A numerical method to determine the steady state distribution of passive contaminant in generic ventilation systems

Abstract Ventilation system with air recirculation is designed to conserve energy, yet at the same time may result in transporting hazardous substance among different rooms in the same building, which is a concern in indoor air quality control. There is a lack of effective methods to predict indoor contaminant distribution primarily because of uncertainty of the contaminant concentration in supply air which in turn due to the mixing ratio of fresh and recirculation air. In this paper, a versatile numerical method to determine the pollutant distribution of ventilation system with recirculation at steady state is proposed based on typical ventilation systems with accessibility of supply air (ASA) and accessibility of contaminant source (ACS). The relationship is established between contaminant concentrations of supply air and return air in a ventilated room or zone. The concentrations of supply air and contaminant distribution in each room can be determined using such parameters as ASA and ACS. The proposed method is validated by both experimental data and numerical simulation result. The computing speed of the proposed method is compared with the iteration method. The comparisons between the proposed method and the lumped parameter model are also conducted. The advantages of the proposed method in terms of accuracy, speed and versatility make it advantageous to be applied in air quality control of complex ventilation systems with recirculation.

[1]  Henrik Brohus,et al.  Proceedings of Indoor Air 2008 , 2008 .

[2]  Bin Zhao,et al.  Prediction of transient contaminant dispersion and ventilation performance using the concept of accessibility , 2004 .

[3]  Zhao Bin Algorithm for quickly calculating the pollutant distribution in central ventilation systems , 2004 .

[4]  Y. Lisa Chen,et al.  Sensor system design for building indoor air protection , 2008 .

[5]  B. Launder,et al.  The numerical computation of turbulent flows , 1990 .

[6]  Xiaoliang Shao,et al.  A theoretical model to calculate the distribution of air age in general ventilation system , 2012 .

[7]  Jelena Srebric,et al.  Performance of three air distribution systems in VOC removal from an area source , 2004 .

[8]  Qingyan Chen,et al.  Floor-Supply Displacement Ventilation in a Small Office , 2003 .

[9]  Qingyan Chen,et al.  System Performance Evaluation and Design Guidelines for Displacement Ventilation , 1999 .

[10]  Per Heiselberg,et al.  Room Air and Contaminant Distribution in Mixing Ventilation , 1996 .

[11]  Zhao Bin Distribution of the contaminant concentration in rooms with fan-coil units and fresh air supplies , 2004 .

[12]  Xianting Li,et al.  A simplified system for indoor airflow simulation , 2003 .

[13]  A. Melikov,et al.  Personalized ventilation: evaluation of different air terminal devices , 2002 .

[14]  Xianting Li,et al.  Accessibility: A New Concept to Evaluate Ventilation Performance in a Finite Period of Time , 2004 .

[15]  K. Sexton,et al.  Indoor air pollution: a public health perspective. , 1983, Science.

[16]  Helmut E. Feustel COMIS—an international multizone air-flow and contaminant transport model , 1999 .

[17]  P. Nielsen,et al.  Contaminant Distribution around Persons in Rooms Ventilated by Displacement Ventilation , 1994 .

[18]  S. Kato,et al.  CFD analysis on characteristics of contaminated indoor air ventilation and its application in the evaluation of the effects of contaminant inhalation by a human occupant , 2002 .

[19]  L. Wallace,et al.  Indoor particles: a review. , 1996, Journal of the Air & Waste Management Association.

[20]  Qingyan Chen,et al.  A zero-equation turbulence model for indoor airflow simulation , 1998 .