Modular Versus Nonmodular Femoral Necks for Primary Total Hip Arthroplasty.

In total hip arthroplasty (THA), proximal femoral neck stem modularity (PFNSM) has theoretical advantages over nonmodular stems, including the ability to more closely reconstruct anatomy and improve stability. However, risks of metallosis and breakage at the junction must be considered. In this study, we compared the head centers of a modular neck system with that of its nonmodular counterpart. Of 463 primary THAs with a modular stem, 261 (56%) had a head center equivalent to that of its nonmodular counterpart, and an additional 132 (29%) had a head center within 4 mm in length and 2 mm of offset. Thus, only 70 stems (15%) had a head center that was more than 4 mm in length and more than 2 mm in offset different from the nonmodular stem. Only 12 stems had a verted neck. These findings suggest that, in a majority of primary THAs, use of a modular stem results in head center positions also achievable with a nonmodular stem. Given the risks of modularity, PFNSM should be used with caution. We recommend PFNSM in cases that cannot be reconstructed with the nonmodular option.

[1]  C. Froemke,et al.  Modular versus Nonmodular Neck Femoral Implants in Primary Total Hip Arthroplasty: Which is Better? , 2014, Clinical orthopaedics and related research.

[2]  U. Dorn,et al.  Corrosion behavior of tantalum-coated cobalt-chromium modular necks compared to titanium modular necks in a simulator test. , 2014, The Journal of arthroplasty.

[3]  D. Sabbah,et al.  New type of hip arthroplasty failure related to modular femoral components: breakage at the neck-stem junction. , 2013, Orthopaedics & traumatology, surgery & research : OTSR.

[4]  J. De Schepper,et al.  Taper corrosion in modular hip prostheses: analysis of serum metal ions in 19 patients. , 2013, The Journal of arthroplasty.

[5]  R. Wixson,et al.  Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. , 2013, The Journal of bone and joint surgery. American volume.

[6]  M. Archibeck,et al.  Lessons Learned From Managing a Prospective, Private Practice Joint Replacement Registry: A 25-year Experience , 2013, Clinical orthopaedics and related research.

[7]  N. Sotereanos,et al.  Modular femoral neck fracture after primary total hip arthroplasty. , 2013, The Journal of arthroplasty.

[8]  J. Currier,et al.  Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips. , 2012, The Journal of arthroplasty.

[9]  E. Swarts,et al.  Proximal Component Modularity in THA—At What Cost?: An Implant Retrieval Study , 2012, Clinical orthopaedics and related research.

[10]  P. Megas,et al.  Dissociation of modular total hip arthroplasty at the neck–stem interface without dislocation , 2011, Journal of Orthopaedics and Traumatology.

[11]  M. Archibeck,et al.  A Comparison of Two Implant Systems in Restoration of Hip Geometry in Arthroplasty , 2011, Clinical orthopaedics and related research.

[12]  H. Schwartz,et al.  Trabecular metal endoprosthetic limb salvage reconstruction of the lower limb. , 2009, The Journal of arthroplasty.

[13]  J. Gilbert,et al.  Fretting crevice corrosion of stainless steel stem-CoCr femoral head connections: comparisons of materials, initial moisture, and offset length. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[14]  A. Spitzer The S-ROM cementless femoral stem: history and literature review. , 2005, Orthopedics.

[15]  R. Pietrobon,et al.  Comparison of a hydroxyapatite-coated sleeve and a porous-coated sleeve with a modular revision hip stem. A prospective, randomized study. , 2004, The Journal of bone and joint surgery. American volume.

[16]  S. Sporer,et al.  Primary total hip arthroplasty using a modular proximally coated prosthesis in patients older than 70: two to eight year results. , 2004, The Journal of arthroplasty.

[17]  C. Siebert,et al.  A modular femoral implant for uncemented stem revision in THR , 2000, International Orthopaedics.

[18]  W. Hozack,et al.  Head-neck modularity for total hip arthroplasty. Is it necessary? , 1996, The Journal of arthroplasty.

[19]  H. Cameron Modularity in primary total hip arthroplasty. , 1996, Journal of Arthroplasty.

[20]  Robert L. Barrack,et al.  Modularity of Prosthetic Implants , 1994, The Journal of the American Academy of Orthopaedic Surgeons.