Kalman filter based incipient fault detection method for underground cables

An incipient and self-clearing arcing fault can be utilised as a precursor of an imminent permanent failure for monitoring of underground cables. Due to very short duration of the incipient faults, generally they cannot be detected by conventional protection relays. This study presents a new method for detection of incipient cable failures by using measured current and voltage at one end of the cable. The incipient faults are detected using an innovation signal calculated from the measured fault current via a Kalman filter. Upon change detection by the innovation signal, the change is checked for discriminating possible incipient fault from other similar conditions. The proposed method is evaluated using several simulations and field data collected from a real network. The results confirm that the method can achieve high accuracy and speed for detection of cables incipient faults.

[1]  Zhihan Xu,et al.  Detection of Incipient Faults in Distribution Underground Cables , 2010, IEEE Transactions on Power Delivery.

[2]  M. Sumner,et al.  A New Single-Ended Fault-Location Scheme for Utilization in an Integrated Power System , 2013, IEEE Transactions on Power Delivery.

[3]  Arturo S. Bretas,et al.  Fault location for underground distribution feeders: An extended impedance-based formulation with capacitive current compensation , 2009 .

[4]  K.L. Butler-Purry,et al.  Characterization of underground cable incipient behavior using time-frequency multi-resolution analysis and artificial neural networks , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[5]  B. Kasztenny,et al.  Detection of Incipient Faults in Underground Medium Voltage Cables , 2008, 2008 61st Annual Conference for Protective Relay Engineers.

[6]  Surya Santoso,et al.  Incipient Fault Location Algorithm for Underground Cables , 2014, IEEE Transactions on Smart Grid.

[7]  M. Paolone,et al.  Continuous-Wavelet Transform for Fault Location in Distribution Power Networks: Definition of Mother Wavelets Inferred From Fault Originated Transients , 2008, IEEE Transactions on Power Systems.

[8]  Hussain Shareef,et al.  Prediction of incipient faults in underground power cables utilizing S-transform and support vector regression , 2012 .

[9]  Arturo S. Bretas,et al.  Further improvements on impedance-based fault location for power distribution systems , 2011 .

[10]  M. I. Gilany,et al.  Traveling-Wave-Based Fault-Location Scheme for Multiend-Aged Underground Cable System , 2007 .

[11]  M. D. Judd,et al.  Fault location and diagnosis in a medium voltage EPR power cable , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[12]  Charles J. Kim,et al.  Sub-cycle ground fault location — Formulation and preliminary results , 2011, 2011 IEEE/PES Power Systems Conference and Exposition.

[13]  Javad Sadeh,et al.  A new and accurate fault location algorithm for combined transmission lines using Adaptive Network-Based Fuzzy Inference System , 2009 .

[14]  Zhihan Xu,et al.  Fault Location Method Based on Single-End Measurements for Underground Cables , 2011, IEEE Transactions on Power Delivery.

[15]  Charles Kim,et al.  An Initial Investigation for Locating Self-Clearing Faults in Distribution Systems , 2013, IEEE Transactions on Smart Grid.

[16]  L. A. Kojovic,et al.  Sub-cycle detection of incipient cable splice faults to prevent cable damage , 2000, 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134).

[17]  H. J. Li,et al.  Hotspot location and mitigation for underground power cables , 2005 .