Morphometric analysis in three-dimensional intracoronary ultrasound: an in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaque.

Currently, automated systems for quantitative analysis by intracoronary ultrasound (ICUS) are restricted to the detection of the lumen. The aim of this study was to determine the accuracy and reproducibility of a new semiautomated contour detection method, providing off-line identification of the intimal leading edge and external contour of the vessel in three-dimensional ICUS. The system allows cross-sectional and volumetric quantification of lumen and of plaque. It applies a minimum-cost algorithm and the concept that edge points derived from previously detected longitudinal contours guide and facilitate the contour detection in the cross-sectional images. A tubular phantom with segments of various luminal dimensions was examined in vitro during five catheter pull-backs (1 mm/sec), and subsequently 20 diseased human coronary arteries were studied in vivo with 2.9F 30 MHz mechanical ultrasound catheters (200 images per 20 mm segment). The ICUS measurements of phantom lumen area and volume revealed a high correlation with the true phantom areas and volumes (r = 0.99); relative mean differences were -0.65% to 3.86% for the areas and 0.25% to 1.72% for the volumes of the various segments. Intraob-server and interobserver comparisons showed high correlations (r = 0.95 to 0.98 for area and r = 0.99 for volume) and small mean relative differences (-0.87% to 1.08%), with SD of lumen, plaque, and total vessel measurements not exceeding 7.28%, 10.81%, and 4.44% (area) and 2.66%, 2.81%, and 0.67% (volume), respectively. Thus the proposed analysis system provided accurate measurements of phantom dimensions and can be used to perform highly reproducible area and volume measurements in three-dimensional ICUS in vivo.

[1]  R A Wilson,et al.  Detection and characterization of vascular lesions by intravascular ultrasound: an in vitro study correlated with histology. , 1992, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[2]  P. Dhawale,et al.  Optimal data acquisition for volumetric intracoronary ultrasound. , 1994, Catheterization and cardiovascular diagnosis.

[3]  R A Robb,et al.  Three-Dimensional Volumetric Ultrasound Imaging of Arterial Pathology from Two-Dimensional Intravascular Ultrasound: An in Vitro Study , 1994, Angiology.

[4]  J. Isner,et al.  Three‐Dimensional Reconstruction of Human Coronary and Peripheral Arteries From Images Recorded During Two‐Dimensional Intravascular Ultrasound Examination , 1991, Circulation.

[5]  C J Slager,et al.  Volumetric intracoronary ultrasound: a new maximum confidence approach for the quantitative assessment of progression-regression of atherosclerosis? , 1995, Atherosclerosis.

[6]  F. Prati,et al.  Dynamic three-dimensional reconstruction of ICUS images based on an ECG-gated pull-back device , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  C J Slager,et al.  Three-dimensional reconstruction of intracoronary ultrasound images. Rationale, approaches, problems, and directions. , 1994, Circulation.

[8]  M. Leon,et al.  Use of intracoronary ultrasound to identify the "true" coronary lumen in chronic coronary dissection treated with intracoronary stenting. , 1992, The American journal of cardiology.

[9]  C. Buller,et al.  Mechanisms of balloon angioplasty and directional coronary atherectomy as assessed by intracoronary ultrasound. , 1992, Journal of the American College of Cardiology.

[10]  F Prati,et al.  Optimized expansion of the Wallstent compared with the Palmaz-Schatz stent: on-line observations with two- and three-dimensional intracoronary ultrasound after angiographic guidance. , 1996, American heart journal.

[11]  van den Maarten Berg,et al.  COMPUTERS IN CARDIOLOGY 1995 , 1995 .

[12]  E. Topol,et al.  Current Review of Interventional Cardiology , 1997 .

[13]  P J de Feyter,et al.  Can intracoronary ultrasound correctly assess the luminal dimensions of coronary artery lesions? A comparison with quantitative angiography. , 1995, European heart journal.

[14]  Raimund Erbel,et al.  Three dimensional reconstruction of intracoronary ultrasound images: roadmapping with simultaneously digitised coronary angiograms , 1993, Proceedings of Computers in Cardiology Conference.

[15]  F J Pinto,et al.  Intracoronary Ultrasound in Cardiac Transplant Recipients: In Vivo Evidence of “Angiographically Silent” Intimal Thickening , 1991, Circulation.

[16]  S. Goldberg,et al.  Intracoronary ultrasound observations during stent implantation. , 1994, Circulation.

