Adaptive predictive control of dissolved oxygen concentration in a laboratory-scale bioreactor.

We present an algorithm for the adaptive control of dissolved oxygen concentration in a bioreactor, based on the agitation rate. The dynamics are represented by an incremental first-order model with variable dead-time and parameters. These are estimated on-line by a recursive least-squares identification method with a forgetting factor and a constant sensitivity. The model is employed to predict the behaviour of the dissolved oxygen concentration over a finite horizon, using an original method which requires little computation. Then, a Generalized Predictive Control optimisation strategy computes the agitation rate from the predictions and the desired set point, while gradually updating the controller smoothness. This algorithm, which requires little preliminary knowledge, has been implemented on a laboratory-scale fed-batch bioreactor for which the use of conventional controllers showed limited performance, due to the unpredictable and evolutive nature of the dynamics. The new controller proved to be robust and effective over a wide range of operating conditions, while requiring no operator adjustments.

[1]  Irving J. Dunn,et al.  Measurement and Control of Dissolved Oxygen below 100 ppb , 1986 .

[2]  K. Schügerl,et al.  Influence of dissolved oxygen concentration on the biosynthesis of cephalosporin C. , 1992, Enzyme and microbial technology.

[3]  M E Gregory,et al.  A visual programming environment for bioprocess control. , 1994, Journal of biotechnology.

[4]  P. K. Namdev,et al.  Effect of oxygen fluctuations on recombinant Escherichia coli fermentation , 1993, Biotechnology and bioengineering.

[5]  Guy A. Dumont,et al.  Adaptive predictive control of systems with time‐varying time delay , 1993 .

[6]  Seungchul Lee,et al.  Dissolved oxygen concentration regulation using auto-tuning proportional-integral-derivative controller in fermentation process , 1991 .

[7]  J. Merchuk,et al.  On the first-order approximation to the response of dissolved oxygen electrodes for dynamic KLa estimation. , 1990, Biotechnology and bioengineering.

[8]  T. Clark,et al.  Automatic control of dissolved oxygen tension via fermenter agitation speed. , 1985, Biotechnology and bioengineering.

[9]  M. Thoma,et al.  Constant dissolved oxygen concentrations in cephalosporin C fermentation: Applicability of different controllers and effect on fermentation parameters , 1987, Applied Microbiology and Biotechnology.

[10]  J. D. Preez,et al.  AN ELECTRONIC CONTROLLER FOR MAINTAINING LOW DISSOLVED OXYGEN LEVELS IN A BENCH-TOP FERMENTOR , 1989 .

[11]  Karl O. Jones,et al.  ON-LINE AUTOMATIC TUNING PID CONTROL OF DISSOLVED OXYGEN , 1992 .

[12]  H. Chang,et al.  Adaptive control of dissolved oxygen concentration in a bioreactor , 1991, Biotechnology and bioengineering.

[13]  D. Oh,et al.  Control of dissolved oxygen concentration in mammalian cell culture using a computer-coupled mass flow controller , 1992 .

[14]  Graham C. Goodwin,et al.  Adaptive filtering prediction and control , 1984 .

[15]  J. Shiloach,et al.  Adaptive Control Strategy for Maintaining Dissolved Oxygen Concentration in High Density Growth of Recombinant E. coli , 1992, Annals of the New York Academy of Sciences.

[16]  M. M'Saad,et al.  ADAPTIVE CONTROL: AN OVERVIEW , 1992 .

[17]  David W. Clarke,et al.  Generalized predictive control - Part I. The basic algorithm , 1987, Autom..

[18]  B G Thompson,et al.  Effect of Dissolved Oxygen Control on Growth and Antibiotic Production in Streptomyces clavuligerus Fermentations , 1991, Biotechnology progress.