In situ detection of Bacillus anthracis spores using fully submersible, self-exciting, self-sensing PMN-PT/Sn piezoelectric microcantilevers.

In this study, we have demonstrated in situ, all-electrical detection of Bacillus anthracis (BA) spores using lead magnesium niobate-lead titanate/tin (PMN-PT/Sn) piezoelectric microcantilever sensors (PEMS) fabricated from PMN-PT freestanding films and electrically insulated with methyltrimethoxysilane (MTMS) coatings on the tin surface. Antibody specific to BA spore surface antigen was immobilized on the platinum electrode of the PMN-PT layer. In phosphate-buffered saline (PBS) solution, the PMN-PT/Sn PEMS exhibited quality (Q) values ranging from 50 to 75. The detection was carried out in a closed-loop flow cell with a liquid volume of 0.8 ml and a flow rate of 1 ml min(-1). It was shown that one sensor, "PEMS-A" (500 microm long, 800 microm wide, with a 22 microm thick PMN-PT layer, a 20 microm thick tin layer and a 1 +/- 0.5 x 10(-12) g Hz(-1) mass detection sensitivity) exhibited resonance frequency shifts of 2100 +/- 200, 1100 +/- 100 and 700 +/- 100 Hz at concentrations of 20,000, 2000, and 200 spores ml(-1) or 16,000, 1600, and 160 total spores, respectively. Additionally, "PEMS-B" (350 microm long, 800 microm wide, with an 8 microm thick PMN-PT layer, a 6 microm thick tin layer and a 2 +/- 1 x 10(-13) g Hz(-1) mass detection sensitivity) exhibited resonance frequency shifts of 2400 +/- 200, 1500 +/- 200, 500 +/- 150 and 200 +/- 100 Hz at concentrations of 20,000, 2000, 100, and 45 spores ml(-1) or 16,000, 1600, 80, and 36 total spores, respectively.

[1]  R. Zare,et al.  Optical detection of single molecules. , 1997, Annual review of biophysics and biomolecular structure.

[2]  M S Thakur,et al.  Regeneration of ethyl parathion antibodies for repeated use in immunosensor: a study on dissociation of antigens from antibodies. , 2004, Biosensors & bioelectronics.

[3]  Y. Fung,et al.  Self-assembled monolayers as the coating in a quartz piezoelectric crystal immunosensor to detect Salmonella in aqueous solution. , 2001, Analytical chemistry.

[4]  Wan Y. Shih,et al.  Methyltrimethoxysilane-insulated piezoelectric microcantilevers for direct, all-electrical biodetection in buffered aqueous solutions , 2006 .

[5]  Tanja Popovic,et al.  Investigation of Bioterrorism-Related Anthrax, United States, 2001: Epidemiologic Findings , 2002, Emerging infectious diseases.

[6]  Wan Y. Shih,et al.  Effect of length, width, and mode on the mass detection sensitivity of piezoelectric unimorph cantilevers , 2002 .

[7]  Tae Song Kim,et al.  Immunoassay of prostate-specific antigen (PSA) using resonant frequency shift of piezoelectric nanomechanical microcantilever. , 2005, Biosensors & bioelectronics.

[8]  B. L. Weeks,et al.  A microcantilever-based pathogen detector. , 2003, Scanning.

[9]  G. S. Wilson,et al.  Polymeric mercaptosilane-modified platinum electrodes for elimination of interferants in glucose biosensors. , 1996, Analytical chemistry.

[10]  Jonathan S. Colton,et al.  Influence of surface stress on the resonance behavior of microcantilevers , 2005 .

[11]  C. Mirkin,et al.  Array-Based Electrical Detection of DNA with Nanoparticle Probes , 2002, Science.

[12]  A. Gehring,et al.  Use of a light-addressable potentiometric sensor for the detection of Escherichia coli O157:H7. , 1998, Analytical biochemistry.

[13]  Hermann E. Gaub,et al.  Single molecule force spectrometer with magnetic force control and inductive detection , 1999 .

[14]  B. Rogers,et al.  Nanowatt chemical vapor detection with a self-sensing, piezoelectric microcantilever array , 2003 .

[15]  Thomas Thundat,et al.  Adsorption-induced surface stress and its effects on resonance frequency of microcantilevers , 1995 .

[16]  Maria Minunni,et al.  The Quartz Crystal Microbalance as Biosensor. A Status Report on Its Future , 1995 .

[17]  E. A. Wachter,et al.  Detection of mercury vapor using resonating microcantilevers , 1995 .

[18]  Y. Miyagi,et al.  Detection of occult tumor cells in peripheral blood from patients with small cell lung cancer by promoter methylation and silencing of the retinoic acid receptor-beta. , 2003, Oncology Report.

[19]  G. Sauerbrey Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung , 1959 .

[20]  Tae Song Kim,et al.  Label free novel electrical detection using micromachined PZT monolithic thin film cantilever for the detection of C-reactive protein. , 2004, Biosensors & bioelectronics.

[21]  H. Craighead,et al.  Single cell detection with micromechanical oscillators , 2001 .

[22]  Richard J. Colton,et al.  Biosensor based on force microscope technology , 1996 .

[23]  G. Sauerbrey,et al.  Use of quartz vibration for weighing thin films on a microbalance , 1959 .

[24]  Philip S Low,et al.  Detection of Bacillus subtilis spores using peptide-functionalized cantilever arrays. , 2006, Journal of the American Chemical Society.

[25]  I. Aksay,et al.  Simultaneous liquid viscosity and density determination with piezoelectric unimorph cantilevers , 2001 .

[26]  Jung Ho Park,et al.  In-situ quantitative analysis of a prostate-specific antigen (PSA) using a nanomechanical PZT cantilever. , 2004, Lab on a chip.

[27]  Geunbae Lim,et al.  A self-excited micro cantilever biosensor actuated by PZT using the mass micro balancing technique , 2006 .

[28]  J. E. Mattson,et al.  A Group-IV Ferromagnetic Semiconductor: MnxGe1−x , 2002, Science.

[29]  S. O’Day,et al.  Quantification of Circulating DNA in the Plasma and Serum of Cancer Patients , 2004, Annals of the New York Academy of Sciences.

[30]  T. Graczyk,et al.  Molecular Characterization ofCryptosporidium Oocysts in Samples of Raw Surface Water and Wastewater , 2001, Applied and Environmental Microbiology.

[31]  H. Rothuizen,et al.  Translating biomolecular recognition into nanomechanics. , 2000, Science.

[32]  W. Shih,et al.  Sheet geometry enhanced giant piezoelectric coefficients , 2006 .

[33]  Peter Kuhn,et al.  A rare-cell detector for cancer. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[34]  Wan Y. Shih,et al.  Mass detection sensitivity of piezoelectric cantilevers with a nonpiezoelectric extension , 2006 .

[35]  R. Atlas,et al.  Detection of Salmonella spp. in oysters by PCR , 1994, Applied and environmental microbiology.

[36]  Raj Mutharasan,et al.  In situ cell detection using piezoelectric lead zirconate titanate-stainless steel cantilevers , 2003 .

[37]  L. Harris,et al.  Reliable and Sensitive Identification of Occult Tumor Cells Using the Improved Rare Event Imaging System , 2004, Clinical Cancer Research.

[38]  S. Lindsay,et al.  A magnetically driven oscillating probe microscope for operation in liquids , 1996 .