A closed-form solution to fault parameter estimation and faulty phase identification of stator winding inter-turn fault in induction machines

Stator winding inter-turn fault is a common fault in induction machines. A substantial number of works have been developed for detection of this fault; however, there are only a few works on fault parameter estimation and faulty phase identification. In particular, there have been no works dealing with estimation of fault loop resistance. This paper presents a method for estimating the fraction of shorted turns and the fault loop resistance and identifying the faulty phase under steady-state condition. It provides a closed-form solution and hence is applicable to online fault detection and identification. Simulation results demonstrate the effectiveness of the proposed method.

[1]  A.H. Bonnett,et al.  Increased Efficiency Versus Increased Reliability , 2008, IEEE Industry Applications Magazine.

[2]  Humberto Henao,et al.  A frequency-domain detection of stator winding faults in induction machines using an external flux sensor , 2002 .

[3]  D. K. Perovic,et al.  Online stator fault diagnosis in induction motors , 2001 .

[4]  J. L. Kohler,et al.  Condition monitoring of stator windings in induction motors. II. Experimental investigation of voltage mismatch detectors , 2002 .

[5]  Carsten Skovmose Kallesoe Model-Based Stator Fault Detection in Induction Motors , 2008, 2008 IEEE Industry Applications Society Annual Meeting.

[6]  Gojko Joksimovic,et al.  The detection of inter-turn short circuits in the stator windings of operating motors , 2000, IEEE Trans. Ind. Electron..

[7]  T. G. Habetler,et al.  Insulation failure prediction in AC machines using line-neutral voltages , 1998 .

[8]  William James Premerlani,et al.  A new approach to on-line turn fault detection in AC motors , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[9]  Thomas G. Habetler,et al.  Transient model for induction machines with stator winding turn faults , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[10]  R. Maier,et al.  Protection of squirrel cage induction motor utilizing instantaneous power and phase information , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[11]  M. Arkan,et al.  Induction motor fault detection by space vector angular fluctuation , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[12]  T.G. Habetler,et al.  Insulation failure detection in the stator windings of ASD-driven induction machines using standard deviation of line currents , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[13]  R. M. Tallam,et al.  A robust, on-line turn-fault detection technique for induction machines based on monitoring the sequence component impedance matrix , 2003 .

[14]  Slim Tnani,et al.  Diagnosis by parameter estimation of stator and rotor faults occurring in induction machines , 2006, IEEE Transactions on Industrial Electronics.

[15]  H. Rasmussen,et al.  Estimation of stator winding faults in induction motors using an adaptive observer scheme , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[16]  S. Williamson,et al.  Analysis of Cage Induction Motors with Stator Winding Faults , 1985, IEEE Power Engineering Review.

[17]  J. Sottile,et al.  Condition monitoring of stator windings in induction motors. I. Experimental investigation of the effective negative-sequence impedance detector , 2002 .

[18]  F.C. Trutt,et al.  Condition monitoring of induction motor stator windings using electrically excited vibrations , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[19]  Djilali Toumi,et al.  Observer-based fault diagnosis and field oriented fault tolerant control of induction motor with stator inter-turn fault , 2012 .

[20]  A.J. Marques Cardoso,et al.  Stator winding fault diagnosis in three-phase synchronous and asynchronous motors, by the extended Park's vector approach , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[21]  M.I. Valla,et al.  Model Based Stator Fault Detection in Induction Motors , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[22]  Guillermo R. Bossio,et al.  Online Model-Based Stator-Fault Detection and Identification in Induction Motors , 2009, IEEE Transactions on Industrial Electronics.

[23]  M. Negrea Electromagnetic flux monitoring for detecting faults in electrical machines , 2006 .

[24]  J. Penman,et al.  Detection and location of interturn short circuits in the stator windings of operating motors , 1994 .