Monte Carlo calculations on extremity and eye lens dosimetry for medical staff at interventional radiology procedures.

There are many factors that can influence the extremity and eye lens doses of the medical staff during interventional radiology and cardiology procedures. Numerical simulations can play an important role in evaluating extremity and eye lens doses in correlation with many different parameters. In the present study, the first results of the ORAMED (Optimisation of Radiation protection of MEDical staff) simulation campaign are presented. The parameters investigated for their influence on eye lens, hand, wrist and leg doses are: tube voltage, filtration, beam projection, field size and irradiated part of the patient's body. The tube voltage ranged from 60 to 110 kV(p), filtration from 3 to 6 mm Al and from 0 to 0.9 mm Cu. For all projections, the results showed that doses received by the operator decreased with increasing tube voltage and filtration. The magnitude of the influence of the tube voltage and the filtration on the doses depends on the beam projection and the irradiated part of the patient's body. Finally, the influence of the field size is significant in decreasing the doses.