Pulsatility Produced by the Hemodialysis Roller Pump as Measured by Doppler Ultrasound.

Microbubbles have previously been detected in the hemodialysis extracorporeal circuit and can enter the blood vessel leading to potential complications. A potential source of these microbubbles is highly pulsatile flow resulting in cavitation. This study quantified the pulsatility produced by the roller pump throughout the extracorporeal circuit. A Sonosite S-series ultrasound probe (FUJIFILM Sonosite Inc., Tokyo, Japan) was used on a single patient during normal hemodialysis treatment. The Doppler waveform showed highly pulsatile flow throughout the circuit with the greatest pulse occurring after the pump itself. The velocity pulse after the pump ranged from 57.6 ± 1.74 cm/s to -72 ± 4.13 cm/s. Flow reversal occurred when contact between the forward roller and tubing ended. The amplitude of the pulse was reduced from 129.6 cm/s to 16.25 cm/s and 6.87 cm/s following the dialyzer and venous air trap. This resulted in almost nonpulsatile, continuous flow returning to the patient through the venous needle. These results indicate that the roller pump may be a source of microbubble formation from cavitation due to the highly pulsatile blood flow. The venous air trap was identified as the most effective mechanism in reducing the pulsatility. The inclusion of multiple rollers is also recommended to offer an effective solution in dampening the pulse produced by the pump.

[1]  Yang Wang,et al.  A new computational fluid dynamics method for in-depth investigation of flow dynamics in roller pump systems. , 2014, Artificial organs.

[2]  N. Pliskin,et al.  Neurocognitive function in chronic hemodialysis patients. , 1996, Kidney international.

[3]  B. Stegmayr,et al.  Microbubbles of air may occur in the organs of hemodialysis patients. , 2012, ASAIO journal.

[4]  Michal Barak,et al.  Microbubbles : Pathophysiology and clinical implications , 2005 .

[5]  Ulf Forsberg,et al.  Development of air micro bubbles in the venous outlet line: an in vitro analysis of various air traps used for hemodialysis. , 2007, Artificial organs.

[6]  Ulf Forsberg,et al.  A high blood level in the air trap reduces microemboli during hemodialysis. , 2012, Artificial organs.

[7]  S. Deutsch,et al.  Observation and quantification of gas bubble formation on a mechanical heart valve. , 2000, Journal of biomechanical engineering.

[8]  Gholamreza Keshavarzi,et al.  Two-dimensional computational analysis of microbubbles in hemodialysis. , 2013, Artificial organs.

[9]  F Cusmano,et al.  Progression of cerebral atrophy in patients on regular hemodialysis treatment: long-term follow-up with cerebral computed tomography. , 1995, Nephron.

[10]  J. Rubin,et al.  Ultrasound detection of microembolic signals in hemodialysis accesses. , 2000, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[11]  H. Polaschegg Hemodialysis machine air detectors need not detect microbubbles. , 2007, Artificial organs.

[12]  A. Simmons,et al.  Investigation into the Existence of Cavitation within Haemodialysis Needles , 2014 .

[13]  P. Jonsson,et al.  Microemboli, developed during haemodialysis, pass the lung barrier and may cause ischaemic lesions in organs such as the brain. , 2010, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[14]  Léandre Pourcelot,et al.  Identification of microemboli during haemodialysis using Doppler ultrasound. , 2000, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[15]  Ulf Forsberg,et al.  Air bubbles pass the security system of the dialysis device without alarming. , 2007, Artificial organs.

[16]  T. Depner,et al.  Pressure effects on roller pump blood flow during hemodialysis. , 1990, ASAIO transactions.

[17]  P. Jonsson,et al.  The sensor in the venous chamber does not prevent passage of air bubbles during hemodialysis. , 2007, Artificial organs.

[18]  D. Hildick-Smith,et al.  Patent foramen ovale, dialysis and microembolization , 2012, Nephrology.

[19]  E. Ringelstein,et al.  Detection of microemboli in the subclavian vein of patients undergoing haemodialysis and haemodiafiltration using pulsed Doppler ultrasound. , 2002, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[20]  R. Fairshter,et al.  Lung pathology in chronic hemodialysis patients. , 1982, The International journal of artificial organs.