Electronic Design of a Semi-Automated Micromanipulator Cell Injection System

A cell microinjection system is a widely used tool in the domain of cell biology and it allows us to deliver a specific amount of substance into a cell using a fine tipped needle (or a microinjection pipette) under the observation of a microscope. Cell microinjection systems are widely used for delivering drugs to a single cell for the treatment of diseases, like Cancer, Alzheimer's, Sickle cell anemia and Cystic fibrosis etc., developing organs, like heart, lungs and kidney, and in-vitro fertilization. This paper surveys the state-of-the-art microinjection techniques and cell microinjections systems and proposes an electronic design for the semi-automated micro cell injection system, which works on the principle of capillary pressure microinjection (CPM). The distinguishing feature of the proposed system is its low cost without compromising on the accuracy or movement precision.

[1]  Xin Zhao,et al.  Robotic Cell Rotation Based on the Minimum Rotation Force , 2015, IEEE Transactions on Automation Science and Engineering.

[2]  Darwin G. Caldwell,et al.  A Fully Automated System for Adherent Cells Microinjection , 2014, IEEE Journal of Biomedical and Health Informatics.

[3]  Ken Chen,et al.  Mechanical behavior of cells in microinjection: a minimum potential energy study. , 2013, Journal of the mechanical behavior of biomedical materials.

[4]  Z. Xi,et al.  Blockade of dopamine D3 receptors in the nucleus accumbens and central amygdala inhibits incubation of cocaine craving in rats , 2013, Addiction biology.

[5]  G. Borisy,et al.  Components of a microinjection system. , 2011, Cold Spring Harbor protocols.

[6]  A. Tzes,et al.  Modelling and Adaptive Control of Nanowire-Driven Micromanipulators , 2011, J. Intell. Robotic Syst..

[7]  Haibo Huang,et al.  Robotic Cell Injection System With Position and Force Control: Toward Automatic Batch Biomanipulation , 2009, IEEE Transactions on Robotics.

[8]  Erlend Hodneland,et al.  A Unified Framework for Automated 3-D Segmentation of Surface-Stained Living Cells and a Comprehensive Segmentation Evaluation , 2009, IEEE Transactions on Medical Imaging.

[9]  Long-chuan Yu,et al.  Microinjection as a tool of mechanical delivery. , 2008, Current opinion in biotechnology.

[10]  Peter C. Y. Chen,et al.  A micromanipulation system with dynamic force-feedback for automatic batch microinjection , 2007 .

[11]  Edward Grant,et al.  Semi-automated blastocyst microinjection , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[12]  P. Kallio,et al.  Challenges in capillary pressure microinjection , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  Byung-Hwan Lee,et al.  Prevention of Ginsenoside-induced Desensitization of Ca2+-activated Cl– Current by Microinjection of Inositol Hexakisphosphate in Xenopus laevis Oocytes , 2004, Journal of Biological Chemistry.

[14]  김병규,et al.  Mechanical Force Response of Single Living Cells using a Microrobotic System , 2004 .

[15]  Russell H. Taylor,et al.  Preliminary experiments in robot/human cooperative microinjection , 2003, Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453).

[16]  G. Rubin,et al.  Genetic transformation of Drosophila with transposable element vectors. , 1982, Science.

[17]  M. Wickens,et al.  Expression of cloned genes in cell-free systems and in microinjected Xenopus oocytes , 1981 .