Identification of human joint mechanical properties from single trial data

A method is presented for estimating the time-varying compliance parameters of the elbow joint from a single movement. The method separates by frequency the perturbed from the voluntary response, then determines the parameters by exponentially weighted least squares. The tracking performance of the method is established by simulation and by a calibrated mechanical joint. Experimental results are presented on time-varying posture and slow movement.

[1]  Lennart Ljung,et al.  System Identification: Theory for the User , 1987 .

[2]  J. Lanman Movement and the mechanical properties of the intact human elbow joint. , 1980 .

[3]  P. Kumar,et al.  Theory and practice of recursive identification , 1985, IEEE Transactions on Automatic Control.

[4]  Graham C. Goodwin,et al.  Adaptive filtering prediction and control , 1984 .

[5]  Weiping Li,et al.  Applied Nonlinear Control , 1991 .

[6]  F Lacquaniti,et al.  Time-varying properties of myotatic response in man during some simple motor tasks. , 1981, Journal of neurophysiology.

[7]  R. Stein,et al.  Identification of intrinsic and reflex contributions to human ankle stiffness dynamics , 1997, IEEE Transactions on Biomedical Engineering.

[8]  I.W. Hunter,et al.  Identification of time-varying biological systems from ensemble data (joint dynamics application) , 1992, IEEE Transactions on Biomedical Engineering.

[9]  I.W. Hunter,et al.  An airjet actuator system for identification of the human arm joint mechanical properties , 1991, IEEE Transactions on Biomedical Engineering.

[10]  I W Hunter,et al.  System identification of human joint dynamics. , 1990, Critical reviews in biomedical engineering.

[11]  I. Hunter,et al.  Dynamics of human ankle stiffness: variation with mean ankle torque. , 1982, Journal of biomechanics.

[12]  Karl Johan Åström,et al.  Adaptive Control , 1989, Embedded Digital Control with Microcontrollers.

[13]  Y. Xu,et al.  Nonlinear time-varying identification of human arm joint mechanical properties using a portable pneumatic thruster , 1997, Proceedings of the 1997 American Control Conference (Cat. No.97CH36041).

[14]  I. Hunter,et al.  Dynamics of human ankle stiffness: variation with displacement amplitude. , 1982, Journal of biomechanics.

[15]  I. W. Hunter,et al.  Time-varying Identification Of Elbow Joint Dynamics Using Exponentially Weighted Least Squares , 1991, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991.

[16]  J. M. Hollerbach,et al.  Design and calibration of a 2D airjet device for human motor control study , 1995, Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society.