Validation of object-induced MR distortion correction for frameless stereotactic neurosurgery

Spatial fidelity is a paramount issue in image guided neurosurgery. Until recently, three-dimensional computed tomography (3D CT) has been the primary modality because it provides fast volume capture with pixel level (1 mm) accuracy. While three-dimensional magnetic resonance (3D MR) images provide superior anatomic information, published image capture protocols are time consuming and result in scanner- and object-induced magnetic field inhomogeneities which raise inaccuracy above pixel size. Using available scanner calibration software, a volumetric algorithm to correct for object-based geometric distortion, and a Fast Low Angle SHot (FLASH) 3D MR-scan protocol, the authors were able to reduce mean CT to MR skin-adhesed fiducial marker registration error from 1.36 to 1.09 mm. After dropping the worst one or two of six fiducial markers, mean registration error dropped to 0.62 mm (subpixel accuracy). Three dimensional object-induced error maps present highest 3D MR spatial infidelity at the tissue interfaces (skin/air, scalp/skull) where frameless stereotactic fiducial markers are commonly applied. The algorithm produced similar results in two patient 3D MR-scans.

[1]  R. Kikinis,et al.  Computer-assisted interactive three-dimensional planning for neurosurgical procedures. , 1996, Neurosurgery.

[2]  M A Moerland,et al.  Analysis and correction of geometric distortions in 1.5 T magnetic resonance images for use in radiotherapy treatment planning. , 1995, Physics in medicine and biology.

[3]  Ching-Ming Lai Reconstructing NMR images under magnetic fields with large inhomogeneities , 1982 .

[4]  R. Meuli,et al.  Assessment of MR image deformation for stereotactic neurosurgery using a tagging sequence. , 1994, AJNR. American journal of neuroradiology.

[5]  J. Fitzpatrick,et al.  Correcting scaling errors in tomographic images using a nine degree of freedom registration algorithm. , 1998, Journal of computer assisted tomography.

[6]  K. Sekihara,et al.  NMR Imaging for Magnets with Large Nonuniformities , 1985, IEEE Transactions on Medical Imaging.

[7]  B. Rosen,et al.  Magnetic susceptibility effects of trabecular bone on magnetic resonance imaging of bone marrow. , 1990, Investigative radiology.

[8]  A method to reduce systematic spatial shift associated with magnetic resonance imaging. , 1996, Stereotactic and functional neurosurgery.

[9]  L Walton,et al.  A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with the Leksell stereotactic system. , 1996, Neurosurgery.

[10]  David C. Wilson,et al.  Comparison of Traditional Brain Segmentation Tools with 3D Self-Organizing Maps , 1997, IPMI.

[11]  B Aubert,et al.  A technique of measuring the precision of an MR-guided stereotaxic installation using anatomic specimens. , 1994, AJNR. American journal of neuroradiology.

[12]  A. Jouvet,et al.  CT-guided needle biopsy of intracranial tumours: results in 118 consecutive patients. , 1995, Acta neurochirurgica. Supplement.

[13]  J. Torner,et al.  Computed tomography versus magnetic resonance imaging in stereotactic localization. , 1994, Stereotactic and functional neurosurgery.

[14]  B. Dawant,et al.  Effect of geometrical distortion correction in MR on image registration accuracy. , 1996, Journal of computer assisted tomography.

[15]  L. Lemieux,et al.  Accuracy in frame-based and frameless stereotaxy. , 1993, Stereotactic and functional neurosurgery.

[16]  V Sturm,et al.  Correction of spatial distortion in MR imaging: a prerequisite for accurate stereotaxy. , 1987, Journal of computer assisted tomography.

[17]  M van Herk,et al.  Magnetic resonance image-directed stereotactic neurosurgery: use of image fusion with computerized tomography to enhance spatial accuracy. , 1995, Journal of neurosurgery.

[18]  R.J. Maciunas,et al.  An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head , 1996, IEEE Transactions on Biomedical Engineering.

[19]  E. Cosman,et al.  Brown-Roberts-Wells stereotactic frame modifications to accomplish magnetic resonance imaging guidance in three planes. , 1987, Applied neurophysiology.

[20]  D. Kondziolka,et al.  Use of magnetic resonance imaging in stereotactic surgery. A survey of members of the American Society of Stereotactic and Functional Neurosurgery. , 1996, Stereotactic and functional neurosurgery.

[21]  J. Hutchison,et al.  NMR imaging: image recovery under magnetic fields with large non-uniformities. , 1978, Journal of physics E: Scientific instruments.

[22]  Robert L. Galloway,et al.  A three-dimensional locating pointer for stereotactic neurosurgery , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[23]  K J Burchiel,et al.  MRI distortion and stereotactic neurosurgery using the Cosman-Roberts-Wells and Leksell frames. , 1996, Stereotactic and functional neurosurgery.

[24]  B R Rosen,et al.  Selective Saturation NMR Imaging , 1984, Journal of computer assisted tomography.

[25]  J. Fitzpatrick,et al.  A universal method for geometric correction of magnetic resonance images for stereotactic neurosurgery. , 1996, Stereotactic and functional neurosurgery.

[26]  H E Rockette,et al.  The effect of image processing on chest radiograph interpretations in a PACS environment. , 1990, Investigative radiology.

[27]  R J Maciunas,et al.  Stereotactic neurosurgery. , 1990, Critical reviews in biomedical engineering.

[28]  J. Michael Fitzpatrick,et al.  A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities , 1992, IEEE Trans. Medical Imaging.

[29]  G. Glover,et al.  Characterization of spatial distortion in magnetic resonance imaging and its implications for stereotactic surgery. , 1994, Neurosurgery.

[30]  K. Sekihara,et al.  Image restoration from non-uniform magnetic field influence for direct Fourier NMR imaging. , 1984, Physics in medicine and biology.

[31]  David Dean,et al.  The wrapper: a surface optimization algorithm that preserves highly curved areas , 1994, Other Conferences.

[32]  P. Röschmann,et al.  Susceptibility artefacts in NMR imaging. , 1985, Magnetic resonance imaging.

[33]  T. S. Sumanaweera,et al.  Segmentation and distortion correction in medical imaging , 1992 .

[34]  J. Michael Fitzpatrick,et al.  Partial-volume effect on marker localization in medical density images , 1997, Medical Imaging.

[35]  Z H Cho,et al.  Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting. , 1988, Medical physics.

[36]  V M Haughton,et al.  Magnetic susceptibility artifacts in gradient-recalled echo MR imaging. , 1988, AJNR. American journal of neuroradiology.

[37]  G. Glover,et al.  Mr geometric distortion correction for improved frame‐based stereotaxic target localization accuracy , 1995, Magnetic resonance in medicine.

[38]  E. Feig,et al.  Magnetic resonance imaging with non-uniform fields , 1986 .

[39]  G. Glover,et al.  Rapid in vivo proton shimming , 1991, Magnetic resonance in medicine.