Energy-Efficient Braking Torque Control of Robotic Transtibial Prosthesis

The ankle joint usually rotates passively during early and middle stance due to the locomotion of human body. Based on this passive dynamics of human locomotion, we develop an energy-efficient braking torque controller for a robotic transtibial prosthesis. The controller first generates motor current/torque from human locomotion instead of the battery energy, and then controls the current/torque with alternating current sensing and voltage-controlled-resistor. On the basis of the low-level motor torque controller, we then propose the impedance model that determines the desired joint torque according to the joint angle and joint velocity, the prosthesis model that converts the desired ankle joint torque to desired motor torque, and the friction model that estimates the friction torque and compensates the joint torque. Step response and frequency response show that the low-level controller can reach the desired torque value within 0.07 s, and has a <inline-formula><tex-math notation="LaTeX">$-$</tex-math></inline-formula>3 <inline-formula><tex-math notation="LaTeX">$\text{dB}$</tex-math></inline-formula> bandwidth of 25.2 <inline-formula> <tex-math notation="LaTeX">$\text{Hz}$</tex-math></inline-formula>. Experiments of level-ground treadmill walking with three amputees show that the prosthesis with the proposed controller can effectively mimic the normal ankle performance and bring the amputees a natural gait pattern with low power consumption.

[1]  Marco Liserre,et al.  An energy-based control for an n-H-bridges multilevel active rectifier , 2005, IEEE Transactions on Industrial Electronics.

[2]  Nilanjan Sarkar,et al.  FINITE STATE IMPEDANCE-BASED CONTROL OF A POWERED TRANSFEMORAL PROSTHESIS , 2006 .

[3]  Andrew H Hansen,et al.  Biomechanics of the ankle-foot system during stair ambulation: implications for design of advanced ankle-foot prostheses. , 2012, Journal of biomechanics.

[4]  D. Gobovic,et al.  A voltage controlled resistor in CMOS technology using bisection of the voltage range , 2000, Proceedings of the 17th IEEE Instrumentation and Measurement Technology Conference [Cat. No. 00CH37066].

[5]  Jun Morimoto,et al.  Variable Ankle Stiffness Improves Balance Control: Experiments on a Bipedal Exoskeleton , 2016, IEEE/ASME Transactions on Mechatronics.

[6]  Donald Lee Grimes An active multi-mode above knee prosthesis controller , 1979 .

[7]  R. Riener,et al.  Stair ascent and descent at different inclinations. , 2002, Gait & posture.

[8]  Juan Carlos Arevalo,et al.  An Adjustable Compliant Joint for Lower-Limb Exoskeletons , 2015, IEEE/ASME Transactions on Mechatronics.

[9]  Robert Riener,et al.  Actuator With Angle-Dependent Elasticity for Biomimetic Transfemoral Prostheses , 2015, IEEE/ASME Transactions on Mechatronics.

[10]  Michael Frederick Eilenberg,et al.  A neuromuscular-model based control strategy for powered ankle-foot prostheses , 2009 .

[11]  Samuel Kwok Wai Au,et al.  Powered ankle-foot prosthesis for the improvement of amputee walking economy , 2007 .

[12]  D. Winter,et al.  Biomechanics of below-knee amputee gait. , 1988, Journal of biomechanics.

[13]  Michael Goldfarb,et al.  Variable Cadence Walking and Ground Adaptive Standing With a Powered Ankle Prosthesis , 2016, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[14]  Paolo Bonato,et al.  Robotic Gait Rehabilitation Trainer , 2014, IEEE/ASME Transactions on Mechatronics.

[15]  S. Wolf,et al.  Biomechanical analysis of ramp ambulation of transtibial amputees with an adaptive ankle foot system. , 2010, Gait & posture.

[16]  C. D. Hoover,et al.  Stair Ascent With a Powered Transfemoral Prosthesis Under Direct Myoelectric Control , 2013, IEEE/ASME Transactions on Mechatronics.

[17]  Long Wang,et al.  Fuzzy-Logic-Based Terrain Identification with Multisensor Fusion for Transtibial Amputees , 2015, IEEE/ASME Transactions on Mechatronics.

[18]  Long Wang,et al.  Walk the Walk: A Lightweight Active Transtibial Prosthesis , 2015, IEEE Robotics & Automation Magazine.

[19]  Bram Vanderborght,et al.  Design and Validation of the Ankle Mimicking Prosthetic (AMP-) Foot 2.0 , 2014, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[20]  Giorgio Grioli,et al.  Variable Stiffness Actuators: Review on Design and Components , 2016, IEEE/ASME Transactions on Mechatronics.

[21]  T.G. Sugar,et al.  Control algorithms for ankle robots: A reflection on the state-of-the-art and presentation of two novel algorithms , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[22]  A. K. LaPre Semi-Active Damping for an Intelligent Adaptive Ankle Prosthesis , 2012 .

[23]  Hartmut Geyer,et al.  Control of a Powered Ankle–Foot Prosthesis Based on a Neuromuscular Model , 2010, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[24]  M. Louis CPG-based prostheses control , 2010 .

[25]  Hugh M. Herr,et al.  Powered Ankle--Foot Prosthesis Improves Walking Metabolic Economy , 2009, IEEE Transactions on Robotics.

[26]  R Jiménez-Fabián,et al.  Review of control algorithms for robotic ankle systems in lower-limb orthoses, prostheses, and exoskeletons. , 2012, Medical engineering & physics.

[27]  Michael Goldfarb,et al.  Design and Control of a Powered Transfemoral Prosthesis , 2008, Int. J. Robotics Res..

[28]  A. McIntosh,et al.  Gait dynamics on an inclined walkway. , 2006, Journal of biomechanics.

[29]  Long Wang,et al.  On the Design of a Powered Transtibial Prosthesis With Stiffness Adaptable Ankle and Toe Joints , 2014, IEEE Transactions on Industrial Electronics.

[30]  Blake Hannaford,et al.  Development of Powered Prosthetic Lower Limb , 1998 .

[31]  Thomas Sugar,et al.  Robotic transtibial prosthesis with biomechanical energy regeneration , 2009, Ind. Robot.

[32]  Long Wang,et al.  Adaptive Slope Walking With a Robotic Transtibial Prosthesis Based on Volitional EMG Control , 2015, IEEE/ASME Transactions on Mechatronics.

[33]  N. H. Molen Energy/speed relation of below-knee amputees walking on a motor-driven treadmill , 1973, Internationale Zeitschrift für angewandte Physiologie einschließlich Arbeitsphysiologie.