Magnetorheological damper–based positioning system with power generation

This study investigates a newly developed positioning system based on a rotary magnetorheological damper with power generation capability, comprising an electromagnetic power generator (energy extractor) generating electrical power, an magnetorheological damper which alters the damping characteristics of the system and an electrical interface, connected in between the coil of the generator and the damper control coil, which conditions the voltage output from the generator. Structural configurations of the damper and the generator are outlined, and the results of their testing and the testing done on the entire system are summarised, covering the tests conducted with and without the interface, under the idle run and under load in the assumed velocity range. The objective of the work is to examine the performance of the proposed positioning system through experiments. Results of the system testing in the uncontrolled case (passive system) and in the controlled one (semi-active system) in a purpose-built test rig are compared and discussed. Three design options of the electrical system controlling the damper are explored. In the first option, the damper is assumed to be controlled starting from the initial moment of the motor shaft’s motion, and in the second option, the control action begins at the instant when the motor shaft assumes the present position. The third variant is similar to the first one except that an additional condenser is connected behind the Graetz bridge. The results confirm the adequacy of the developed positioning system and demonstrate an improvement in control of the system’s dynamic behaviour.

[1]  Oussama Khatib,et al.  Motor vs. Brake: Comparative Studies on Performance and Safety in Hybrid Actuations , 2012, ISER.

[2]  Mark R. Jolly Pneumatic motion control using magnetorheological technology , 2001, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[3]  Guoyu Meng,et al.  Study of the Vibration Control of a Rotor System Using a Magnetorheological Fluid Damper , 2005 .

[4]  B. Sapiński Experimental study of a self-powered and sensing MR-damper-based vibration control system , 2011 .

[5]  Shiwu Zhang,et al.  A seat suspension with a rotary magnetorheological damper for heavy duty vehicles , 2016 .

[6]  Maciej Rosół,et al.  Implementation of the LQG controller for a wind turbine tower-nacelle model with an mr tuned vibration absorber , 2016 .

[7]  Jan Swevers,et al.  Vibration and motion control design and trade-off for high-performance mechatronic systems , 2006, 2006 IEEE Conference on Computer Aided Control System Design, 2006 IEEE International Conference on Control Applications, 2006 IEEE International Symposium on Intelligent Control.

[8]  Robert Konowrocki,et al.  ON THE SEMI-ACTIVE CONTROL METHOD FOR TORSIONAL VIBRATIONS IN ELECTRO-MECHANICAL SYSTEMS BY MEANS OF ROTARY ACTUATORS WITH A MAGNETO-RHEOLOGICAL FLUID , 2013 .

[9]  G. Tang,et al.  Motion Planning for Vibration Reducing of Free-floating Redundant Manipulators Based on Hybrid Optimization Approach , 2011 .

[10]  Mohd Fitri Mohd Yakub,et al.  Improved NCTF Control Method for a Two-Mass Rotary Positioning Systems , 2011 .

[11]  J Gołdasz,et al.  Parametric study on the performance of automotive MR shock absorbers , 2016 .

[12]  Wan Kyun Chung,et al.  Motion control of precision positioning systems using adaptive compensation , 2002, Proceedings of the 2002 American Control Conference (IEEE Cat. No.CH37301).

[13]  Felix Weber,et al.  Semi-Active TMD Concept for Volgograd Bridge , 2013 .

[14]  Peyman Yadmellat,et al.  Design and Development of a Single-Motor, Two-DOF, Safe Manipulator , 2014, IEEE/ASME Transactions on Mechatronics.

[15]  Hiroki Tomori,et al.  The position and vibration control of the artificial muscle manipulator by variable viscosity coefficient using MR brake , 2011, IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society.

[16]  Jie Zhao,et al.  A rotary magnetorheological fluid damper for pathological tremor suppression , 2012, 2012 IEEE International Conference on Mechatronics and Automation.

[17]  Masao Tanaka,et al.  An Ankle-Foot Orthosis with a Variable-Resistance Ankle Joint Using a Magnetorheological-Fluid Rotary Damper , 2009 .

[18]  Onur Avci,et al.  Active vibration control of flexible cantilever plates using piezoelectric materials and artificial neural networks , 2016 .

[19]  Taro Nakamura,et al.  Variable impedance control with an artificial muscle manipulator using instantaneous force and MR brake , 2013, 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[20]  L. Zuo,et al.  Energy-harvesting shock absorber with a mechanical motion rectifier , 2013 .

[21]  Hyung-Jo Jung,et al.  Feasibility study of an MR damper-based smart passive control system employing an electromagnetic induction device , 2007 .

[22]  Marc Thomas,et al.  Control of torsional rotor vibrations using an electrorheological fluid dynamic absorber , 2011 .

[23]  Bogdan Sapiński,et al.  Energy-harvesting linear MR damper: prototyping and testing , 2014 .

[24]  Zhongsheng Sun,et al.  Pneumatic servo rotary actuator with a MRF-damper , 2011, Proceedings of 2011 International Conference on Fluid Power and Mechatronics.

[25]  Jen-Yuan Chang,et al.  Development of magnetorheological fluid clutch for robotic arm applications , 2016, 2016 IEEE 14th International Workshop on Advanced Motion Control (AMC).

[26]  Shuaishuai Sun,et al.  Development of a self-sensing magnetorheological damper with magnets in-line coil mechanism , 2017 .

[27]  Wei-Hsin Liao,et al.  An integrated relative displacement self-sensing magnetorheological damper: prototyping and testing , 2010 .

[28]  Bogdan Sapiński,et al.  Energy balance in self-powered MR damper-based vibration reduction system , 2011 .