OBJECTIVE A novel method for the imaging of static scenes using electrical impedance tomography (EIT) is reported with implementation and validation using numerical and phantom models. The technique is applicable to regions featuring symmetry in the normal case, asymmetry in the presence of a perturbation, and where there is a known, frequency-dependent change in the electrical conductivity of the materials in the region. APPROACH The stroke diagnostic problem is used as a motivating sample application. The head is largely symmetrical across the sagittal plane. A haemorrhagic or ischaemic lesion located away from the sagittal plane will alter this natural symmetry, resulting in a symmetrical imbalance that can be detected using EIT. Specifically, application of EIT stimulation and measurement protocols at two distinct frequencies detects deviations in symmetry if an asymmetrically positioned lesion is present, with subsequent identification and localisation of the perturbation based on known frequency-dependent conductivity changes. Anatomically accurate computational models are used to demonstrate the feasibility of the proposed technique using different types, sizes, and locations of lesions with frequency-dependent (or independent) conductivity. Further, a realistic experimental head phantom is used to validate the technique using frequency-dependent perturbations emulating the key numerical simulations. MAIN RESULTS Lesion presence, type, and location are detectable using this novel technique. Results are presented in the form of images and corresponding robust quantitative metrics. Better detection is achieved for larger lesions, those further from the sagittal plane, and when measurements have a higher signal-to-noise ratio. SIGNIFICANCE Bi-frequency symmetry difference EIT is an exciting new modality of EIT with the ability to detect deviations in the symmetry of a region that occur due to the presence of a lesion. Notably, this modality does not require a time change in the region and thus may be used in static scenarios such as stroke detection.

[1]  Andy Adler,et al.  Electrical Impedance Tomography: Tissue Properties to Image Measures , 2017, IEEE Transactions on Biomedical Engineering.

[2]  Tracy R. Henderson,et al.  Simple metric for scaling motor threshold based on scalp-cortex distance: application to studies using transcranial magnetic stimulation. , 2005, Journal of neurophysiology.

[3]  M. Wintermark,et al.  Guidelines for the Early Management of Patients With Acute Ischemic Stroke: A Guideline for Healthcare Professionals From the American Heart Association/American Stroke Association , 2013, Stroke.

[4]  Simon Arridge,et al.  Stroke type differentiation using spectrally constrained multifrequency EIT: evaluation of feasibility in a realistic head model , 2014, Physiological measurement.

[5]  D. Djajaputra Electrical Impedance Tomography: Methods, History and Applications , 2005 .

[6]  S. Crozier,et al.  Design and Experimental Evaluation of a Non-Invasive Microwave Head Imaging System for Intracranial Haemorrhage Detection , 2016, PloS one.

[7]  Wuqiang Yang,et al.  Tomography for multi-phase flow measurement in the oil industry , 2005 .

[8]  James Avery,et al.  Multi-frequency electrical impedance tomography and neuroimaging data in stroke patients , 2018, Scientific Data.

[9]  Lior Horesh,et al.  Some novel approaches in modelling and image reconstruction for multi-frequency Electrical Impedance Tomography of the human brain , 2006 .

[10]  Priscilla Perez Russo,et al.  Asymmetry of Human Skull Base During Growth , 2011 .

[11]  Gregory Boverman,et al.  Detection of small bleeds in the brain with electrical impedance tomography , 2016, Physiological measurement.

[12]  Andreas Dedner,et al.  A Fast Parallel Solver for the Forward Problem in Electrical Impedance Tomography , 2015, IEEE Transactions on Biomedical Engineering.

[13]  A. Ehlis,et al.  Simulation of Near-Infrared Light Absorption Considering Individual Head and Prefrontal Cortex Anatomy: Implications for Optical Neuroimaging , 2011, PloS one.

[14]  A. Villringer,et al.  Stroke Magnetic Resonance Imaging Is Accurate in Hyperacute Intracerebral Hemorrhage: A Multicenter Study on the Validity of Stroke Imaging , 2004, Stroke.

[15]  Eung Je Woo,et al.  Validation of weighted frequency-difference EIT using a three-dimensional hemisphere model and phantom. , 2011, Physiological measurement.

[16]  James Avery,et al.  A Versatile and Reproducible Multi-Frequency Electrical Impedance Tomography System , 2017, Sensors.

[17]  Eung Je Woo,et al.  Multi-Frequency Electrical Impedance Tomography System With Automatic Self-Calibration for Long-Term Monitoring , 2014, IEEE Transactions on Biomedical Circuits and Systems.

[18]  D S Holder,et al.  Comparison of frequency difference reconstruction algorithms for the detection of acute stroke using EIT in a realistic head-shaped tank , 2012, Physiological measurement.

[19]  Brian McGinley,et al.  Symmetry difference electrical impedance tomography—a novel modality for anomaly detection , 2018, Physiological measurement.

[20]  James Avery,et al.  Reproducible 3D printed head tanks for electrical impedance tomography with realistic shape and conductivity distribution , 2017, Physiological measurement.

[21]  Karolinska Schizophrenia Mapping cortical brain asymmetry in 17,141 healthy individuals worldwide via the ENIGMA consortium , 2018 .

[22]  K R Lees,et al.  Acute stroke , 2000, BMJ : British Medical Journal.

[23]  J. Gomes,et al.  Types of Strokes , 2013 .

[24]  B H Brown,et al.  Electrical impedance tomography (EIT): a review , 2003, Journal of medical engineering & technology.

[25]  Brian McGinley,et al.  Stable tissue-mimicking materials and an anatomically realistic, adjustable head phantom for electrical impedance tomography , 2017 .

[26]  S. Hamilton EIT Imaging of admittivities with a D-bar method and spatial prior: experimental results for absolute and difference imaging , 2017, Physiological measurement.

[27]  Simon Arridge,et al.  A Reconstruction-Classification Method for Multifrequency Electrical Impedance Tomography , 2015, IEEE Transactions on Medical Imaging.

[28]  Andy Adler,et al.  Why is EIT so hard, and what are we doing about it? , 2015, Physiological measurement.

[29]  Lior Horesh,et al.  Stroke type differentiation by multi-frequency electrical impedance tomography—a feasibility study , 2005 .

[30]  Simon R. Arridge,et al.  Multifrequency Electrical Impedance Tomography Using Spectral Constraints , 2014, IEEE Transactions on Medical Imaging.

[31]  W. Powers,et al.  2018 Guidelines for the Early Management of Patients With Acute Ischemic Stroke: A Guideline for Healthcare Professionals From the American Heart Association/American Stroke Association , 2018, Stroke.