Four-dimensional model of the lower extremity after total hip arthroplasty.
暂无分享,去创建一个
Naoki Suzuki | Nobuhiko Sugano | Asaki Hattori | Kazuo Yonenobu | Takahiro Ochi | Yoshito Otake | Keisuke Hagio
[1] C. Spoor,et al. Rigid body motion calculated from spatial co-ordinates of markers. , 1980, Journal of biomechanics.
[2] Philip C. Noble,et al. The Effect of Femoral Component Head Size on Posterior Dislocation of the Artificial Hip Joint* , 2000, The Journal of bone and joint surgery. American volume.
[3] B Jaramaz,et al. Image Guided Navigation System to Measure Intraoperatively Acetabular Implant Alignment , 1998, Clinical orthopaedics and related research.
[4] Gerald Q. Maguire,et al. Spatial component position in total hip arthroplasty. Accuracy and repeatability with a new CT method. , 2003, Acta radiologica.
[5] A. Duquennoy,et al. CAUSES OF DISLOCATION OF TOTAL HIP ARTHROPLASTY , 1994 .
[6] M. Seki,et al. Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer‐aided design simulation , 1998, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[7] J J O'Connor,et al. Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints. , 1999, Journal of biomechanics.
[8] Y. Ishii,et al. Three-dimensional kinematics of the human knee with intracortical pin fixation. , 1997, Clinical orthopaedics and related research.
[9] C Disselhorst-Klug,et al. A marker-based measurement procedure for unconstrained wrist and elbow motions. , 1999, Journal of biomechanics.
[10] D J Beard,et al. Reconstruction does not reduce tibial translation in the cruciate-deficient knee an in vivo study. , 2001, The Journal of bone and joint surgery. British volume.
[11] Michael Nogler,et al. No functional impairment after Robodoc total hip arthroplasty , 2002, Acta orthopaedica Scandinavica.
[12] E R Valstar,et al. A new model-based RSA method validated using CAD models and models from reversed engineering. , 2003, Journal of biomechanics.
[13] W. Bargar,et al. Primary and Revision Total Hip Replacement Using the Robodoc® System , 1998, Clinical orthopaedics and related research.
[14] R. Robinson,et al. Joint motion and surface contact area related to component position in total hip arthroplasty. , 1997, The Journal of bone and joint surgery. British volume.
[15] D. D’Lima,et al. The Effect of the Orientation of the Acetabular and Femoral Components on the Range of Motion of the Hip at Different Head-Neck Ratios* , 2000, The Journal of bone and joint surgery. American volume.
[16] Dinesh Manocha,et al. OBBTree: a hierarchical structure for rapid interference detection , 1996, SIGGRAPH.
[17] J Kärrholm,et al. Radiostereometry of hip prostheses. Review of methodology and clinical results. , 1997, Clinical orthopaedics and related research.
[18] Roger Y. Tsai,et al. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses , 1987, IEEE J. Robotics Autom..
[19] A Cappello,et al. Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics. , 1998, Journal of biomechanics.
[20] J Kärrholm,et al. Roentgen stereophotogrammetry. Review of orthopedic applications. , 1989, Acta orthopaedica Scandinavica.
[21] B F Morrey,et al. Dislocations after total hip arthroplasty. , 1982, The Journal of bone and joint surgery. American volume.
[22] Paul J. Besl,et al. A Method for Registration of 3-D Shapes , 1992, IEEE Trans. Pattern Anal. Mach. Intell..
[23] S. Delp,et al. Superior displacement of the hip in total joint replacement: Effects of prosthetic neck length, neck‐stem angle, and anteversion angle on the moment‐generating capacity of the muscles , 1994, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[24] K. Hagio,et al. Effectiveness of the ROBODOC system in preventing intraoperative pulmonary embolism , 2003, Acta orthopaedica Scandinavica.
[25] M P Kadaba,et al. Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[26] T J Koh,et al. In vivo tracking of the human patella. , 1992, Journal of biomechanics.
[27] B. Jaramaz,et al. Computer Assisted Measurement of Cup Placement in Total Hip Replacement , 1998, Clinical orthopaedics and related research.
[28] David W. Murray,et al. Reconstruction does not reduce tibial translation in the cruciate-deficient knee , 2001 .
[29] A. J. van den Bogert,et al. Effect of skin movement on the analysis of skeletal knee joint motion during running. , 1997, Journal of biomechanics.
[30] D A Dennis,et al. "In vivo" determination of hip joint separation and the forces generated due to impact loading conditions. , 2001, Journal of biomechanics.
[31] T P Andriacchi,et al. Correcting for deformation in skin-based marker systems. , 2001, Journal of biomechanics.
[32] Guoyan Zheng,et al. A hybrid CT-free navigation system for total hip arthroplasty. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.
[33] Hideki Yoshikawa,et al. Measurements of Pelvic Flexion Angle Using Three-Dimensional Computed Tomography , 2003, Clinical orthopaedics and related research.
[34] E R Valstar,et al. Model-based Roentgen stereophotogrammetry of orthopaedic implants. , 2001, Journal of biomechanics.
[35] L.-j. Yuan,et al. Dislocation after total hip arthroplasty , 1999, Archives of Orthopaedic and Trauma Surgery.