameters were extracted from actual data.

[1]  Christian Jutten,et al.  Differential of the mutual information , 2004, IEEE Signal Processing Letters.

[2]  A. Martinez,et al.  Study of front-side connected chemical field effect transistor for water analysis , 2004, Microelectron. Reliab..

[3]  Yannick Deville,et al.  Stable Higher-Order Recurrent Neural Network Structures for Nonlinear Blind Source Separation , 2007, ICA.

[4]  Christian Jutten,et al.  Source separation in post-nonlinear mixtures , 1999, IEEE Trans. Signal Process..

[5]  Dermot Diamond,et al.  Potentiometric Nonlinear Multivariate Calibration with Genetic Algorithm and Simplex Optimization , 1997 .

[6]  Robert C. Hilborn,et al.  Chaos and Nonlinear Dynamics , 2000 .

[7]  Jiri Janata,et al.  Chemical Sensors: An Introduction for Scientists and Engineers , 2007 .

[8]  W. Simon,et al.  Ion-selective membrane electrodes for clinical use. , 1986, Clinical chemistry.

[9]  Robert C. Hilborn,et al.  Chaos And Nonlinear Dynamics: An Introduction for Scientists and Engineers , 1994 .

[10]  Ricardo Suyama,et al.  Unsupervised Signal Processing: Channel Equalization and Source Separation , 2010 .

[11]  Yannick Deville,et al.  Blind Separation of Linear-Quadratic Mixtures of Real Sources Using a Recurrent Structure , 2009, IWANN.

[12]  C. Jutten,et al.  Improving semiconductor-based chemical sensor arrays using advanced algorithms for blind source separation , 2004, ISA/IEEE Sensors for Industry Conference, 2004. Proceedings the.

[13]  Juha Karhunen,et al.  Advances in blind source separation (BSS) and independent component analysis (ICA) for nonlinear mixtures , 2004, Int. J. Neural Syst..

[14]  D. Pham FAST ALGORITHM FOR ESTIMATING MUTUAL INFORMATION, ENTROPIES AND SCORE FUNCTIONS , 2003 .

[15]  E. Bakker,et al.  General description of the simultaneous response of potentiometric ionophore-based sensors to ions of different charge. , 1999, Analytical chemistry.

[16]  俊一 甘利,et al.  A. Hyvärinen, J. Karhunen and E. Oja, Independent Component Analysis, Jhon Wiley & Sons, 2001年,504ページ. (根本幾・川勝真喜訳:独立成分分析——信号解析の新しい世界,東京電機大学出版局,2005年,532ページ.) , 2010 .

[17]  Christian Jutten,et al.  ISFET Source Separation: Foundations and Techniques , 2006 .

[18]  Pierre Comon,et al.  Independent component analysis, A new concept? , 1994, Signal Process..

[19]  Erkki Oja,et al.  Independent Component Analysis , 2001 .

[20]  Yoshio Umezawa,et al.  Potentiometric Selectivity Coefficients of Ion-Selective Electrodes. Part I. Inorganic Cations (Technical Report) , 2000 .

[21]  C Jutten,et al.  A Dataset for the Design of Smart Ion-Selective Electrode Arrays for Quantitative Analysis , 2010, IEEE Sensors Journal.

[22]  Robert B. Ash,et al.  Information Theory , 2020, The SAGE International Encyclopedia of Mass Media and Society.

[23]  Kiyoshi Toko,et al.  Evaluation of water quality and pollution using multichannel sensors , 2000 .

[24]  Pierre Comon,et al.  Handbook of Blind Source Separation: Independent Component Analysis and Applications , 2010 .

[25]  P. Bühlmann,et al.  Selectivity of potentiometric ion sensors. , 2000, Analytical chemistry.

[26]  Christian Jutten,et al.  Blind separation of sources, part I: An adaptive algorithm based on neuromimetic architecture , 1991, Signal Process..

[27]  Yannick Deville,et al.  Blind Maximum Likelihood Separation of a Linear-Quadratic Mixture , 2004, ICA.

[28]  Martin L Yarmush,et al.  Development of an array of ion-selective microelectrodes aimed for the monitoring of extracellular ionic activities. , 2006, Analytical chemistry.