submitter : A comparative study of the time performance between NINO and FlexToT ASICs

Universitat de Barcelona (UB) and CIEMAT have designed the FlexToT ASIC for the front-end readout of SiPM-based scintillator detectors. This ASIC is aimed at time of flight (ToF) positron emission tomography (PET) applications. In this work we have evaluated the time performance of the FlexToT v2 ASIC compared to the NINO ASIC, a fast ASIC developped at CERN. NINO electronics give 64 ps sigma for single-photon time resolution (SPTR) and 93 ps FWHM for coincidence time resolution (CTR) with 2 × 2 × 5 mm3 LSO:Ce,Ca crystals and S13360-3050CS SiPMs. Using the same SiPMs and crystals, the FlexToT v2 ASIC yields 91 ps sigma for SPTR and 123 ps FWHM for CTR. Despite worse time performace than NINO, FlexToT v2 features lower power consumption (11 vs. 27 mW/ch) and linear ToT energy measurement.

[1]  C. Piemonte,et al.  Characterization of the First FBK High-Density Cell Silicon Photomultiplier Technology , 2013, IEEE Transactions on Electron Devices.

[3]  K. Shimazoe,et al.  Time over Threshold based digital animal PET (TODPET) , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[4]  Paul Lecoq,et al.  Measurement of intrinsic rise times for various L(Y)SO and LuAG scintillators with a general study of prompt photons to achieve 10 ps in TOF-PET , 2016, Physics in medicine and biology.

[5]  Lluis Freixas,et al.  Evaluation of the FlexToT ASIC on the readout of SiPM matrices and scintillators for PET , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[6]  A. Blondel,et al.  Time of flight positron emission tomography towards 100 ps resolution with L ( Y ) SO : an experimental and theoretical analysis , 2017 .

[7]  E. Auffray,et al.  Time resolution deterioration with increasing crystal length in a TOF-PET system , 2014 .

[8]  P. Dorenbos,et al.  Scintillation Detector Timing Resolution; A Study by Ray Tracing Software , 2015, IEEE Transactions on Nuclear Science.

[9]  Albert Comerma Montells Development of a multichannel integrated circuit for Silicon Photo-Multiplier arrays readout , 2014 .

[10]  M. V. Nemallapudi,et al.  State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMs , 2016 .

[11]  Javier Castilla,et al.  FlexToT - Current mode ASIC for readout of common cathode SiPM arrays , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[12]  Ricardo Graciani,et al.  Performance of the FlexToT v2 ASIC on the readout of different detector designs for PET , 2015, 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).

[13]  Pierre Jarron,et al.  NINO: an ultra-fast and low-power front-end amplifier/discriminator ASIC designed for the multigap resistive plate chamber , 2004 .

[14]  T. Budinger Time-of-flight positron emission tomography: status relative to conventional PET. , 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  Benjamin Frisch,et al.  Time of flight positron emission tomography towards 100ps resolution with L(Y)SO: An experimental and theoretical analysis , 2013 .