Passive Haptic Interface with MR-Brakes for Dental Implant Surgery

In this research a passive haptic interface is explored as a surgical aid for dental implant surgery. The placement of a dental implant is critical since positioning mistakes can lead to permanent damage in the nerves controlling the lips, long lasting numbness, and failure of the implant and the crown on it. Haptic feedback to the surgeon in real time can decrease dependence on the surgeon's skill and experience for accurate implant positioning and increase the overall safety of the procedure. The developed device is a lightweight mechanism with weight compensation. Rotary magnetorheological (MR) brakes were custom designed for this application using the serpentine flux path concept. The resulting MR-brakes are 33% smaller in diameter than the only commercially available such brakes, yet produce 2.7 times more torque at 10.9 Nm. Another contribution of this research was a ferro-fluidic sealing technique which decreased the off-state torque. The control system implemented the passive force manipulability ellipsoid algorithm for force rendering of rigid wall-following tasks. Usability experiments were conducted to drill holes with haptic feedback. The maximum average positioning error was 2.88 mm along the x axis. The errors along the y and z axes were 1.9 mm and 1.16 mm, respectively. The results are on the same order of magnitude as other dental robotic systems. The innovative new MR-brake actuators, inherent safety of the system, and simplicity of control make this passive haptic interface a viable option for further exploration.

[1]  김문상,et al.  Energy-based control of a passive haptic device , 2004 .

[2]  Hakan Gurocak,et al.  Spherical Brake with MR Fluid as Multi Degree of Freedom Actuator for Haptics , 2009 .

[3]  Kunal Lal,et al.  Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. The concept. , 2006, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[4]  Myeong-Kwan Park,et al.  Performance Improvement of a Rotary MR Fluid Actuator Based on Electromagnetic Design , 2008 .

[5]  Junji Furusho,et al.  Passive force display using ER brakes and its control experiments , 2001, Proceedings IEEE Virtual Reality 2001.

[6]  Predrag Sukovic,et al.  Accuracy of implant placement with a stereolithographic surgical guide. , 2003, The International journal of oral & maxillofacial implants.

[7]  Jörg Raczkowsky,et al.  Robot Assistant for Dental Implantology , 2001, MICCAI.

[8]  Rudolf Seemann,et al.  Computer-aided navigation in dental implantology: 7 years of clinical experience. , 2004, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[9]  L. Ellies,et al.  Altered sensation following mandibular implant surgery: a retrospective study , 1993 .

[10]  Munsang Kim,et al.  Direct Control of a Passive Haptic Device Based on Passive Force Manipulability Ellipsoid Analysis , 2004 .

[11]  Weihua Li,et al.  Design and Experimental Evaluation of a Magnetorheological Brake , 2003 .

[12]  Urs C Belser,et al.  Optimizing esthetics for implant restorations in the anterior maxilla: anatomic and surgical considerations. , 2004, The International journal of oral & maxillofacial implants.

[13]  Hakan Gurocak,et al.  Compact MR-brake with serpentine flux path for haptics applications , 2009, World Haptics 2009 - Third Joint EuroHaptics conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems.

[14]  A. Hein,et al.  A surgical robot system for maxillofacial surgery , 1998, IECON '98. Proceedings of the 24th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.98CH36200).

[15]  R A Kraut,et al.  The incidence of altered sensation of the mental nerve after mandibular implant placement. , 1999, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[16]  Wayne J. Book,et al.  Modeling and control of an improved dissipative passive haptic display , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[17]  Shinichi Yamada,et al.  Application of virtual reality force feedback haptic device for oral implant surgery. , 2006, Clinical oral implants research.

[18]  I. Nasseh,et al.  Lingual paresthesia following surgical placement of implants: report of a case. , 1993, The International journal of oral & maxillofacial implants.

[19]  Dong-Soo Kwon,et al.  Stability and Performance of Haptic Interfaces with Active/Passive Actuators—Theory and Experiments , 2006, Int. J. Robotics Res..

[20]  Jean Loup Coudert,et al.  An image-guided system-drilled surgical template and trephine guide pin to make treatment of completely edentulous patients easier: a clinical report on immediate loading. , 2004, Clinical implant dentistry and related research.

[21]  Barkan M. Kavlicoglu,et al.  A high-torque magneto-rheological fluid clutch , 2002 .

[22]  H Bergmann,et al.  In-vitro assessment of a registration protocol for image guided implant dentistry. , 2001, Clinical oral implants research.

[23]  Oussama Khatib,et al.  The haptic display of complex graphical environments , 1997, SIGGRAPH.

[24]  Scott D. Ganz Computer-Guided Surgery Utilizing a Computer-Milled Surgical Template , 2001 .

[25]  R Jacobs,et al.  Localisation of the mandibular canal using conventional spiral tomography: a human cadaver study. , 2001, Clinical oral implants research.

[26]  Georg Eggers,et al.  Accuracy of image-guided implantology. , 2005, Clinical oral implants research.

[27]  J. Blake,et al.  Haptic Glove With MR Brakes for Virtual Reality , 2009, IEEE/ASME Transactions on Mechatronics.

[28]  Dong-Soo Kwon,et al.  Haptic experimentation on a hybrid active/passive force feedback device , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[29]  Kunal Lal,et al.  Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part II. A clinical report. , 2006, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[30]  Björn Klinge,et al.  A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years. , 2002, Journal of clinical periodontology.

[31]  Myeong-Kwan Park,et al.  A hybrid haptic device for wide-ranged force reflection and improved transparency , 2007, 2007 International Conference on Control, Automation and Systems.