A real-time measure of cavitation induced tissue disruption by ultrasound imaging backscatter reduction

A feedback method for obtaining real-time information on the mechanical disruption of tissue through ultrasound cavitation is presented. This method is based on a substantial reduction in ultrasound imaging backscatter from the target volume as the tissue structure is broken down. Ex-vivo samples of porcine liver were exposed to successive high-intensity ultrasound pulses at a low duty cycle to induce mechanical disruption of tissue parenchyma through cavitation (referred to as histotripsy). At the conclusion of treatment, B-scan imaging backscatter was observed to have decreased by 22.4 plusmn 2.3 dB in the target location. Treated samples of tissue were found to contain disrupted tissue corresponding to the imaged hypoechoic volume with no remaining discernable structure and a sharp boundary. The observed, substantial backscatter reduction may be an effective feedback mechanism for assessing treatment efficacy in ultrasound surgery using pulsed ultrasound to create cavitation

[1]  J. E. Parsons,et al.  Pulsed cavitational ultrasound therapy for controlled tissue homogenization. , 2006, Ultrasound in medicine & biology.

[2]  Tryphon T. Georgiou,et al.  Noninvasive estimation of tissue temperature via high-resolution spectral analysis techniques , 2005, IEEE Transactions on Biomedical Engineering.

[3]  C.A. Cain,et al.  Treatment planning for hyperthermia with ultrasound phased arrays , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  J Brian Fowlkes,et al.  Pulsed cavitational ultrasound: a noninvasive technology for controlled tissue ablation (histotripsy) in the rabbit kidney. , 2006, The Journal of urology.

[5]  Morton W. Miller,et al.  A review of in vitro bioeffects of inertial ultrasonic cavitation from a mechanistic perspective. , 1996, Ultrasound in medicine & biology.

[6]  Z. Xu,et al.  Controlled ultrasound tissue erosion , 2003, IEEE Symposium on Ultrasonics, 2003.

[7]  Gregg E Trahey,et al.  Acoustic radiation force impulse imaging of thermally- and chemically-induced lesions in soft tissues: preliminary ex vivo results. , 2004, Ultrasound in medicine & biology.

[8]  K Hynynen,et al.  The feasibility of using focused ultrasound for transmyocardial revascularization. , 1998, Ultrasound in medicine & biology.

[9]  K Hynynen,et al.  A focused ultrasound method for simultaneous diagnostic and therapeutic applications--a simulation study. , 2001, Physics in medicine and biology.

[10]  C. Cain,et al.  Imaging feedback of tissue liquefaction (histotripsy) in ultrasound surgery , 2005, IEEE Ultrasonics Symposium, 2005..

[11]  J. E. Parsons,et al.  Cost-effective assembly of a basic fiber-optic hydrophone for measurement of high-amplitude therapeutic ultrasound fields. , 2006, The Journal of the Acoustical Society of America.

[12]  J Bercoff,et al.  Monitoring Thermally-Induced Lesions with Supersonic Shear Imaging , 2004, Ultrasonic imaging.

[13]  K. Kuroda,et al.  A precise and fast temperature mapping using water proton chemical shift , 1995, Magnetic resonance in medicine.

[14]  F A Jolesz,et al.  Invited. Calibration of water proton chemical shift with temperature for noninvasive temperature imaging during focused ultrasound surgery , 1998, Journal of magnetic resonance imaging : JMRI.

[15]  J. Chapelon,et al.  Differential Attenuation Imaging for the Characterization of High Intensity Focused Ultrasound Lesions , 1998, Ultrasonic imaging.

[16]  H. Katus,et al.  Therapeutic Use of Ultrasound Targeted Microbubble Destruction: A Review of Non-Cardiac Applications , 2006, Ultraschall in der Medizin.

[17]  S. Alam,et al.  Radiation-force technique to monitor lesions during ultrasonic therapy. , 2003, Ultrasound in medicine & biology.

[18]  J. Tavakkoli,et al.  Ultrasound-induced tissue ablation: studies on isolated, perfused porcine liver. , 1998, Ultrasound in medicine & biology.

[19]  Morton W. Miller,et al.  Biological consequences of hyperthermia. , 1989, Ultrasound in medicine & biology.

[20]  Jeffrey C Bamber,et al.  Fundamental limitations of noninvasive temperature imaging by means of ultrasound echo strain estimation. , 2002, Ultrasound in medicine & biology.

[21]  R.M. Arthur,et al.  Temperature dependence of ultrasonic backscattered energy in motion compensated images , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  K. Hynynen The threshold for thermally significant cavitation in dog's thigh muscle in vivo. , 1991, Ultrasound in medicine & biology.

[23]  N. Sanghvi,et al.  Automated HIFU treatment planning and execution based on 3D modeling of the prostate, urethra, and rectal wall , 2004, IEEE Ultrasonics Symposium, 2004.

[24]  P. VanBaren,et al.  Two-dimensional temperature estimation using diagnostic ultrasound , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  M. Fink,et al.  Temperature estimation using ultrasonic spatial compound imaging , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  J. Tavakkoli,et al.  A piezocomposite shock wave generator with electronic focusing capability: application for producing cavitation-induced lesions in rabbit liver. , 1997, Ultrasound in medicine & biology.

[27]  Hirokazu Miyoshi,et al.  Encapsulated ultrasound microbubbles: therapeutic application in drug/gene delivery. , 2006, Journal of controlled release : official journal of the Controlled Release Society.

[28]  R. Ton,et al.  Threshold Ultrasonic Dosages for Structural Changes in the Mammalian Brain * , 2004 .

[29]  R. Apfel,et al.  Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound. , 1991, Ultrasound in medicine & biology.

[30]  J. Lingeman,et al.  Shockwave lithotripsy: dose-related effects on renal structure, hemodynamics, and tubular function. , 2005, Journal of endourology.

[31]  M. O’Donnell,et al.  Evaluation of ultrasound tissue damage based on changes in image echogenicity in canine kidney , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[32]  M. Jordan,et al.  Biological effects of shock waves: cavitation by shock waves in piglet liver. , 1990, Ultrasound in medicine & biology.

[33]  C. Cain,et al.  Effects of contrast agent infusion rates on thresholds for tissue damage produced by single exposures of high-intensity ultrasound , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[34]  Kullervo Hynynen,et al.  Focal beam distortion and treatment planning in abdominal focused ultrasound surgery. , 2005 .

[35]  Z. Sun,et al.  A multi-gate time-of-flight technique for estimation of temperature distribution in heated tissue: theory and computer simulation. , 1999, Ultrasonics.

[36]  F. L. Thurstone,et al.  Acoustic Speckle: Theory and Experimental Analysis , 1979 .

[37]  K Hynynen,et al.  MRI monitoring of the thermal ablation of tissue: Effects of long exposure times , 2001, Journal of magnetic resonance imaging : JMRI.

[38]  C. Damianou,et al.  Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part II. In vitro study. , 1996, The Journal of the Acoustical Society of America.

[39]  R. Seip,et al.  Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound , 1995, IEEE Transactions on Biomedical Engineering.

[40]  L A Crum,et al.  Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging. , 2001, Ultrasound in medicine & biology.