Utility of three-dimensional echocardiography during balloon mitral valvuloplasty.

OBJECTIVES We investigated the role of three-dimensional echocardiography in assessing mitral valve anatomy in greater detail in patients immediately before and after balloon mitral valvuloplasty (BMV). BACKGROUND Three-dimensional echocardiography is a recently developed, evolving imaging technique that allows visualization of intracardiac structures from any perspective. METHODS We studied 19 patients undergoing BMV using transesophageal echocardiography (TEE) (Chicago, Illinois) to image the mitral valve. The TEE was interfaced to a TomTec three-dimensional workstation that allows electrocardiographic and respiratory cycle gated image acquisition. The acquired images are digitized, and after postprocessing a three-dimensional image is reconstructed. The mitral valve was viewed "en-face" as if looking up from the left ventricle. RESULTS The mean mitral valve area (by pressure half-time from the Doppler of the two-dimensional echocardiogram) increased after BMV from 0.86+/-0.06 cm2 to 2.07+/-0.10 cm2, p < 0.0001. This was similar to the mitral valve areas obtained by planimetry from the three-dimensional images. The three-dimensional reconstructions showed a complete commissural split in 10 patients and partial splitting in 9 patients. In three of the eight patients who had an increase in the amount of mitral regurgitation secondary to BMV, the three-dimensional reconstructions were able to detect tears within the valve leaflet. One leaflet tear actually extended up to the mitral valve annulus and was associated with the only case of severe mitral regurgitation. CONCLUSIONS The three-dimensional echocardiographic reconstruction enabled visualization of the mitral valve so that commissural splitting and leaflet tears not seen on the two-dimensional echocardiogram became visible.

[1]  S. Goldstein,et al.  Mitral stenosis. Evaluation and guidance of valvuloplasty by transesophageal echocardiography. , 1993, Cardiology clinics.

[2]  G. Francis,et al.  Echocardiographic criteria of normal left atrial size in adults. , 1976, Catheterization and cardiovascular diagnosis.

[3]  I. Palacios,et al.  Echocardiography can predict which patients will develop severe mitral regurgitation after percutaneous mitral valvulotomy. , 1996, Journal of the American College of Cardiology.

[4]  J. Wynne,et al.  Percutaneous balloon valvuloplasty compared with open surgical commissurotomy for mitral stenosis. , 1994, The New England journal of medicine.

[5]  N G Pandian,et al.  Delineation of site, relative size and dynamic geometry of atrial septal defects by real-time three-dimensional echocardiography. , 1995, Journal of the American College of Cardiology.

[6]  K Inoue,et al.  Clinical application of transvenous mitral commissurotomy by a new balloon catheter. , 1984, The Journal of thoracic and cardiovascular surgery.

[7]  M. Monaghan,et al.  The value of transthoracic echocardiography during percutaneous balloon mitral valvuloplasty. , 1995, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[8]  I. Palacios,et al.  Prediction of successful outcome in 130 patients undergoing percutaneous balloon mitral valvotomy. , 1990, Circulation.

[9]  Z. Turi,et al.  Percutaneous balloon mitral valvuloplasty. , 1997, Progress in cardiovascular diseases.

[10]  W. Daniel,et al.  Echocardiographic and hemodynamic characteristics of atrial septal defects created by percutaneous valvuloplasty. , 1990, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[11]  I. Kronzon,et al.  Transesophageal echocardiography during percutaneous mitral valvuloplasty. , 1989, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[12]  I. Kronzon,et al.  Transesophageal echocardiography to detect atrial clots in candidates for percutaneous transseptal mitral balloon valvuloplasty. , 1990, Journal of the American College of Cardiology.

[13]  T O Cheng,et al.  Four-dimensional echocardiography: methods and clinical application. , 1996, American heart journal.

[14]  A Salustri,et al.  Three-dimensional echocardiography of the thoracic aorta. , 1996, European heart journal.

[15]  A. Sivaraman,et al.  Balloon mitral valvotomy: an autopsy study. , 1995, International Journal of Cardiology.

[16]  L Hatle,et al.  Noninvasive Assessment of Atrioventricular Pressure Half‐time by Doppler Ultrasound , 1979, Circulation.

[17]  Simulation of Intraoperative Visualization of Cardiac Structures and Study of Dynamic Surgical Anatomy with Real-Time Three Dimensional Echocardiography , 1994 .

[18]  G. Marx,et al.  Dynamic Three‐Dimensional Echocardiography: , 1994 .

[19]  T. Bashore,et al.  Complications related to percutaneous transvenous mitral commissurotomy. , 1994, Catheterization and cardiovascular diagnosis.

[20]  I. Palacios,et al.  Inaccuracy of mitral pressure half-time immediately after percutaneous mitral valvotomy. Dependence on transmitral gradient and left atrial and ventricular compliance. , 1988, Circulation.

[21]  F J Ten Cate,et al.  Three-dimensional echocardiography of normal and pathologic mitral valve: a comparison with two-dimensional transesophageal echocardiography. , 1996, Journal of the American College of Cardiology.