Regional lung perfusion: assessment with partially parallel three-dimensional MR imaging.

PURPOSE To evaluate partially parallel three-dimensional (3D) magnetic resonance (MR) imaging for assessment of regional lung perfusion in healthy volunteers and patients suspected of having lung cancer or metastasis. MATERIALS AND METHODS Seven healthy volunteers and 20 patients suspected of having lung cancer or metastasis were examined with 3D gradient-echo MR imaging with partially parallel image acquisitions (fast low-angle shot 3D imaging; repetition time msec/echo time msec, 1.9/0.8; flip angle, 40 degrees; acceleration factor, two; number of reference k-space lines for calibration, 24; field of view, 500 x 440 mm; matrix, 256 x 123; slab thickness, 160 mm; number of partitions, 32; voxel size, 3.6 x 2.0 x 5.0 mm(3); acquisition time, 1.5 seconds) after administration of 0.1 mmol/kg of gadobenate dimeglumine. In volunteers, 3D MR perfusion data sets were assessed for topographic and temporal distribution of regional lung perfusion. Sensitivity, specificity, accuracy, and positive and negative predictive values for perfusion MR imaging for detecting perfusion abnormalities in patients were calculated, with conventional radionuclide perfusion scintigraphy as the standard of reference. Interobserver and intermodality agreement was determined by using kappa statistics. RESULTS Topographic analysis of lung perfusion in volunteers revealed a significantly higher signal-to-noise ratio (SNR) of up to 327% in gravity-dependent lung areas. Temporal analysis similarly revealed much shorter lag time to peak enhancement in gravity-dependent lung areas. In patients, perfusion MR imaging achieved high sensitivity (88%-94%), specificity (100%), and accuracy (90%-95%) for detection of perfusion abnormalities. Interobserver agreement (kappa = 0.86) was very good and intermodality agreement (kappa = 0.69-0.83) was good to very good for detection of perfusion defects. A significant difference (P <.0001) in SNR was observed between normally perfused lung (14 +/- 7 [SD]) and perfusion defects (7 +/- 4) in patients. CONCLUSION Partially parallel MR imaging with high spatial and temporal resolution allows assessment of regional lung perfusion and has high diagnostic accuracy for detecting perfusion abnormalities.

[1]  T. Iwasawa,et al.  Prediction of postoperative pulmonary function using perfusion magnetic resonance imaging of the lung , 2002, Journal of magnetic resonance imaging : JMRI.

[2]  E. Pauwels,et al.  Nuclear medicine procedures in lung cancer , 1999, European Journal of Nuclear Medicine.

[3]  M. Völk,et al.  Renal time-resolved MR angiography: quantitative comparison of gadobenate dimeglumine and gadopentetate dimeglumine with different doses. , 2001, Radiology.

[4]  K. Takeda,et al.  Pulmonary ventilation‐perfusion MR imaging in clinical patients , 2001, Journal of magnetic resonance imaging : JMRI.

[5]  R R Edelman,et al.  Pulmonary perfusion: Qualitative assessment with dynamic contrast‐enhanced MRI using ultra‐short TE and inversion recovery turbo FLASH , 1996, Magnetic resonance in medicine.

[6]  H. Svanholm,et al.  Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic , 1989, APMIS : acta pathologica, microbiologica, et immunologica Scandinavica.

[7]  Tilo Winkler,et al.  Topographical distribution of pulmonary perfusion and ventilation, assessed by PET in supine and prone humans. , 2002, Journal of applied physiology.

[8]  L R Schad,et al.  Separation of arteries and veins in 3D MR angiography using correlation analysis , 2000, Magnetic resonance in medicine.

[9]  J. Debatin,et al.  Intraindividual Comparison of Gadopentetate Dimeglumine, Gadobenate Dimeglumine, and Gadobutrol for Pelvic 3D Magnetic Resonance Angiography , 2003, Investigative radiology.

[10]  H. Shima,et al.  Effect of the rate of gadolinium injection on magnetic resonance pulmonary perfusion imaging , 2002, Journal of magnetic resonance imaging : JMRI.

[11]  H. Kauczor Radiologische Untersuchungen der Lungenventilation mittels Magnetresonanztomographie , 2000 .

[12]  H. Gudbjartsson,et al.  The rician distribution of noisy mri data , 1995, Magnetic resonance in medicine.

[13]  H. Shima,et al.  Detectability of pulmonary perfusion defect and influence of breath holding on contrast‐enhanced thick‐slice 2D and on 3D MR pulmonary perfusion images , 2001, Journal of magnetic resonance imaging : JMRI.

[14]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[15]  A Potthast,et al.  Normal and abnormal pulmonary ventilation: visualization at hyperpolarized He-3 MR imaging. , 1996, Radiology.

[16]  R. Edelman,et al.  Demonstration of gravity‐dependent lung perfusion with contrast‐enhanced magnetic resonance imaging , 1999, Journal of magnetic resonance imaging : JMRI.

[17]  M. Bock,et al.  Assessment of Gadobenate Dimeglumine for Magnetic Resonance Angiography: Phase I Studies , 2002, Investigative radiology.

[18]  R R Edelman,et al.  Quantitative assessment of pulmonary perfusion with dynamic contrast‐enhanced MRI , 1999, Magnetic resonance in medicine.

[19]  S. Lindahl,et al.  Pulmonary perfusion is more uniform in the prone than in the supine position: scintigraphy in healthy humans. , 1999, Journal of applied physiology.

[20]  John P Mugler,et al.  Emphysema: hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes--initial experience. , 2002, Radiology.

[21]  Hans-Ulrich Kauczor,et al.  Assessment of lung ventilation by MR imaging: current status and future perspectives , 2002, European Radiology.

[22]  P. Croisille,et al.  Lung perfusion demonstrated by contrast-enhanced dynamic magnetic resonance imaging. Application to unilateral lung transplantation. , 1997, Investigative radiology.

[23]  F Fazio,et al.  Clinical ventilation-perfusion scintigraphy. , 1981, Clinical physiology.