Attomolar protein detection in complex sample matrices with semi-homogeneous fluidic force discrimination assays.

We describe a semi-homogenous (SH) implementation of a fluidic force discrimination (FFD) assay using only two reagent mixtures and three assay steps that can be performed in as little as 10min. Previously microbead labels and FFD have been combined to achieve multiplexed, femtomolar nucleic acid hybridization and immunoassays in a microarray format [Mulvaney, S.P., Cole, C.L., Kniller, M.D., Malito, M., Tamanaha, C.R., Rife, J.C., Stanton, M.W., Whitman, L.J., 2007. Biosen. Bioelectron. 23, 191-200.]. In SH FFD assays, the microbeads and any required intermediate receptors (e.g., secondary antibodies) are first mixed directly with a sample, allowing target analytes to be efficiently captured onto the beads. The target-loaded beads are then specifically captured onto a microarray surface, with nonspecifically bound beads removed by controlled, laminar fluidic forces. The remaining beads on each microarray capture spot are counted to determine the targets' identities and concentrations. SH target collection provides a 1000-fold improvement in the assay sensitivity, down to attomolar concentrations, as demonstrated by our detection of staphylococcal enterotoxin B (SEB) at 35 aM (1 fg/ml). We also show that SH assays are adaptable for extraction, preconcentration, and identification of analytes in complex sample matrices, including assays for SEB and ricin toxoid in serum and whole blood. Finally, we present a detailed model of the reaction kinetics that reveals how capturing the targets onto the beads in solution provides a significant kinetic advantage at low target concentrations where mass transport to a microarray surface is most limited.

[1]  C. Mirkin,et al.  Nanoparticle-based detection in cerebral spinal fluid of a soluble pathogenic biomarker for Alzheimer's disease. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[2]  T. Graczyk,et al.  Rapid Microsphere Assay for Identification of Cryptosporidium hominis and Cryptosporidium parvum in Stool and Environmental Samples , 2007, Journal of Clinical Microbiology.

[3]  H. Berg,et al.  Physics of chemoreception. , 1977, Biophysical journal.

[4]  J. Landers,et al.  Evaluation of silica resins for direct and efficient extraction of DNA from complex biological matrices in a miniaturized format. , 2000, Analytical biochemistry.

[5]  C P Price,et al.  The matrix effects on kinetic rate constants of antibody-antigen interactions reflect solvent viscosity. , 1998, Journal of immunological methods.

[6]  K. Ainslie,et al.  Formation of primary amines on silicon nitride surfaces: a direct, plasma-based pathway to functionalization. , 2007, Langmuir : the ACS journal of surfaces and colloids.

[7]  David R. Walt,et al.  Fluorescence-based nucleic acid detection and microarrays , 2002 .

[8]  R. Colton,et al.  The BARC biosensor applied to the detection of biological warfare agents. , 2000, Biosensors & bioelectronics.

[9]  Gil U. Lee,et al.  A biosensor based on magnetoresistance technology. , 1998, Biosensors & bioelectronics.

[10]  C. Mirkin,et al.  Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins , 2003, Science.

[11]  Jwa-Min Nam,et al.  Colorimetric bio-barcode amplification assay for cytokines. , 2005, Analytical chemistry.

[12]  Chad A Mirkin,et al.  The bio-barcode assay for the detection of protein and nucleic acid targets using DTT-induced ligand exchange , 2006, Nature Protocols.

[13]  Nicole Jaffrezic-Renault,et al.  Biosensors and Bio-Bar Code Assays Based on Biofunctionalized Magnetic Microbeads , 2007, Sensors (Basel, Switzerland).

[14]  Chad A Mirkin,et al.  Nanoparticle-Based Biobarcode Amplification Assay (BCA) for Sensitive and Early Detection of Human Immunodeficiency Type 1 Capsid (p24) Antigen , 2007, Journal of acquired immune deficiency syndromes.

[15]  J. Mahony,et al.  Development of a Respiratory Virus Panel Test for Detection of Twenty Human Respiratory Viruses by Use of Multiplex PCR and a Fluid Microbead-Based Assay , 2007, Journal of Clinical Microbiology.

