Two-body wear of dental restorative materials.

AIM The aim of this in vitro study was to determine the two-body wear resistance of modern direct dental restorative materials. METHODS Eight standardized specimens were prepared from 14 dental restorative materials (nano-, micro-, hybrid-, macrofilled composites; compomer, silorane, ormocer); a veneering composite (Sinfony) and enamel were used for reference. Vickers hardness (HV) and inorganic filler weight were determined. Specimens were subjected to mastication simulation using a mastication simulator (50 N, 1.2×10(5) cycles, 1.2 Hz) in a pin-on-block design and simultaneous thermal cycling (600 cycles, 5/55 °C, 2 min/cycle). Steatite balls were used as antagonists. Vertical substance and volume loss were determined using cast replicas and a 3D laser scanning device. Means and standard deviations were calculated, and statistical analysis was performed using one-way ANOVA and the Games-Howell test for post hoc analysis (α=.05). RESULTS HV ranged between 19 and 76; inorganic filler weight ranged between 44% and 88%. Significantly lowest vertical substance and volume loss were detected for the microfilled composite Heliomolar; enamel yielded similar vertical substance and volume loss. Intermediate wear was found for the other microfilled and hybrid composites as well as the silorane and the ormocers. Significantly highest wear was found for the macrofilled composite Quixfil and the compomer Compoglass F. DISCUSSION Within the limitations of an in vitro study, the findings indicate similar wear behaviour for silorane- and ormocer-based dental restorative materials. However, correlations between HV, filler content, and wear resistance were poor.

[1]  D. Bartlett,et al.  An up to 3-year randomized clinical study comparing indirect and direct resin composites used to restore worn posterior teeth. , 2006, The International journal of prosthodontics.

[2]  Klaus D Jandt,et al.  Future perspectives of resin-based dental materials. , 2009, Dental materials : official publication of the Academy of Dental Materials.

[3]  N. Moszner,et al.  Nanotechnology for dental composites , 2004 .

[4]  C H Gibbs,et al.  Occlusal forces during chewing and swallowing as measured by sound transmission. , 1981, The Journal of prosthetic dentistry.

[5]  T. Stolarski,et al.  Wear: mechanisms, manifestations and measurement. Report of a workshop. , 1996, Journal of dentistry.

[6]  Bart Van Meerbeek,et al.  Three-year randomized clinical trial to evaluate the clinical performance and wear of a nanocomposite versus a hybrid composite. , 2009, Dental materials : official publication of the Academy of Dental Materials.

[7]  P. Lambrechts,et al.  How to simulate wear? Overview of existing methods. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[8]  S D Heintze,et al.  Wear of ten dental restorative materials in five wear simulators--results of a round robin test. , 2005, Dental materials : official publication of the Academy of Dental Materials.

[9]  W. D’hoore,et al.  Long-term evaluation of extensive restorations in permanent teeth , 2003, Journal of dentistry.

[10]  J. V. Dijken Direct resin composite inlays/onlays: an 11 year follow-up. , 2000 .

[11]  G. Carlsson,et al.  An investigation of some factors associated with occlusal tooth wear in a selected high-wear sample. , 1993, Scandinavian journal of dental research.

[12]  J L Ferracane,et al.  Evaluation of composite wear with a new multi-mode oral wear simulator. , 1996, Dental materials : official publication of the Academy of Dental Materials.

[13]  S. Heo,et al.  A study of the effects of chewing patterns on occlusal wear. , 2001, Journal of oral rehabilitation.

[14]  J. Devaux,et al.  Characterization of nanofilled compared to universal and microfilled composites. , 2007, Dental materials : official publication of the Academy of Dental Materials.

[15]  U. Pallesen,et al.  Composite resin fillings and inlays. An 11-year evaluation , 2003, Clinical Oral Investigations.

[16]  M Rosentritt,et al.  Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[17]  A. Yap,et al.  Wear behavior of new composite restoratives. , 2004, Operative dentistry.

[18]  P M Marquis,et al.  Wear of three dental composites under different testing conditions. , 2002, Journal of oral rehabilitation.

