Hot small-signal S-parameter measurements of power transistors operating under large-signal conditions in a load-pull environment for the study of nonlinear parametric interactions

This paper presents a setup that enables wide-band (in-band and out-of-band) measurements of hot small-signal S-parameters of nonlinear devices driven by a large-signal single tone (namely, the pump signal). A load-pull characterization is performed at the pump frequency (F/sub 0/), while hot small-signal S-parameters are measured with a perturbating signal at a frequency (f) by the use of a probe tone. Basically, the frequency of the probe tone is swept over a wide bandwidth (at the present time from 300 MHz up to F/sub 0//2). A higher frequency range, from near dc to KF/sub 0/, will be implemented in a similar manner. The measurement setup reported here is applied to on-wafer measurements of S-band HBTs. Hot small-signal S-parameter measurements versus large-signal load impedance and pump level will be shown. An application to the prediction of parametric oscillations will be demonstrated. A parametric oscillation predicted at 373 MHz is confirmed by spectrum measurements.

[1]  Denis Barataud,et al.  Measurement and control of current/voltage waveforms of microwave transistors using a harmonic load-pull system for the optimum design of high efficiency power amplifiers , 1999, IEEE Trans. Instrum. Meas..

[2]  C. Tsironis,et al.  Highly accurate harmonic tuners for load pull testing , 2001, APMC 2001. 2001 Asia-Pacific Microwave Conference (Cat. No.01TH8577).

[3]  M.B. Steer,et al.  A novel envelope-termination load-pull method for ACPR optimization of RF/microwave power amplifiers , 1998, 1998 IEEE MTT-S International Microwave Symposium Digest (Cat. No.98CH36192).

[4]  Andrea Pierenrico Ferrero,et al.  Recent technological advances for modular active harmonic load-pull measurement systems , 1999 .

[5]  R. W. Jackson,et al.  Criteria for the onset of oscillation in microwave circuits , 1992 .

[6]  Fadhel M. Ghannouchi,et al.  Simultaneous load-pull of intermodulation and output power under two-tone excitation for accurate SSPA's design , 1994, IEEE Transactions on Microwave Theory and Techniques.

[7]  S. Mons,et al.  A unified approach for the linear and nonlinear stability analysis of microwave circuits using commercially available tools , 1999, 1999 IEEE MTT-S International Microwave Symposium Digest (Cat. No.99CH36282).

[8]  G. Kompa,et al.  A new on-wafer large-signal waveform measurement system with 40 GHz harmonic bandwidth , 1992, 1992 IEEE Microwave Symposium Digest MTT-S.

[9]  D. Barataud,et al.  A new characterization technique of "Four hot S parameters" for the study of nonlinear parametric behaviors of microwave devices , 2003, IEEE MTT-S International Microwave Symposium Digest, 2003.

[10]  Philippe Bouysse,et al.  A novel, accurate load-pull setup allowing the characterization of highly mismatched power transistors , 1994 .

[11]  G. Collinson,et al.  A novel technique for measuring small signal S-parameters of an RF/microwave transistor, power amplifying stage for use in power amplifier stability analysis , 1993, 1993 IEEE MTT-S International Microwave Symposium Digest.

[12]  W. Struble,et al.  Instabilities diagnosis and the role of K in microwave circuits , 1993, 1993 IEEE MTT-S International Microwave Symposium Digest.

[13]  J. Martens,et al.  Probe-tone S-parameter measurements , 2002 .

[14]  P.J. Tasker,et al.  A study of the effect of envelope impedance on intermodulation asymmetry using a two-tone time domain measurement system , 2002, 2002 IEEE MTT-S International Microwave Symposium Digest (Cat. No.02CH37278).

[15]  J. Rollett Stability and Power-Gain Invariants of Linear Twoports , 1962 .

[16]  Andrea Pierenrico Ferrero,et al.  An improved calibration technique for on-wafer large-signal transistor characterization , 1993 .

[17]  R. G. Freitag,et al.  A unified analysis of MMIC power amplifier stability , 1992, 1992 IEEE Microwave Symposium Digest MTT-S.

[18]  E. Bergeault,et al.  Automated characterization of HF power transistors by source-pull and multiharmonic load-pull measurements based on six-port techniques , 1998 .