A device for applying static loads to prosthetic limbs of transtibial amputees during spiral CT examination.

This paper describes a device that allows the imaging of prosthetic legs under load conditions using spiral computerized tomography (CT). The device consists of a chair and a vertical footplate mounted on a 17.8 x 1.9 cm oak board that is 197 cm long. The load device can be easily positioned onto the CT bed. A subject sits in the chair and applies force by pushing the foot portion of the prosthesis against the footplate. The magnitude of the force is monitored by a digital force gauge coupled to the footplate. Because the load is borne by the hips and lower back of the subject against the chair, substantial forces can be generated and steadily maintained for the 20-45 s duration of the CT study. This device has been used successfully with 19 transtibial amputees, allowing the acquisition of spiral CT studies with half and full body weight loads.

[1]  D G Smith,et al.  Socket considerations for the patient with a transtibial amputation. , 1999, Clinical orthopaedics and related research.

[2]  P K Commean,et al.  Below-knee residual limb shape change measurement and visualization. , 1998, Archives of physical medicine and rehabilitation.

[3]  P K Commean,et al.  Lower extremity residual limb slippage within the prosthesis. , 1997, Archives of physical medicine and rehabilitation.

[4]  W D Spence,et al.  Automatic segmentation of magnetic resonance images of the trans-femoral residual limb. , 1999, Medical engineering & physics.

[5]  G A Irwin,et al.  Prosthetic fit in below-knee amputation: evaluation with xeroradiography. , 1987, AJR. American journal of roentgenology.

[6]  P K Commean,et al.  Precision of surface measurements for below-knee residua. , 1996, Archives of physical medicine and rehabilitation.

[7]  H Hu,et al.  Multi-slice helical CT: scan and reconstruction. , 1999, Medical physics.

[8]  P He,et al.  A PC-based ultrasonic data acquisition system for computer-aided prosthetic socket design. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[9]  K. Taguchi,et al.  Algorithm for image reconstruction in multi-slice helical CT. , 1998, Medical physics.

[10]  J. Castellote,et al.  Videofluoroscopic evaluation of prosthetic fit and residual limbs following transtibial amputation. , 1998, Journal of rehabilitation research and development.

[11]  P K Commean,et al.  Residual-limb shape change: three-dimensional CT scan measurement and depiction in vivo. , 1996, Radiology.

[12]  P K Commean,et al.  Assessment of the diabetic foot using spiral computed tomography imaging and plantar pressure measurements: a technical report. , 2000, Journal of rehabilitation research and development.

[13]  P K Commean,et al.  Finite element modeling and experimental verification of lower extremity shape change under load. , 1997, Journal of biomechanics.