[19]  P. Lambrechts,et al.  In vivo evaluation of four posterior composites: quantitative wear measurements and clinical behavior. , 1986, Dental materials : official publication of the Academy of Dental Materials.

[20]  R. Wassell,et al.  Hardness of model dental composites – the effect of filler volume fraction and silanation , 1999, Journal of materials science. Materials in medicine.

[21]  P. Rammelsberg,et al.  Wear of resin denture teeth by two-body contact. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[22]  S. Heintze How to qualify and validate wear simulation devices and methods. , 2006, Dental materials : official publication of the Academy of Dental Materials.

[23]  E. Bresciani,et al.  Clinical evaluation of two packable posterior composites: 2-year follow-up , 2006, Clinical Oral Investigations.

[24]  G. Christensen Remaining challenges with Class II resin-based composite restorations. , 2007, Journal of the American Dental Association.

[25]  C. Davidson,et al.  Effect of Abrasion Medium on Wear of Stress-bearing Composites and Amalgam in vitro , 1986, Journal of dental research.

[26]  C P Turssi,et al.  Filler features and their effects on wear and degree of conversion of particulate dental resin composites. , 2005, Biomaterials.

[27]  R. Hickel,et al.  Mechanical properties and wear behavior of light-cured packable composite resins. , 2000, Dental materials : official publication of the Academy of Dental Materials.

[28]  I. Krejci,et al.  Wear of ceramic inlays, their enamel antagonists, and luting cements. , 1993, The Journal of prosthetic dentistry.

[29]  R. Wassell,et al.  Wear characteristics in a two-body wear test. , 1994, Dental materials : official publication of the Academy of Dental Materials.

[30]  J. Ferracane,et al.  In vitro wear of resin-based materials--simultaneous corrosive and abrasive wear. , 2006, Journal of biomedical materials research. Part B, Applied biomaterials.

[31]  R. Wassell,et al.  A Two-body Frictional Wear Test , 1994, Journal of dental research.

[32]  J L Ferracane,et al.  In vitro Wear of Composite with Varied Cure, Filler Level, and Filler Treatment , 1997, Journal of dental research.

[33]  J. Ferracane,et al.  Wear and Marginal Breakdown of Composites with Various Degrees of Cure , 1997, Journal of dental research.

[34]  F. Yanikoglu,et al.  Selected characteristics of an Ormocer and a conventional hybrid resin composite. , 2004, Dental materials : official publication of the Academy of Dental Materials.

[35]  P. Lambrechts,et al.  Three-year randomised clinical trial to evaluate the clinical performance, quantitative and qualitative wear patterns of hybrid composite restorations , 2009, Clinical Oral Investigations.

[36]  G D Stafford,et al.  Masticatory function--a review of the literature. 1. The form of the masticatory cycle. , 1975, Journal of oral rehabilitation.

[37]  E. Lesaffre,et al.  Three-year follow-up of five posterior composites: SEM study of differential wear. , 1993, Journal of dentistry.

[38]  D. Watts,et al.  In vitro characterization of two laboratory-processed resin composites. , 2003, Dental materials : official publication of the Academy of Dental Materials.

[39]  G. Zappini,et al.  The relationship between physical parameters and wear of dental composites , 2007 .

[40]  B. Lim,et al.  Evaluation of wear resistance of dental resin composites with a 3D profilometer. , 2004, Journal of biomedical materials research. Part B, Applied biomaterials.

[41]  E. Swift,et al.  36-month clinical evaluation of two adhesives and microhybrid resin composites in Class I restorations. , 2008, American journal of dentistry.

[42]  W. Johnston,et al.  Evaluation of the wear resistance of new nanocomposite resin restorative materials. , 2008, The Journal of prosthetic dentistry.

[43]  P. Marquis,et al.  Potential countersample materials for in vitro simulation wear testing. , 2002, Dental materials : official publication of the Academy of Dental Materials.

[44]  K. Ludwig,et al.  Two-body wear of resin and ceramic denture teeth in comparison to human enamel. , 2008, Dental materials : official publication of the Academy of Dental Materials.