Performance of two domestic solar water heaters with drain water heat recovery units: Simulation and experimental investigation

Abstract This paper presents an investigation on the performances of drain water heat recovery (DWHR) system and two solar domestic water heaters (SDWH). The DWHR units and water heater systems were recently installed side-by-side at the Archetype Sustainable Twin Houses at Kortright Center, Vaughan, Ontario. The first SDWH system in House A consists of a flat plate solar thermal collector in conjunction with a gas boiler and a DWHR unit. The second SDHW system in House B consists of an evacuated tube solar collector, an electric tank, and a DWHR unit. The extrapolated results based on the experimental study showed that the DWHR unit is capable of an annual heat recovery of 789 kWh and an overall effectiveness of about 50%. The flat plate and evacuated tubes collectors based SDWH systems produce an annual thermal energy output of 2038 kWh and 1383 kWh, respectively.

[1]  Yong Kim,et al.  Thermal performances comparisons of the glass evacuated tube solar collectors with shapes of absorber tube , 2007 .

[2]  Wilfried Zörner,et al.  Performance of Vacuum Tube and Flat Plate Collectors Con- cerning Domestic Hot Water Preparation and Room Heating , 2005 .

[3]  Merih Aydinalp,et al.  Modeling of the space and domestic hot-water heating energy-consumption in the residential sector using neural networks , 2004 .

[4]  Michaël Kummert,et al.  On the combined effect of wastewater heat recovery and solar domestic hot water heating , 2006 .

[5]  Michael Conlon,et al.  Comparative Field Performance Study of Flat Plate and Heat Pipe Evacuated Tube Collectors (ETCs) for Domestic Water Heating Systems in a Temperate Climate , 2011 .

[6]  Wenfeng Gao,et al.  Comparative studies on thermal performance of water-in-glass evacuated tube solar water heaters with different collector tilt-angles , 2011 .

[7]  Ian Paul Knight,et al.  Residential Cogeneration Systems: European and Canadian Residential Non-HVAC Electric and DHW Load Profiles For Use in Simulating the Performance of Residential Cogeneration Systems , 2007 .

[8]  Enrico Zambolin,et al.  Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions , 2010 .

[9]  L. Wong,et al.  Shower water heat recovery in high-rise residential buildings of Hong Kong , 2010 .

[10]  H. P. Garg,et al.  Thermal performance of a solar pressure cooker based on evacuated tube solar collector , 2001 .

[11]  J. D. Seader,et al.  Fully developed viscous—flow heat transfer in curved circular tubes with uniform wall temperature , 1974 .