UNLABELLED
Indoor air organic compounds were continuously monitored during 3 years in new and older homes which were voluntarily selected throughout countries. The levels of volatile organic compounds (VOCs) in the new homes decreased markedly after 1 year, and steady emissions of VOCs were obtained in the initial months. Formaldehyde and a-pinene related to wooden materials need a longer flushing period than the other compounds in the new homes. The levels of the indoor air organic compounds in the older homes showed no significant fluctuation during the 3-year period. Decreases of the indoor-produced compounds in the new homes did not depend upon the ventilation systems. The results indicate that the indoor-produced compounds in the new homes will be more influenced by the aging decreases of emission source strengths than ventilation systems. The quantitative information on the trend of the indoor air organic compound levels will be useful for the risk assessment of indoor exposure to those compounds, and also for Japanese IAQ guidelines.
PRACTICAL IMPLICATIONS
The initial levels of VOCs in the new homes decreased dramatically and were close to the mean values for the older homes after one year. The results suggest that steady emissions of VOCs are obtained within initial months. However, formaldehyde and a-pinene did not follow the trend for VOCs, particularly in the wooden framed houses. The results tend to suggest that formaldehyde and a-pinene related to wooden materials will need more long a flushing period than other compounds in the new homes. Decreasing tendency of indoor air organic compound levels in the new homes did not appear to show any dependency upon the ventilation systems over the whole period. Absence of data for ventilation rates in the houses dose not permit interpretation of the relation between ventilation rates and indoor air organic compound levels with statistical certainty, but the results suggest that indoor air organic compound levels in the homes will be more influenced by emission source strengths than ventilation systems. The levels of indoor air organic compounds in the new homes are sufficiently decreased according to the ageing decreases of organic compounds when the home is ventilated with adequate quantities.
[1]
J. S. Park,et al.
Exposure to the mixtures of organic compounds in homes in Japan.
,
2004,
Indoor air.
[2]
Derrick Crump,et al.
Sources and Concentrations of Formaldehyde and Other Volatile Organic Compounds in the Indoor Air of Four Newly Built Unoccupied Test Houses
,
1997
.
[3]
D. Westerdahl,et al.
The Los Angeles TEAM Study: personal exposures, indoor-outdoor air concentrations, and breath concentrations of 25 volatile organic compounds.
,
1991,
Journal of exposure analysis and environmental epidemiology.
[4]
J S Park,et al.
Database system, AFoDas/AVODAS, on indoor air organic compounds in Japan. Automated Formaldehyde Data Acquisition System. Automated VOC Data Acquisition System.
,
2003,
Indoor air.
[5]
D. Gardiner,et al.
Measurement of volatile organic compounds in indoor air by a passive technique
,
1992
.
[6]
T. Reponen,et al.
The effect of material ageing and season on formaldehyde levels in different ventilation systems
,
1991
.
[7]
William J. Fisk,et al.
Effect of outside air ventilation rate on volatile organic compound concentrations in a call center
,
2003
.
[8]
S. Uchiyama,et al.
A sensitive diffusion sampler for the determination of volatile organic compounds in ambient air
,
1999
.
[9]
Christine Schulz,et al.
Seasonal variation of concentrations of volatile organic compounds in selected German homes
,
1989
.