Awake light-aided blind nasal intubation: prototype device.

BACKGROUND Limited mouth opening associated with unavailable or ineffective fibreoptic bronchoscope (FOB) is an intubation challenge. A light-aiding device may facilitate the blind nasal intubation. METHODS Awake blind nasal intubation was planned for 16 elective patients with inaccessible oral route (three children and 13 adults, ASA I-II). Topical anaesthesia for the supraglottis, glottis, and upper trachea was performed using prototype supraglottic topical anaesthesia device and cricothyroid injection of local anaesthesia. Hand-made light-aiding intubation device was used to help blind nasal intubation. Three attempts of blind nasal intubation (60 s each) were allowed, otherwise failure and FOB intubation were considered. During the procedure, heart rate, mean arterial pressure, and arterial oxygen saturation (Spa(o(2))) were measured. Temperature created at the bulb surface of the device was measured for 4 min duration, with and without exposing the bulb to oxygen flow of 6 litre min(-1). RESULTS All the patients were successfully intubated except one child. Time to intubate in adults was mean (sd) 52.7 (8.6) s. Spa(o(2)) showed significant difference between before and after procedural values. The maximum temperature recorded at the bulb surface was 46.8 (0.4) degrees C and 48.1 (0.8) degrees C with and without oxygen flow, respectively. CONCLUSIONS The device appeared to be a safe and cost-effective transillumination method for blind nasal intubation in difficult airways.

[1]  C. Artime,et al.  Chapter 11 – Preparation of the Patient for Awake Intubation , 2012 .

[2]  B. Mccloskey,et al.  The difficult airway in adult critical care , 2008, Critical care medicine.

[3]  R. Bingham,et al.  Airway management. , 2008, Pediatric clinics of North America.

[4]  C. Hagberg,et al.  The American Society of Anesthesiologists' Management of the Difficult Airway Algorithm and Explanation-Analysis of the Algorithm , 2007 .

[5]  O. Hung,et al.  Chapter 20 – Intubating Stylets , 2007 .

[6]  D. Morrison,et al.  Chapter 10 – Preparation of the Patient for Awake Intubation , 2007 .

[7]  A. Ovassapian,et al.  Chapter 18 – Fiberoptic Endoscopy—Aided Techniques , 2007 .

[8]  C. Hagberg Benumof's airway management : principles and practice , 2007 .

[9]  D. Rothenberg Clinical Anesthesia. 5th ed. , 2006 .

[10]  E. Motoyama,et al.  Chapter 10 – Induction of Anesthesia and Maintenance of the Airway in Infants and Children , 2006 .

[11]  O. Hung,et al.  Proper preparation of the Trachlight™ and endotracheal tube to facilitate intubation , 2006, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[12]  G. Fanelli,et al.  Monitored anesthesia care. , 2005, Minerva anestesiologica.

[13]  C. H. V. Castro,et al.  MONITORED ANESTHESIA CARE FOR AMBULATORY ANESTHESIA , 2005 .

[14]  J. Varon,et al.  The difficult airway in critical care , 2004 .

[15]  Hernán Charrís,et al.  Endotracheal intubation with a lightwand or a laryngoscope results in similar hemodynamic variations in patients with coronary artery disease , 2003, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[16]  Yung-Tai Chung,et al.  Blind nasotracheal intubation is facilitated by neutral head position and endotracheal tube cuff inflation in spontaneously breathing patients , 2003, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[17]  A. Shigematsu,et al.  A Comparison of Two Tracheal Intubation Techniques with Trachlight™ and Fastrach™ in Patients with Cervical Spine Disorders , 2002, Anesthesia and analgesia.

[18]  R. Favaro,et al.  Effective nasotracheal intubation using a modified transillumination technique , 2002, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[19]  M. Schreiner,et al.  Lighted Stylet Tracheal Intubation: A Review , 2000, Anesthesia and analgesia.

[20]  K. Hanaoka,et al.  Safety of a New Lightwand Device (Trachlight[trade mark sign]): Temperature and Histopathological Study , 1998, Anesthesia and analgesia.

[21]  M. Boussofara,et al.  [Management of difficult intubation in the operating room]. , 1998, La Tunisie medicale.

[22]  Peter J. Davis,et al.  Smith's Anesthesia For Infants And Children , 1996 .

[23]  O. Hung,et al.  Lightwand intubation: I — A new lightwand device , 1995, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[24]  M. C. Rogers,et al.  Principles and Practice of Anesthesiology , 1994 .

[25]  P. Mongan,et al.  Arytenoid dislocation with lighted stylet intubation: case report and retrospective review. , 1994, Anesthesia and analgesia.

[26]  R. Doherty Correct positioning of an endotracheal tube using a flexible lighted stylet: Stewart RD, Lacrosse A, Kaplan RM, et al Crit Care Med 18:97–99 Jan 1990 , 1990 .

[27]  R. Kaplan,et al.  Correct positioning of an endotracheal tube using a flexible lighted stylet , 1990, Critical care medicine.

[28]  C. Gonzalez,et al.  Cricoarytenoid subluxation: complication of blind intubation with a lighted stylet. , 1989, Ear, nose, & throat journal.

[29]  R. Vaughan,et al.  Difficulties in tracheal intubation , 1986, The Ulster Medical Journal.

[30]  T. H. Evans “Pretracheal” Nerve Tract , 1959 .

[31]  J. S. Lundy Anesthesia in children. , 1955, Texas state journal of medicine.

[32]  E. F. Sullivan Anesthesia for Children , 1929 .