[17]  N. Bom,et al.  Semi-automatic contour detection for volumetric quantification of intracoronary ultrasound , 1994, Computers in Cardiology 1994.

[18]  Michael C. Fishbein,et al.  In vitro validation of three-dimensional intravascular ultrasound for the evaluation of arterial injury after balloon angioplasty. , 1992, Journal of the American College of Cardiology.

[19]  M. Leon,et al.  Three‐dimensional intravascular ultrasonography: Reconstruction of endovascular stents in vitro and in vivo , 1993, Journal of clinical ultrasound : JCU.

[20]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[21]  Wenguang Li,et al.  Dynamic three-dimensional reconstruction of ICUS images based on an EGG-gated pull-back device , 1995 .

[22]  Hellmuth Hertz Principles of ultrasound in medical diagnosis , 1977 .

[23]  R. Erbel,et al.  Intravascular ultrasound imaging of angiographically normal coronary arteries: a prospective study in vivo. , 1994, British heart journal.

[24]  Jan A. Oomen,et al.  734-6 ANGUS: A New Approach to Three-dimensional Reconstruction of Geometry and Orientation of Coronary Lumen and Plaque by Combined Use of Coronary Angiography and IVUS , 1995 .

[25]  G. Heninger,et al.  PHENOXYBENZAMINE IN ANOREXIA NERVOSA , 1976, The Lancet.

[26]  M. Leon,et al.  Intravascular Ultrasound Evaluation of the Effect of Rotational Atherectomy in Obstructive Atherosclerotic Coronary Artery Disease , 1992, Circulation.

[27]  J. Griffith,et al.  Intravascular ultrasound cross-sectional arterial imaging before and after balloon angioplasty in vitro. , 1989, Circulation.

[28]  D. M. Abouelnasr,et al.  Resolution limitations in intravascular ultrasound imaging. , 1993, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[29]  Steven E. Nissen,et al.  Intravascular Ultrasound Assessment of Lumen Size and Wall Morphology in Normal Subjects and Patients With Coronary Artery Disease , 1991, Circulation.

[30]  Frits Mastik,et al.  Image Segmentation and 3D Reconstruction of Intravascular Ultrasound Images , 1993 .

[31]  R. Virmani,et al.  Coronary artery lumen volume measurement using three-dimensional intravascular ultrasound: validation of a new technique. , 1994, Catheterization and cardiovascular diagnosis.

[32]  F Prati,et al.  Mechanism of high-speed rotational atherectomy and adjunctive balloon angioplasty revisited by quantitative coronary angiography: edge detection versus videodensitometry. , 1995, American heart journal.

[33]  P. Fitzgerald,et al.  Intracoronary ultrasound imaging: intraobserver and interobserver variability of morphometric measurements. , 1994, American heart journal.

[34]  C von Birgelen,et al.  Quantification of the minimal luminal cross-sectional area after coronary stenting by two- and three-dimensional intravascular ultrasound versus edge detection and videodensitometry. , 1996, The American journal of cardiology.

[35]  P. Yock,et al.  Intravascular ultrasound. Looking below the surface of vascular disease. , 1990, Circulation.

[36]  J. Isner,et al.  Focal compensatory enlargement of human arteries in response to progressive atherosclerosis. In vivo documentation using intravascular ultrasound. , 1994, Circulation.

[37]  J. Hodgson,et al.  Intracoronary ultrasound imaging: correlation of plaque morphology with angiography, clinical syndrome and procedural results in patients undergoing coronary angioplasty. , 1993, Journal of the American College of Cardiology.

[38]  W. French,et al.  Usefulness of intravascular ultrasound imaging for detecting experimentally induced aortic dissection in dogs and for determining the effectiveness of endoluminal stenting. , 1992, The American journal of cardiology.

[39]  C von Birgelen,et al.  Quantitative assessment with intracoronary ultrasound of the mechanisms of restenosis after percutaneous transluminal coronary angioplasty and directional coronary atherectomy. , 1995, The American journal of cardiology.

[40]  Xiangmin Zhang,et al.  Automated segmentation of coronary wall and plaque from intravascular ultrasound image sequences , 1994, Computers in Cardiology 1994.

[41]  Francesco Prati,et al.  Three dimensional reconstruction of cross sectional intracoronary ultrasound: clinical or research tool? , 1995, British heart journal.