Adaptive time-frequency analysis of knee joint vibroarthrographic signals for noninvasive screening of articular cartilage pathology

Vibroarthrographic (VAG) signals emitted by human knee joints are nonstationary and multicomponent in nature; time-frequency distributions (TFD's) provide powerful means to analyze such signals. The objective of this paper is to construct adaptive TFD's of VAG signals suitable for feature extraction. An adaptive TFD was constructed by minimum cross-entropy optimization of the TFD obtained by the matching pursuit decomposition algorithm. Parameters of VAG signals such as energy, energy spread. frequency, and frequency spread were extracted from their adaptive TFD's. The parameters carry information about the combined TF dynamics of the signals. The mean and standard deviation of the parameters were computed, and each VAG signal was represented by a set of just six features. Statistical pattern classification experiments based on logistic regression analysis of the parameters showed an overall normal/abnormal screening accuracy of 68.9% with 90 VAG signals (51 normals and 39 abnormals), and a higher accuracy of 77.5% with a database of 71 signals with 51 normals and 20 abnormals of a specific type of patellofemoral disorder. The proposed method of VAG signal analysis is independent of joint angle and clinical information, and shows good potential for noninvasive diagnosis and monitoring of patellofemoral disorders such as chondromalacia patella.

[1]  Rangaraj M. Rangayyan,et al.  Time-frequency signal feature extraction and screening of knee joint vibroarthrographic signals using the matching pursuit method , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[2]  R. Johnson,et al.  Properties of cross-entropy minimization , 1981, IEEE Trans. Inf. Theory.

[3]  A. Afifi,et al.  Statistical Analysis: A Computer Oriented Approach , 1979 .

[4]  P. P. Crump Statistical Analysis: A Computer Oriented Approach (2nd Ed.) , 1982 .

[5]  Les E. Atlas,et al.  Construction of positive time-frequency distributions , 1994, IEEE Trans. Signal Process..

[6]  S. Krishnan,et al.  Denoising knee joint vibration signals using adaptive time-frequency representations , 1999, Engineering Solutions for the Next Millennium. 1999 IEEE Canadian Conference on Electrical and Computer Engineering (Cat. No.99TH8411).

[7]  W. E. Blodgett,et al.  Auscultation of the Knee Joint , 1902 .

[8]  R M Rangayyan,et al.  Localization of knee joint cartilage pathology by multichannel vibroarthrography. , 1995, Medical engineering & physics.

[9]  Katherine Olivia Ladly Analysis of patellofemoral joint vibration signals , 1992 .

[10]  William J. Williams,et al.  Improved time-frequency representation of multicomponent signals using exponential kernels , 1989, IEEE Trans. Acoust. Speech Signal Process..

[11]  Y Nagata Joint-sounds in gonoarthrosis--clinical application of phonoarthrography for the knees. , 1988, Journal of UOEH.

[12]  Rodney W. Johnson,et al.  Axiomatic derivation of the principle of maximum entropy and the principle of minimum cross-entropy , 1980, IEEE Trans. Inf. Theory.

[13]  Jechang Jeong,et al.  Kernel design for reduced interference distributions , 1992, IEEE Trans. Signal Process..

[14]  Rangaraj M. Rangayyan,et al.  Detection of chirp and other components in the time-frequency plane using the Hough and Radon transforms , 1997, 1997 IEEE Pacific Rim Conference on Communications, Computers and Signal Processing, PACRIM. 10 Years Networking the Pacific Rim, 1987-1997.

[15]  R.M. Rangayyan,et al.  Analysis of knee vibration signals using linear prediction , 1992, IEEE Transactions on Biomedical Engineering.

[16]  R.M. Rangayyan,et al.  Adaptive cancellation of muscle contraction interference in vibroarthrographic signals , 1994, IEEE Transactions on Biomedical Engineering.

[17]  Stéphane Mallat,et al.  Matching pursuits with time-frequency dictionaries , 1993, IEEE Trans. Signal Process..

[18]  R.M. Rangayyan,et al.  Parametric representation and screening of knee joint vibroarthrographic signals , 1997, IEEE Transactions on Biomedical Engineering.

[19]  L. Cohen,et al.  Time-frequency distributions-a review , 1989, Proc. IEEE.

[20]  Sridhar Krishnan Adaptive signal processing techniques for analysis of knee joint vibroarthrographic signals , 1999 .

[21]  Leon Cohen,et al.  Positive time-frequency distribution functions , 1985, IEEE Trans. Acoust. Speech Signal Process..

[22]  R. Mollan,et al.  Vibration arthrography as a diagnostic aid in diseases of the knee. A preliminary report. , 1987, The Journal of bone and joint surgery. British volume.

[23]  Douglas L. Jones,et al.  A signal-dependent time-frequency representation: optimal kernel design , 1993, IEEE Trans. Signal Process..

[24]  Zahra M. K. Maussavi,et al.  Screening of vibroarthrographic signals via adaptive segmentation and linear prediction modeling , 1996, IEEE Transactions on Biomedical Engineering.

[25]  Boualem Boashash,et al.  Estimating and interpreting the instantaneous frequency of a signal. II. A/lgorithms and applications , 1992, Proc. IEEE.

[26]  Zhenyu Guo,et al.  The time-frequency distributions of nonstationary signals based on a Bessel kernel , 1994, IEEE Trans. Signal Process..

[27]  Rangaraj M. Rangayyan,et al.  Detection of nonlinear frequency-modulated components in the time-frequency plane using an array of accumulators , 1998, Proceedings of the IEEE-SP International Symposium on Time-Frequency and Time-Scale Analysis (Cat. No.98TH8380).

[28]  J Inoue,et al.  [Measurement of knee joint sounds by microphone]. , 1986, Journal of UOEH.