Doppler Radar Noncontact Vital Sign Monitoring

This chapter presents the noncontact and noninvasive approach for monitoring human vital signs using Doppler radar sensor. The theory of noncontact vital sign detection is based on Doppler phase modulation. The system-level hardware architectures of the Doppler radar sensor have been illustrated. Research groups all over the world have been working for decades to improve the performance of Doppler radar noncontact vital sign detection. While some groups improved the performance from the hardware side, e.g., using quadrature receiver to avoid the null point problem, some groups took effort from the software side. For example, new demodulation techniques such as complex demodulation have been invented. System-on-chip (SoC) integration is also a major interest of the researchers working on Doppler radar sensors. With all the circuits integrated into one chip, the radar can be much smaller so as to be more portable or more easily integrated with other communication devices, e.g., cell phones. Several examples of radar sensor SoC have been introduced in this chapter. The Doppler radar sensor sees a bright future in medical applications. It is expected to bring enhanced healthcare in the near future. This chapter introduces the potential applications such as infants monitoring, sleep apnea detection, pulse wave velocity measurement, respiration measurement in motion-adaptive cancer radiotherapy, and so forth.

[1]  Ghaïs El Zein,et al.  Noncontact heartbeat detection at 2.4, 5.8, and 60 GHz: A comparative study , 2009 .

[2]  Changzhi Li,et al.  A 5GHz Double-Sideband Radar Sensor Chip in 0.18 $\mu$m CMOS for Non-Contact Vital Sign Detection , 2008, IEEE Microwave and Wireless Components Letters.

[3]  Changzhi Li,et al.  Experimental demonstration of noncontact pulse wave velocity monitoring using multiple Doppler radar sensors , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[4]  Jenshan Lin,et al.  Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring , 2004, IEEE Transactions on Microwave Theory and Techniques.

[5]  Jenshan Lin,et al.  0.25 /spl mu/m CMOS and BiCMOS single-chip direct-conversion Doppler radars for remote sensing of vital signs , 2002, 2002 IEEE International Solid-State Circuits Conference. Digest of Technical Papers (Cat. No.02CH37315).

[6]  Jenshan Lin,et al.  Frequency-tuning technique for remote detection of heartbeat and respiration using low-power double-sideband transmission in the ka-band , 2006, IEEE Transactions on Microwave Theory and Techniques.

[7]  J. Lin,et al.  Experiment and Spectral Analysis of a Low-Power $Ka$-Band Heartbeat Detector Measuring From Four Sides of a Human Body , 2006, IEEE Transactions on Microwave Theory and Techniques.

[8]  Teh-Ho Tao,et al.  UWB radar for patient monitoring , 2008, IEEE Aerospace and Electronic Systems Magazine.

[9]  Steve B. Jiang,et al.  Technical aspects of image-guided respiration-gated radiation therapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[10]  Steve B. Jiang,et al.  Accurate Respiration Measurement Using DC-Coupled Continuous-Wave Radar Sensor for Motion-Adaptive Cancer Radiotherapy , 2012, IEEE Transactions on Biomedical Engineering.

[11]  Changzhi Li,et al.  Verification of a non-contact vital sign monitoring system using an infant simulator , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  Changzhan Gu,et al.  A multi-radar wireless system for respiratory gating and accurate tumor tracking in lung cancer radiotherapy , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  J. D. Bourland,et al.  Measurement of pulse-wave velocity using a beat-sampling technique , 2006, Annals of Biomedical Engineering.

[14]  D. Hoyert,et al.  Annual summary of vital statistics: 2000. , 2001, Pediatrics.

[15]  William L. Smith,et al.  Near-Continuous Profiling of Temperature, Moisture, and Atmospheric Stability Using the Atmospheric Emitted Radiance Interferometer (AERI) , 2003 .

[16]  Victor Lubecke,et al.  Respiratory monitoring using a doppler radar with passive harmonic tags to reduce interference from environmental clutter , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[17]  James C. Lin,et al.  Microwave sensing of physiological movement and volume change: a review. , 1992, Bioelectromagnetics.

[18]  D. Samardzija,et al.  Doppler radar sensing of multiple subjects in single and multiple antenna systems , 2005, TELSIKS 2005 - 2005 uth International Conference on Telecommunication in ModernSatellite, Cable and Broadcasting Services.