[16]  F Bender,et al.  Comparative study of IgG binding to proteins G and A: nonequilibrium kinetic and binding constant determination with the acoustic waveguide device. , 2003, Analytical chemistry.

[17]  Stephanie Groves,et al.  Three minutes-long electrophoretically assisted zeptomolar microfluidic immunoassay with magnetic-beads detection. , 2007, Journal of the American Chemical Society.

[18]  G. S. Wilson,et al.  Characterization of Protein Adsorption and Immunosorption Kinetics in Photoablated Polymer Microchannels , 2000 .

[19]  B. Hoffmann,et al.  A universal heterologous internal control system for duplex real-time RT-PCR assays used in a detection system for pestiviruses. , 2006, Journal of virological methods.

[20]  B. M. de Boer,et al.  An integrated and sensitive detection platform for magneto-resistive biosensors. , 2007, Biosensors & bioelectronics.

[21]  Igor L. Medintz,et al.  TNT detection using multiplexed liquid array displacement immunoassays. , 2006, Analytical chemistry.

[22]  L. Whitman,et al.  Rapid, femtomolar bioassays in complex matrices combining microfluidics and magnetoelectronics. , 2007, Biosensors & bioelectronics.

[23]  N. Greenspan,et al.  Variable domain-identical antibodies exhibit IgG subclass-related differences in affinity and kinetic constants as determined by surface plasmon resonance. , 1994, Molecular immunology.

[24]  Paul E. Sheehan,et al.  Design and Performance of GMR Sensors for the Detection of Magnetic Microbeads in Biosensors , 2003 .

[25]  Edward L Cussler,et al.  Diffusion: Mass Transfer in Fluid Systems , 1984 .

[26]  L. Whitman,et al.  Magnetic labeling, detection, and system integration. , 2008, Biosensors & bioelectronics.

[27]  P. Sheehan,et al.  Detection limits for nanoscale biosensors. , 2005, Nano letters.

[28]  Paul E. Sheehan,et al.  A DNA array sensor utilizing magnetic microbeads and magnetoelectronic detection , 2001 .

[29]  Hugo Ferreira,et al.  Magnetic field-assisted DNA hybridisation and simultaneous detection using micron-sized spin-valve sensors and magnetic nanoparticles , 2005 .

[30]  I. Mackay Real-time PCR in the microbiology laboratory. , 2004, Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases.

[31]  Chad A Mirkin,et al.  Bio-bar-code-based DNA detection with PCR-like sensitivity. , 2004, Journal of the American Chemical Society.

[32]  Raj Mutharasan,et al.  Detection and confirmation of staphylococcal enterotoxin B in apple juice and milk using piezoelectric-excited millimeter-sized cantilever sensors at 2.5 fg/mL. , 2007, Analytical chemistry.

[33]  Wen Li,et al.  Establishment of multiplexed, microsphere-based flow cytometric assay for multiple human tumor markers , 2007, Acta Pharmacologica Sinica.

[34]  Daniel L Graham,et al.  Magnetoresistive-based biosensors and biochips. , 2004, Trends in biotechnology.

[35]  Chad A Mirkin,et al.  A fluorophore-based bio-barcode amplification assay for proteins. , 2006, Small.

[36]  Chad A Mirkin,et al.  A bio-barcode assay for on-chip attomolar-sensitivity protein detection. , 2006, Lab on a chip.

[37]  Shimon Weiss,et al.  The power and prospects of fluorescence microscopies and spectroscopies. , 2003, Annual review of biophysics and biomolecular structure.

[38]  T. Barbari,et al.  Specific capture of target proteins by oriented antibodies bound to tyrosinase-immobilized Protein A on a polyallylamine affinity membrane surface , 2006 .

[39]  A. Lorusso,et al.  A minor groove binder probe real-time PCR assay for discrimination between type 2-based vaccines and field strains of canine parvovirus , 2006, Journal of Virological Methods.