Environmental and occupational disorders Assessment of vacuum cleaners and vacuum cleaner bags recommended for allergic subjects

BACKGROUND High-quality vacuum cleaners and vacuum cleaner bags are often recommended to allergic patients as a means of reducing indoor allergen exposure. A number of vacuum cleaners on the market today claim to capture 99.9% of particles 0.3 microm or larger entering the vacuum cleaner, and many vacuum cleaner bags are now being sold as microfiltration bags. OBJECTIVE The purpose of this study was to compare the allergen-trapping abilities of vacuum cleaners and to use a new technique for testing vacuum cleaner bags that are recommended for allergic patients. METHODS Vacuum cleaners were tested in an 18-m(3) laboratory room permeated with dust containing high levels of cat allergen by using techniques previously described. Air was sampled with parallel filters in conjunction with a particle counter. The filters were assayed by ELISA for cat allergen (Fel d 1). Vacuum cleaner bags were tested by using a modified dust trap to pull sieved house dust containing a known amount of Fel d 1 across the material used for the bag. Allergen passing through the bag was trapped on a filter covering the exit of the trap and analyzed for Fel d 1. RESULTS In general, vacuum cleaners designed for allergic patients leaked lower amounts of allergen (<0.5-4.04 ng/m(3)) than that found in our previous studies (<0.5-100 ng/m(3)). Single-layer vacuum cleaner bags performed poorly (1250-2640 ng recovered) compared with most of the 2- and 3-layer microfiltration bags (0.53-2450 ng recovered). The range of allergen recovered from the 2-layer bags (0.93-2450 ng recovered) highlighted the variability found between manufacturers. CONCLUSION The results suggest that although allergen leakage has been reduced, there is still room for improvement. A method of testing allergen leakage by using Fel d 1 should be applied to vacuum cleaners and bags recommended for allergic patients.

[1]  M. Chapman,et al.  The effect of vacuum cleaners on the concentration and particle size distribution of airborne cat allergen. , 1993, The Journal of allergy and clinical immunology.

[2]  M. Ott,et al.  Effects of various vacuum cleaners on the airborne content of major cat allergen (Fel d 1) , 1998, Allergy.

[3]  N. Lefcoe,et al.  Particulates in domestic premises. I. Ambient levels and central air filtration. , 1971, Archives of environmental health.

[4]  T. Platts-Mills,et al.  Evaluation of materials used for bedding encasement: effect of pore size in blocking cat and dust mite allergen. , 1999, The Journal of allergy and clinical immunology.

[5]  M. Klauck,et al.  Correlations between levels of mite and cat allergens in settled and airborne dust. , 1989, The Journal of allergy and clinical immunology.

[6]  S. Tarlo Diisocyanate sensitization and antibody production. , 1999, The Journal of allergy and clinical immunology.

[7]  N. Lefcoe,et al.  Particulates in domestic premises. II. Ambient levels and indoor-outdoor relationships. , 1975, Archives of environmental health.

[8]  R. Einarsson,et al.  Vacuum cleaning decreases the levels of mite allergens in house dust , 1993, Pediatric allergy and immunology : official publication of the European Society of Pediatric Allergy and Immunology.

[9]  M. Chapman,et al.  A two-site monoclonal antibody ELISA for the quantification of the major Dermatophagoides spp. allergens, Der p I and Der f I. , 1989, Journal of immunological methods.

[10]  M. Chapman,et al.  Airborne concentrations and particle size distribution of allergen derived from domestic cats (Felis domesticus). Measurements using cascade impactor, liquid impinger, and a two-site monoclonal antibody assay for Fel d I. , 1990, The American review of respiratory disease.