Motion correction with PROPELLER MRI: Application to head motion and free‐breathing cardiac imaging

A method for motion correction, involving both data collection and reconstruction, is presented. The PROPELLER MRI method collects data in concentric rectangular strips rotated about the k‐space origin. The central region of k‐space is sampled for every strip, which (a) allows one to correct spatial inconsistencies in position, rotation, and phase between strips, (b) allows one to reject data based on a correlation measure indicating through‐plane motion, and (c) further decreases motion artifacts through an averaging effect for low spatial frequencies. Results are shown in which PROPELLER MRI is used to correct for bulk motion in head images and respiratory motion in nongated cardiac images. Magn Reson Med 42:963–969, 1999. © 1999 Wiley‐Liss, Inc.

[1]  C. Ahn,et al.  High-Speed Spiral-Scan Echo Planar NMR Imaging-I , 1986, IEEE Transactions on Medical Imaging.

[2]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[3]  D Chien,et al.  Fast selective black blood MR imaging. , 1991, Radiology.

[4]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.

[5]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[6]  Bob S. Hu,et al.  Fast Spiral Coronary Artery Imaging , 1992, Magnetic resonance in medicine.

[7]  R. Ordidge,et al.  Correction of motional artifacts in diffusion-weighted MR images using navigator echoes. , 1994, Magnetic resonance imaging.

[8]  Todd S. Sachs,et al.  The diminishing variance algorithm for real‐time reduction of motion artifacts in MRI , 1995, Magnetic resonance in medicine.

[9]  D G Nishimura,et al.  A Velocity k‐Space Analysis of Flow Effects in Echo‐Planar and Spiral Imaging , 1995, Magnetic resonance in medicine.

[10]  William F. Eddyy,et al.  Improved image registration by using fourier interpolation , 1996, Magnetic resonance in medicine.

[11]  D. Alsop Phase insensitive preparation of single‐shot RARE: Application to diffusion imaging in humans , 1997, Magnetic resonance in medicine.

[12]  F. Schick SPLICE: Sub‐second diffusion‐sensitive MR imaging using a modified fast spin‐echo acquisition mode , 1997, Magnetic resonance in medicine.

[13]  Luis C. Maas,et al.  Decoupled automated rotational and translational registration for functional MRI time series data: The dart registration algorithm , 1997, Magnetic resonance in medicine.

[14]  J. Pauly,et al.  Isotropic diffusion‐weighted and spiral‐navigated interleaved EPI for routine imaging of acute stroke , 1997, Magnetic resonance in medicine.

[15]  J. Pipe,et al.  Sampling density compensation in MRI: Rationale and an iterative numerical solution , 1999, Magnetic resonance in medicine.