Transient Model of Air-Conditioner Compressor Single Phase Induction Motor

This paper describes an air-conditioner (A/C) compressor single phase induction motor (SPIM) model for use in an electro-magnetic transients (EMTs) simulation. The system of differential equations representing the SPIM model is developed and formulated. The angular position of the rotor shaft is retained in the electrical and mechanical equations of the model so that position dependence of the driven-load torque can be explicitly recognized. The equivalent circuit of the proposed model is represented as an interface to the external electric network in the EMTs simulator. Motor dynamic response to voltage dip at different points on the voltage waveform has been studied. The rationale of motor stalling is explored. Multiple aggregate units of the proposed model have been implemented on a distribution feeder to test and verify the motor dynamics in an EMTs simulation.

[1]  D. C. Dawson,et al.  Transmission voltage recovery delayed by stalled air conditioner compressors , 1992 .

[2]  J. W. Shaffer,et al.  Air conditioner response to transmission faults , 1997 .

[3]  Hermann W. Dommel,et al.  Digital Computer Solution of Electromagnetic Transients in Single-and Multiphase Networks , 1969 .

[4]  Wayne J. Morrill,et al.  The Revolving Field Theory of the Capacitor Motor , 1929, Transactions of the American Institute of Electrical Engineers.

[5]  Paul C. Krause,et al.  Simulation of Unsymmetrical 2-Phase Induction Machines , 1965 .

[6]  E.R. Collins,et al.  An experimental investigation of third harmonic current distortion in single-phase induction motors , 2008, 2008 13th International Conference on Harmonics and Quality of Power.

[7]  D. Kosterev,et al.  Phasor modeling approach for single phase A/C motors , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[8]  Yuan Liu Modeling of Air-Conditioner Compressor Single Phase Induction Motor for Transient Analysis , 2012 .

[9]  Aleksandar M. Stankovic,et al.  Modeling and analysis of single-phase induction machines with dynamic phasors , 1999 .

[10]  S. Ihara,et al.  Modeling air conditioner load for power system studies , 1998 .

[11]  P. Pourbeik,et al.  A hybrid model for representing air-conditioner compressor motor behavior in power system studies , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[12]  V. Stewart,et al.  Modeling of stalled motor loads for power system short-term voltage stability analysis , 2005, IEEE Power Engineering Society General Meeting, 2005.

[13]  Scott D. Sudhoff,et al.  Analysis of Electric Machinery and Drive Systems , 1995 .

[14]  V. Vittal,et al.  Dynamic VAr Planning in a Large Power System Using Trajectory Sensitivities , 2010, IEEE Transactions on Power Systems.