Design and simulation of a 800 Mbit/s data link for magnetic resonance imaging wearables

This paper presents the optimization of electronic circuitry for operation in the harsh electro magnetic (EM) environment during a magnetic resonance imaging (MRI) scan. As demonstrator, a device small enough to be worn during the scan is optimized. Based on finite element method (FEM) simulations, the induced current densities due to magnetic field changes of 200 T s-1 were reduced from 1 × 1010 A m-2 by one order of magnitude, predicting error-free operation of the 1.8V logic employed. The simulations were validated using a bit error rate test, which showed no bit errors during a MRI scan sequence. Therefore, neither the logic, nor the utilized 800 Mbit s-1 low voltage differential swing (LVDS) data link of the optimized wearable device were significantly influenced by the EM interference. Next, the influence of ferro-magnetic components on the static magnetic field and consequently the image quality was simulated showing a MRI image loss with approximately 2 cm radius around a commercial integrated circuit of 1×1 cm2. This was successively validated by a conventional MRI scan.

[1]  Robert Turner,et al.  Transparent thin shield for radio frequency transmit coils , 2014, Magnetic Resonance Materials in Physics, Biology and Medicine.

[2]  B. G. Colpitts,et al.  Simulation and Verification of Magnetic Field Gradient Waveforms in the Presence of a Metallic Vessel in Magnetic Resonance Imaging , 2012, IEEE Transactions on Magnetics.

[3]  P. T. Gilbert 4.2 – Copper and Copper Alloys , 1976 .

[4]  Petros Martirosian,et al.  Metal artifacts caused by gradient switching , 2005, Magnetic resonance in medicine.

[5]  W. Marsden I and J , 2012 .

[6]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[7]  Jan G. Korvink,et al.  Implementation of an in-field CMOS frequency division multiplexer for 9.4 T magnetic resonance applications , 2015, Int. J. Circuit Theory Appl..

[8]  M. Gary Sayed,et al.  MRI BASIC PRINCIPLES AND APPLICATIONS , 1997 .

[9]  J. O'Reilly Series-parallel generation of m-sequences , 1975 .

[10]  Jack T Tanabe,et al.  Iron Dominated Electromagnets: Design, Fabrication, Assembly And Measurements , 2005 .

[11]  Reiner Salzer Biomedical imaging : principles and applications , 2012 .

[12]  Jörg Müller,et al.  Development of an Active Intravascular MR Device With an Optical Transmission System , 2008, IEEE Transactions on Medical Imaging.

[13]  Mark E Ladd,et al.  Reducing RF‐related heating of cardiac pacemaker leads in MRI: Implementation and experimental verification of practical design changes , 2012, Magnetic resonance in medicine.

[14]  Wilson Fong Handbook of MRI Pulse Sequences , 2005 .

[15]  Günhan Dündar,et al.  An Optically Powered CMOS Tracking System for 3 T Magnetic Resonance Environment , 2015, IEEE Transactions on Biomedical Circuits and Systems.

[16]  Wolfhard Semmler,et al.  MAGNETIC RESONANCE TOMOGRAPHY , 2008 .

[17]  David Jin,et al.  Advances in Future Computer and Control Systems , 2012 .