Vertical temperature profiles and borehole resistance in a U-tube borehole heat exchanger

The design of ground source heat pump systems requires values for the ground thermal conductivity and the borehole thermal resistance. In situ thermal response tests (TRT) are often performed on vertical boreholes to determine these parameters. Most TRT analysis methods apply the mean of the inlet and outlet temperatures of the circulating fluid along the entire borehole length. This assumption is convenient but not rigorous. To provide a more general approach, this paper develops an analytical model of the vertical temperature profile in the borehole during the late-time period of the in situ test. The model also includes the vertical temperature profile of the undisturbed ground. The model is verified with distributed temperature measurements along a vertical borehole using fiber optic cables inside a U-tube for the circulating fluid. The borehole thermal resistance is calculated without the need for the mean temperature approximation. In the studied borehole, the mean temperature approximation overestimates the borehole resistance by more than 20%.

[1]  Richard A. Beier,et al.  Vertical temperature profile in ground heat exchanger during in-situ test , 2011 .

[2]  Å. Melinder Thermophysical Properties of Aqueous Solutions Used as Secondary Working Fluids , 2007 .

[3]  Murray R. Spiegel,et al.  Applied Differential Equations , 1967 .

[4]  L. Gosselin,et al.  Borehole temperature evolution during thermal response tests , 2011 .

[5]  J. C. Jaeger,et al.  Conduction of Heat in Solids , 1952 .

[6]  Burkhard Sanner,et al.  Thermal Response Test - Current Status and World-Wide Application , 2005 .

[7]  D. Marcotte,et al.  On the estimation of thermal resistance in borehole thermal conductivity test , 2008 .

[8]  Youming Chen,et al.  An average fluid temperature to estimate borehole thermal resistance of ground heat exchanger , 2011 .

[9]  Z. Fang,et al.  Improvement in Modeling of Heat Transfer in Vertical Ground Heat Exchangers , 2004 .

[10]  J. P. Hartnett,et al.  Handbook of Heat Transfer Fundamentals (Second Edition) , 1986 .

[11]  Stanislaw Kajl,et al.  A review of methods to evaluate borehole thermal resistances in geothermal heat-pump systems , 2010 .

[12]  Göran Hellström,et al.  CFD-modelling of natural convection in a groundwater-filled borehole heat exchanger , 2010 .

[13]  S. Kavanaugh,et al.  Simulation and Experimental Verification of Vertical Ground-coupled Heat Pump Systems , 1985 .

[14]  René Lefebvre,et al.  A Review of Thermal Response Test Analysis Using Pumping Test Concepts , 2011, Ground water.

[15]  Hikari Fujii,et al.  An improved thermal response test for U-tube ground heat exchanger based on optical fiber thermometers , 2009 .

[16]  J Acuña Improvements of U-pipe borehole heat exchangers. Licentiate thesis. , 2010 .

[17]  Weibo Yang,et al.  A two-region simulation model of vertical U-tube ground heat exchanger and its experimental verification , 2009 .

[18]  José Acuña,et al.  Distributed Thermal Response Test on a U-Pipe Borehole Heat Exchanger , 2009 .

[19]  J. Spitler,et al.  In Situ Measurement of Ground Thermal Conductivity: A Dutch Perspective , 2002 .

[20]  P. Mogensen Fluid to duct wall heat transfer in duct system heat storages , 1983 .

[21]  Z. Fang,et al.  Heat transfer analysis of boreholes in vertical ground heat exchangers , 2003 .

[22]  José Acuña,et al.  Improvements of U-pipe Borehole Heat Exchangers , 2010 .

[23]  H. S. Carslow,et al.  Conduction of Heat in Solids, Second Edition , 1986 .

[24]  Hongxing Yang,et al.  Vertical-borehole ground-coupled heat pumps: A review of models and systems , 2010 .