The effect of anteversion on femoral component stability assessed by radiostereometric analysis.

Internal rotation of a femoral stem within the femur, with posterior migration of the femoral head (PHM) relative to the femur, is an important mode of failure. The relationship between anteversion and rotational stability for the Exeter (Howmedica International Ltd, London, UK) and Charnley Elite (DePuy International Ltd, Leeds, UK) stems was investigated using radiostereometric analysis (RSA). For the Elite, there was a significant (P=.01) correlation between anteversion and PHM, whereas for the Exeter, there was no significant correlation (P=.6). Increasing anteversion of the Elite was associated with decreasing PHM and increased stability. Of stems, 20% of the Elite and none of the Exeter were classified as having reduced rotational stability because their PHM was >2 SDs from the mean. All reduced rotational stability implants had anteversion substantially <20 degrees. Polished collarless tapered stems such as the Exeter seem to have enhanced rotational stability. For conventional stems, increasing anteversion increases stability. It is recommended that these stems are anteverted 20 degrees.

[1]  D W Murray,et al.  Cement migration after THR. A comparison of charnley elite and exeter femoral stems using RSA. , 1999, The Journal of bone and joint surgery. British volume.

[2]  R. Brand,et al.  Comparison of hip force calculations and measurements in the same patient. , 1994, The Journal of arthroplasty.

[3]  D W Murray,et al.  Migration of cemented femoral components after THR. Roentgen stereophotogrammetric analysis. , 1996, The Journal of bone and joint surgery. British volume.

[4]  A. Cotten,et al.  Causes of dislocation of total hip arthroplasty. CT study of component alignment. , 1994, The Journal of bone and joint surgery. British volume.

[5]  H. Gill,et al.  Should total hip arthroplasty femoral components be designed to subside? A radiostereometric analysis study of the Charnley Elite and Exeter stems. , 2001, The Journal of arthroplasty.

[6]  D. Murray,et al.  Incomplete cement mantles in the sagittal femoral plane: an anatomical explanation. , 1999, Acta orthopaedica Scandinavica.

[7]  D W Murray,et al.  Roentgen Stereophotogrammetric Analysis for Assessing Migration of Total Hip Replacement Femoral Components , 1995, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  G Selvik,et al.  In vivo measurements of relative motion between an uncemented femoral total hip component and the femur by roentgen stereophotogrammetric analysis. , 1991, Clinical orthopaedics and related research.

[9]  D. W. Murray,et al.  Mid-term migration of a cemented total hip replacement assessed by radiostereometric analysis , 1999, International Orthopaedics.

[10]  D T Davy,et al.  Telemetric force measurements across the hip after total arthroplasty. , 1988, The Journal of bone and joint surgery. American volume.

[11]  G. Bergmann,et al.  Hip joint loading during walking and running, measured in two patients. , 1993, Journal of biomechanics.

[12]  J. Lewis,et al.  Dislocations after total hip-replacement arthroplasties. , 1978, The Journal of bone and joint surgery. American volume.

[13]  J. G. Andrews,et al.  A biomechanical investigation of the human hip. , 1978, Journal of biomechanics.

[14]  Harinderjit Gill,et al.  P066 A new hybrid video/digitiser based roentgen stereometric measurement system , 1998 .

[15]  Tingting Tang,et al.  [Measurement and classification of geometric parameters in Chinese proximal femur]. , 2002, Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi.

[16]  W H Harris,et al.  Femoral component loosening using contemporary techniques of femoral cement fixation. , 1982, The Journal of bone and joint surgery. American volume.

[17]  David W. Murray,et al.  Cement migration after THR , 1999 .

[18]  N. Rydell Forces acting on the femoral head-prosthesis. A study on strain gauge supplied prostheses in living persons. , 1966, Acta orthopaedica Scandinavica.

[19]  J. Kärrholm,et al.  Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. , 1994, The Journal of bone and joint surgery. British volume.

[20]  T. English,et al.  In vivo records of hip loads using a femoral implant with telemetric output (a preliminary report). , 1979, Journal of biomedical engineering.

[21]  T. Andriacchi,et al.  A study of lower-limb mechanics during stair-climbing. , 1980, The Journal of bone and joint surgery. American volume.

[22]  A Seireg,et al.  The prediction of muscular lad sharing and joint forces in the lower extremities during walking. , 1975, Journal of biomechanics.