Self-Healing Capability of Fiber Reinforced Cementitious Composites

In order to investigate the self-healing capability of fibre reinforced cementitious composites (FRCC), mechanical properties and surface morphology of crack in FRCC were studied. Three types of FRCC specimens containing (1) polyethylene (PE) fibre, (2) steel cord (SC) fibre, and (3) hybrid fibres composite (both of PE and SC) were prepared. These specimens, in which cracks were introduced by tension test, were retained in water for 28 days. The self-healing capability of the specimens was investigated by means of microscope observation, water permeability test, tension test and backscattered electron image analysis. It was found that many very fine fibres of PE were bridging over the crack and crystallization products became easy to be attached to a large number of PE fibres. As a result, water permeability coefficient decreased and tensile strength was improved significantly. Therefore amount of the PE fibre per volume was indicated to have a great influence on self-healing. Furthermore, by means of backscattered electron image analysis, it was also shown that the difference of hydration degree in each FRCC has only little influence on the self-healing capability in case of the employed test series.

[1]  Matthew J. DeJong,et al.  The nanogranular behavior of C-S-H at elevated temperatures (up to 700 °C) , 2007 .

[2]  Mitsunori Kawamura,et al.  Analysis of cement pastes and mortars by a combination of backscatter-based SEM image analysis and calculations based on the Powers model , 2004 .

[3]  V. Li On Engineered Cementitious Composites (ECC) , 2003 .

[4]  A. Fantilli,et al.  A Cohesive Interface Model for the Pullout of Inclined Steel Fibers in Cementitious Matrixes , 2007 .

[5]  Yun Mook Lim,et al.  Feasibility study of a passive smart self-healing cementitious composite , 1998 .

[6]  Gilles Pijaudier-Cabot,et al.  Experimental characterization of the self-healing of cracks in an ultra high performance cementitious material: Mechanical tests and acoustic emission analysis , 2007 .

[7]  S. K. Kaushik,et al.  Confinement Reinforcement Design for Plain and Fibre Reinforced High Strength Concrete Columns , 2007 .

[8]  Wieland Ramm,et al.  Autogenous healing and reinforcement corrosion of water-penetrated separation cracks in reinforced concrete , 1998 .

[9]  V. Li,et al.  Simplified Inverse Method for Determining the Tensile Properties of Strain Hardening Cementitious Composites (SHCC) , 2008 .

[10]  Carola Edvardsen,et al.  Water Permeability and Autogenous Healing of Cracks in Concrete , 1999 .

[11]  V. Li,et al.  Practical Design Criteria for Saturated Pseudo Strain Hardening Behavior in ECC , 2006 .

[12]  V. Li On Engineered Cementitious Composites ( ECC ) A Review of the Material and Its Applications , 2003 .

[13]  Atsushi Kambayashi,et al.  Seismic Behavior of 200 MPa Ultra-High-Strength Steel-Fiber Reinforced Concrete Columns under Varying Axial Load , 2007 .

[14]  N. Belie,et al.  Self-healing of cracks in concrete , 2011 .

[15]  Hiroshi Fukuyama,et al.  Properties of Hybrid Fiber Reinforced Cement - based Composites , 2003 .

[16]  V. Li,et al.  Simplified Inverse Method for Determining the Tensile Strain Capacity of Strain Hardening Cementitious Composites , 2007 .

[17]  Micro-mechanical Analysis of Fiber Reinforced Cementitious Composites , 2006 .

[18]  Shunsuke Sugano,et al.  Study of New RC Structures Using Ultra-High-Strength Fiber-Reinforced Concrete (UFC)-The Challenge of Applying 200MPa UFC to Earthquake Resistant Building Structures:-The Challenge of Applying 200 MPa UFC to Earthquake Resistant Building Structures- , 2007 .

[19]  H. Reinhardt,et al.  Permeability and self-healing of cracked concrete as a function of temperature and crack width , 2003 .

[20]  En-Hua Yang,et al.  Fiber-Bridging Constitutive Law of Engineered Cementitious Composites , 2008 .