Magnetic-field-induced dose effects in MR-guided radiotherapy systems: dependence on the magnetic field strength

Abstract:Several institutes are currently working on the development of a radiotherapy treatment system with online MR imaging (MRI) modality. The main difference between their designs is the magnetic field strength of the MRI system. While we have chosen a 1.5 Tesla (T) magnetic field strength, the Cross Cancer Institute in Edmonton will be using a 0.2 T MRI scanner and the company Viewray aims to use 0.3 T. The magnetic field strength will affect the severity of magnetic field dose effects, such as the electron return effect (ERE): considerable dose increase at tissue air boundaries due to returning electrons. This paper has investigated how the ERE dose increase depends on the magnetic field strength. Therefore, four situations where the ERE occurs have been simulated: ERE at the distal side of the beam, the lateral ERE, ERE in cylindrical air cavities and ERE in the lungs. The magnetic field comparison values were 0.2, 0.75, 1.5 and 3 T. Results show that, in general, magnetic field dose effects are reduced at lower magnetic field strengths. At the distal side, the ERE dose increase is largest for B = 0.75 T and depends on the irradiation field size for B = 0.2 T. The lateral ERE is strongest for B = 3 T but shows no effect for B = 0.2 T. Around cylindrical air cavities, dose inhomogeneities disappear if the radius of the cavity becomes small relative to the in-air radius of the secondary electron trajectories. At larger cavities (r > 1 cm), dose inhomogeneities exist for all magnetic field strengths. In water-lung-water phantoms, the ERE dose increase takes place at the water-lung transition and the dose decreases at the lung-water transition, but these effects are minimal for B = 0.2 T. These results will contribute to evaluating the trade-off between magnetic field dose effects and image quality of MR-guided radiotherapy systems.

参考文献

[1]  Tomas Kron,et al.  Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal , 2006, Journal of medical physics.

[2]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[3]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[4]  Ping Xia,et al.  Low-dose megavoltage cone-beam CT for radiation therapy. , 2005, International journal of radiation oncology, biology, physics.

[5]  J J W Lagendijk,et al.  Dose optimization for the MRI-accelerator: IMRT in the presence of a magnetic field , 2007, Physics in medicine and biology.

[6]  Jan J W Lagendijk,et al.  MRI/linac integration. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  B W Raaymakers,et al.  Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose increase at tissue–air interfaces in a lateral magnetic field due to returning electrons , 2005, Physics in medicine and biology.

[8]  A N T J Kotte,et al.  Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose deposition in a transverse magnetic field. , 2004, Physics in medicine and biology.

[9]  B W Raaymakers,et al.  Integrating a MRI scanner with a 6 MV radiotherapy accelerator: impact of the surface orientation on the entrance and exit dose due to the transverse magnetic field , 2007, Physics in medicine and biology.

[10]  S. Incerti,et al.  Geant4 developments and applications , 2006, IEEE Transactions on Nuclear Science.

[11]  Jan J W Lagendijk,et al.  Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  J. Lagendijk,et al.  MRI guided radiotherapy A MRI based linear accelerator , 2000 .

[13]  B W Raaymakers,et al.  Experimental verification of magnetic field dose effects for the MRI-accelerator , 2007, Physics in medicine and biology.

引用
Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy
Physics in medicine and biology
2018
MRI Linac Systems
MRI for Radiotherapy
2019
Magnetic resonance image guidance in external beam radiation therapy planning and delivery
Japanese Journal of Radiology
2017
SBRT targets that move with respiration.
Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics
2018
Minimal skin dose increase in longitudinal rotating biplanar linac-MR systems: examination of radiation energy and flattening filter design.
Physics in medicine and biology
2016
Radiation induced currents in MRI RF coils: application to linac/MRI integration.
Physics in medicine and biology
2010
The Potential for an Enhanced Role for MRI in Radiation-therapy Treatment Planning
Technology in cancer research & treatment
2013
The magnetic resonance imaging-linac system.
Seminars in radiation oncology
2014
Radiation dosimetry in magnetic fields with Farmer-type ionization chambers: determination of magnetic field correction factors for different magnetic field strengths and field orientations
Physics in medicine and biology
2017
Dosimetry for the MRI accelerator: the impact of a magnetic field on the response of a Farmer NE2571 ionization chamber
Physics in medicine and biology
2009
Deep Inspiration Breath Hold-Based Radiation Therapy: A Clinical Review.
International journal of radiation oncology, biology, physics
2016
Real-Time MRI-Guided Particle Therapy
MRI for Radiotherapy
2019
Magnetic Resonance Imaging-Guided Adaptive Radiation Therapy: A "Game Changer" for Prostate Treatment?
International journal of radiation oncology, biology, physics
2018
Image-guided radiation therapy: emergence of MR-guided radiation treatment (MRgRT) systems
Medical Imaging
2010
Charged particle transport in magnetic fields in EGSnrc
2016
Two-and-a-half-year clinical experience with the world's first magnetic resonance image guided radiation therapy system
Advances in radiation oncology
2017
Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System.
International journal of radiation oncology, biology, physics
2017
Dose enhancement in radiotherapy of small lung tumors using inline magnetic fields: A Monte Carlo based planning study.
Medical physics
2015
Effect of low magnetic field on single-diode dosimetry for clinical use.
Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics
2019
Impact of the MLC on the MRI field distortion of a prototype MRI-linac.
Medical physics
2013