[19]  Steve B. Jiang,et al.  Doppler radar respiration measurement for gated lung cancer radiotherapy , 2011, 2011 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems.

[20]  Olga Boric-Lubecke,et al.  Detection of Multiple Heartbeats Using Doppler Radar , 2006, 2006 IEEE International Conference on Acoustics Speech and Signal Processing Proceedings.

[21]  Jenshan Lin,et al.  Optimal Carrier Frequency of Non-contact Vital Sign Detectors , 2007, 2007 IEEE Radio and Wireless Symposium.

[22]  E. M. Staderini,et al.  UWB radars in medicine , 2002 .

[23]  Steve B. Jiang Radiotherapy of mobile tumors. , 2006, Seminars in radiation oncology.

[24]  Luigi Ferrucci,et al.  Pulse wave velocity is an independent predictor of the longitudinal increase in systolic blood pressure and of incident hypertension in the Baltimore Longitudinal Study of Aging. , 2008, Journal of the American College of Cardiology.

[25]  Yong Huang,et al.  Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier , 2000, IEEE Transactions on Biomedical Engineering.

[26]  J. Blacher,et al.  Impact of aortic stiffness on survival in end-stage renal disease. , 1999, Circulation.

[27]  J. Blacher,et al.  Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients. , 1999, Hypertension.

[28]  Albert Hofman,et al.  Arterial Stiffness and Risk of Coronary Heart Disease and Stroke: The Rotterdam Study , 2006, Circulation.

[29]  O. Boric-Lubecke,et al.  Range correlation effect on ISM band I/Q CMOS radar for non-contact vital signs sensing , 2003, IEEE MTT-S International Microwave Symposium Digest, 2003.

[30]  Changzhi Li,et al.  Complex signal demodulation and random body movement cancellation techniques for non-contact vital sign detection , 2008, IMS 2008.

[31]  A. Kales,et al.  Sleep and its disorders. , 1999, Annual review of medicine.

[32]  O. Boric-Lubecke,et al.  Radar cross section of human cardiopulmonary activity for recumbent subject , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[33]  Changzhi Li,et al.  Random Body Movement Cancellation in Doppler Radar Vital Sign Detection , 2008, IEEE Transactions on Microwave Theory and Techniques.

[34]  H. Bazett,et al.  MEASUREMENTS OF PULSE WAVE VELOCITY , 1922 .

[35]  O. Boric-Lubecke,et al.  Microwave non-invasive sensing of respiratory tidal volume , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[36]  Changzhi Li,et al.  Microwave noncontact measurement of pulse wave velocity for healthcare applications , 2010, 2010 IEEE 11th Annual Wireless and Microwave Technology Conference (WAMICON).

[37]  Byung-Kwon Park,et al.  Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems , 2007, IEEE Transactions on Microwave Theory and Techniques.

[38]  Jeffrey M. Hausdorff,et al.  Self-Organized Biological Dynamics and Nonlinear Control: Fractal mechanisms in neuronal control: human heartbeat and gait dynamics in health and disease , 2000 .

[39]  J.C. Lin Noninvasive microwave measurement of respiration , 1975, Proceedings of the IEEE.

[40]  A. Stelzer,et al.  A microwave position sensor with sub-millimeter accuracy , 1999, 1999 IEEE MTT-S International Microwave Symposium Digest (Cat. No.99CH36282).

[41]  Noah Hafner,et al.  Performance assessment techniques for doppler radar physiological sensors , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[42]  Changzhi Li,et al.  Software configurable 5.8 GHz radar sensor receiver chip in 0.13 µm CMOS for non-contact vital sign detection , 2009, 2009 IEEE Radio Frequency Integrated Circuits Symposium.

[43]  Rich Fletcher,et al.  Low-cost differential front-end for Doppler radar vital sign monitoring , 2009, 2009 IEEE MTT-S International Microwave Symposium Digest.

[44]  H. H. Meinel,et al.  Commercial applications of millimeterwaves: history, present status, and future trends , 1995 .

[45]  O. Boric-Lubecke,et al.  Non-contact respiratory rate measurement validation for hospitalized patients , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.