Is visual outcome compromised when next day review is omitted after phacoemulsification surgery? A randomised control trial

Aims: To examine the safety implications of omitting first day clinical review following phacoemulsification cataract surgery. Methods: 362 patients were randomly assigned to “same day discharge” (SDD) or “next day review” (NDR). All patients were reviewed approximately 2 weeks after surgery. Results: Of the 174 patients randomised to NDR, 14 (8.0%) were treated for raised intraocular pressure (25–48 mm Hg) on the first postoperative day. Four received increased topical steroids for uveitis (two) and corneal oedema (two). One patient was treated for a significant wound leak. 12 (6.9%) required additional reviews before 2 week follow up for treatment of the following complications: drop toxicity (six), raised intraocular pressure (five), and corneal abrasion (one). Of the 188 randomised to SDD, six (3.2%) returned to the department before the planned review for reassurance of patients’ concerns regarding eye symptoms (three), drop toxicity (one) and follow up of previously raised intraocular pressure (one). There were two cases of iris prolapse in the SDD group. In one case, the complication was anticipated and early review had been arranged. Postoperative acuities of 6/12 or better were achieved in 83% of both SDD and NDR patients (p = 0.96 by χ2 test). Postoperative quality of life scores at 4 months indicating “no or hardly any concern about vision” (VCM1 questionnaire index <1.0) were achieved in 67% SDD and 72.5% NDR (p = 0.26). Conclusion: The intention to discharge patients on the day of surgery, with planned postoperative review at 2 weeks, was associated with a low frequency of serious ocular complications. Differences in the proportions achieving a good visual outcome between the two groups, based on 2 week visual acuity and 4 month quality of life, were not significant.

[1]  A. Rotchford,et al.  Role of intraocular pressure measurement on the day of phacoemulsification cataract surgery , 2002, Journal of cataract and refractive surgery.

[2]  O. Findl,et al.  Intraindividual comparison of the effects of a fixed dorzolamide–timolol combination and latanoprost on intraocular pressure after small incision cataract surgery , 2001, Journal of cataract and refractive surgery.

[3]  T. Peters,et al.  Reliability of the VCM1 Questionnaire when administered by post and by telephone , 2001, Ophthalmic epidemiology.

[4]  G. Heinze,et al.  Randomised fellow eye comparison of the effectiveness of dorzolamide and apraclonidine on intraocular pressure following phacoemulsification cataract surgery , 2000, Eye.

[5]  S. Dinakaran,et al.  Is the first post-operative day review necessary following uncomplicated phacoemulsification surgery? , 2000, Eye.

[6]  J. Lai,et al.  Latanoprost versus timolol gel to prevent ocular hypertension after phacoemulsification and intraocular lens implantation. , 2000, Journal of cataract and refractive surgery.

[7]  R. Burton,et al.  Phacoemulsification cataract surgery: is routine review necessary on the first post-operative day? , 2000, Eye.

[8]  A. Reidy,et al.  National cataract surgery survey 1997–8: a report of the results of the clinical outcomes , 1999, The British journal of ophthalmology.

[9]  A. Reidy,et al.  Profile of patients presenting for cataract surgery in the UK: national data collection , 1999, The British journal of ophthalmology.

[10]  D. Flanagan,et al.  Complications of phacoemulsification on the first postoperative day: can follow-up be safely changed? , 1999, Journal of cataract and refractive surgery.

[11]  J M Sparrow,et al.  Development of a questionnaire for measurement of vision-related quality of life. , 1998, Ophthalmic epidemiology.

[12]  K. Jordan,et al.  First day post-operative review following uncomplicated phacoemulsification , 1998, Eye.

[13]  P. Heyworth,et al.  Conventional routine clinical review may not be necessary after uncomplicated phacoemulsification , 1996, The British journal of ophthalmology.

[14]  M. Castilla,et al.  Ocular hypertension after cataract surgery: a comparison of three surgical techniques and two viscoelastics. , 1997, Ophthalmic surgery and lasers.

[15]  A. Barak,et al.  Early postoperative intraocular pressure pattern in glaucomatous and nonglaucomatous patients , 1996, Journal of cataract and refractive surgery.

[16]  J. Crowston,et al.  First day follow up for routine phacoemulsification? , 1996, The British journal of ophthalmology.

[17]  J. Funk,et al.  Intraocular pressure rise after phacoemulsification with posterior chamber lens implantation: effect of prophylactic medication, wound closure, and surgeon's experience. , 1995, The British journal of ophthalmology.

[18]  A. Foss,et al.  Is the first day postoperative review necessary after cataract extraction? , 1995, The British journal of ophthalmology.