Increasing signal to noise ratio and minimizing artefacts in biomedical instrumentation systems

Capturing a near-perfect, artefact free signal is an ideal of biomedicine. However, this depends on the removal of different types of artefact, all of which can be considered unwanted noise on the desired signal. Failure to remove artefacts could lead to a clinical misinterpretation of the results. All medical equipment such as electrocardiogram systems which use electrodes attached to patients suffer from artefacts, with effects ranging from minor blurring to significant distortion of the output signal(s). For this reason, it is important to identify how artefacts can influence the output signal. In this paper, we propose a new technique to detect and minimise movement artefacts using strain gauges embedded into the electrodes.

[1]  Khalil Najafi,et al.  On-chip characterization of scale-factor of a MEMS gyroscope via a micro calibration platform , 2017, 2017 IEEE International Symposium on Inertial Sensors and Systems (INERTIAL).

[2]  Jie Yan,et al.  Fast-settling CMOS operational amplifiers with negative conductance voltage gain enhancement , 2001, ISCAS 2001. The 2001 IEEE International Symposium on Circuits and Systems (Cat. No.01CH37196).

[3]  Guang-Zhong Yang,et al.  Ratiometric Artifact Reduction in Low Power Reflective Photoplethysmography , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[4]  Wouter A. Serdijn,et al.  Ultra Low-Power Biomedical Signal Processing , 2009 .

[5]  Wouter A. Serdijn,et al.  Ultra Low-Power Biomedical Signal Processing: An Analog Wavelet Filter Approach for Pacemakers , 2009 .

[6]  J. Silva-Martinez,et al.  Design considerations for biomedical signal interfaces , 1999, Proceedings of the Third International Workshop on Design of Mixed-Mode Integrated Circuits and Applications (Cat. No.99EX303).

[7]  Randall L. Geiger,et al.  A negative conductance voltage gain enhancement technique for low voltage high speed CMOS op amp design , 2000, Proceedings of the 43rd IEEE Midwest Symposium on Circuits and Systems (Cat.No.CH37144).

[8]  Feng Wan,et al.  A 90nm CMOS bio-potential signal readout front-end with improved powerline interference rejection , 2009, 2009 IEEE International Symposium on Circuits and Systems.

[9]  Shunli Ma,et al.  A low power programmable band-pass filter with novel pseudo-resistor for portable biopotential acquisition system , 2012, 2012 IEEE Asia Pacific Conference on Circuits and Systems.

[10]  R. Jacob Baker,et al.  CMOS Circuit Design, Layout, and Simulation , 1997 .

[11]  Zheng Chang,et al.  Design and Application of a Digital Filter of Mains Frequency , 2009, 2009 WRI World Congress on Computer Science and Information Engineering.