Improved optical axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography

We report on a new calibration technique that permits the accurate extraction of sample Jones matrix and hence fast-axis orientation by using fiber-based polarization-sensitive optical coherence tomography (PS-OCT) that is completely based on non polarization maintaining fiber such as SMF-28. In this technique, two quarter waveplates are used to completely specify the parameters of the system fibers in the sample arm so that the Jones matrix of the sample can be determined directly. The device was validated on measurements of a quarter waveplate and an equine tendon sample by a single-mode fiber-based swept-source PS-OCT system.

[1]  S. Matcher,et al.  Novel optical imaging technique to determine the 3-D orientation of collagen fibers in cartilage: variable-incidence angle polarization-sensitive optical coherence tomography. , 2009, Osteoarthritis and cartilage.

[2]  Barry Cense,et al.  Optic axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography. , 2005, Optics letters.

[3]  S. Matcher,et al.  Polarization-sensitive optical coherence tomography using continuous polarization modulation with arbitrary phase modulation amplitude. , 2012, Journal of biomedical optics.

[4]  S. Matcher A review of some recent developments in polarization-sensitive optical imaging techniques for the study of articular cartilage , 2009 .

[5]  Shuliang Jiao,et al.  Fiber-based polarization-sensitive Mueller-matrix optical coherence tomography with continuous source polarization modulation , 2004, SPIE BiOS.

[6]  Brett Bouma,et al.  Effects of sample arm motion in endoscopic polarization-sensitive optical coherence tomography. , 2005, Optics express.

[7]  J. Fujimoto,et al.  Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging , 1992 .

[8]  Toyohiko Yatagai,et al.  Phase retardation measurement of retinal nerve fiber layer by polarization-sensitive spectral-domain optical coherence tomography and scanning laser polarimetry. , 2008, Journal of biomedical optics.

[9]  Y. Yasuno,et al.  Polarization-sensitive swept-source optical coherence tomography with continuous source polarization modulation. , 2008, Optics express.

[10]  Barry Cense,et al.  Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components. , 2004, Optics letters.

[11]  Shuichi Makita,et al.  Full-range polarization-sensitive swept-source optical coherence tomography by simultaneous transversal and spectral modulation. , 2010, Optics express.

[12]  M. V. van Gemert,et al.  Two-dimensional birefringence imaging in biological tissue using polarization-sensitive optical coherence tomography , 1997, European Conference on Biomedical Optics.