Randomized comparison of simultaneous biventricular stimulation versus optimized interventricular delay in cardiac resynchronization therapy. The Resynchronization for the HemodYnamic Treatment for Heart Failure Management II implantable cardioverter defibrillator (RHYTHM II ICD) study.

BACKGROUND The clinical value of interventricular (V-V) delay optimization in patients with chronic congestive heart failure (CHF) undergoing implantation of a device for cardiac resynchronization therapy (CRT) has not been clearly demonstrated. METHODS RHYTHM II was a single-blind randomized trial including 121 recipients of a device for CRT with cardioverter/defibrillator capabilities (CRT-D) randomly assigned in a 1:3 ratio to simultaneous (n = 30) versus optimized (OPT) (n = 91) biventricular pacing. V-V delay was optimized by echocardiography. The study end points were (1) freedom from CRT-D system-related complications and (2) changes between preimplant and 6 months of follow-up in (a) New York Heart Association CHF functional class, (b) distance covered during a 6-minute hall walk, and (c) quality of life (QOL). RESULTS In the OPT group, the V-V delay ranged from 0 to 80 milliseconds, with 28.4% of patients stimulated at an OPT V-V delay of 0 milliseconds. The overall 6-month survival free of adverse events requiring invasive interventions was 81.8%. In the whole cohort, 6 months of CRT-D was associated with a significant decrease in New York Heart Association class, increase in the distance covered during the 6-minute hall walk, and improvement in QOL (each P < .0001). The effects of CRT-D on these end points were similar in both study groups. CONCLUSIONS Cardioverter-defibrillator capabilities was associated with a significant alleviation of CHF symptoms, increase in functional capacity, and improvement in QOL. The optimization of the V-V delay conferred no additional benefit compared with simultaneous biventricular stimulation.

[1]  R. Kerber,et al.  ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines). , 2002, Circulation.

[2]  Kevin Vernooy,et al.  Intra-ventricular resynchronization for optimal left ventricular function during pacing in experimental left bundle branch block. , 2003, Journal of the American College of Cardiology.

[3]  Bristow Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) : Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure , 2004 .

[4]  B. Kristensen,et al.  Sequential Versus Simultaneous Biventricular Resynchronization for Severe Heart Failure: Evaluation by Tissue Doppler Imaging , 2002, Circulation.

[5]  G. Boriani,et al.  Cardiac resynchronization by pacing: an electrical treatment of heart failure. , 2004, International journal of cardiology.

[6]  J. Jarcho Resynchronizing ventricular contraction in heart failure. , 2005, The New England journal of medicine.

[7]  Christophe Leclercq,et al.  Echocardiographic evaluation of cardiac resynchronization therapy: ready for routine clinical use? A critical appraisal. , 2004, Journal of the American College of Cardiology.

[8]  C. H. Chen,et al.  Improved left ventricular mechanics from acute VDD pacing in patients with dilated cardiomyopathy and ventricular conduction delay. , 1999, Circulation.

[9]  Lisa Hartling,et al.  Systematic Review: Cardiac Resynchronization in Patients with Symptomatic Heart Failure , 2004, Annals of Internal Medicine.

[10]  K. Ellenbogen,et al.  Resynchronization Therapy for the Treatment of Heart Failure , 2003, Circulation.

[11]  A. Hamer,et al.  Long‐Term Variations in Optimal Programming of Cardiac Resynchronization Therapy Devices , 2005, Pacing and clinical electrophysiology : PACE.

[12]  J. Daubert,et al.  Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. , 2001, The New England journal of medicine.

[13]  Albert Meijer,et al.  Effect of optimizing the VV interval on left ventricular contractility in cardiac resynchronization therapy. , 2004, The American journal of cardiology.

[14]  J. Mayet,et al.  Selection and optimisation of biventricular pacing: the role of echocardiography , 2004, Heart.

[15]  A. Auricchio,et al.  Cardiac resynchronization therapy: current state of the art: cost versus benefit. , 2004, Circulation.

[16]  D. DeMets,et al.  Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. , 2004, The New England journal of medicine.

[17]  Prashanthan Sanders,et al.  Echocardiographic parameters of ventricular dyssynchrony validation in patients with heart failure using sequential biventricular pacing. , 2004, Journal of the American College of Cardiology.

[18]  D. Hayes,et al.  Book Review Cardiac Resynchronization Therapy in Heart Failure , 2011 .

[19]  J. Daubert,et al.  The effect of cardiac resynchronization on morbidity and mortality in heart failure. , 2005, The New England journal of medicine.

[20]  T. Rector Patients' self-assessment of their congestive heart failure : Content, reliability, and validity of a new measure, the Minnesota Living with Heart Failure Questionnaire , 1987 .

[21]  A. Lazarus,et al.  Sequential Biventricular Pacing: , 2004, Pacing and clinical electrophysiology : PACE.

[22]  W. Braham,et al.  Cardiac Resynchronization in Chronic Heart Failure , 2002 .

[23]  M. Facchini,et al.  Simultaneous vs. sequential biventricular pacing in dilated cardiomyopathy: an acute hemodynamic study , 2003, European journal of heart failure.

[24]  Graham Nichol,et al.  Cost-Effectiveness of Cardiac Resynchronization Therapy in Patients with Symptomatic Heart Failure , 2004, Annals of Internal Medicine.