A new paradigm for the closed-loop intraoperative administration of analgesics in humans

We present a new paradigm for the closed-loop administration of analgesics during general anesthesia. The manipulated variable in the control system is the infusion rate of the opiate alfentanil, administered intravenously through a computer-controlled infusion pump (CCIP). The outputs to be controlled are the patient's mean arterial pressure (MAP) and the drug concentration in the plasma. Maintaining MAP within appropriate ranges provides optimal treatment of the patient's reactions to surgical stimuli. Maintaining plasma drug concentrations close to a reference value specified by the anesthesiologist allows to titrate analgesic administration to qualitative clinical end-points of insufficient analgesia. MAP is acquired invasively through a catheter cannula. Since plasma drug concentrations cannot be measured on-line, they are estimated via a pharmacokinetic model. We describe an explicit model-predictive controller which achieves the above-mentioned objectives. An upper constraint on drug concentrations is maintained to avoid overdosing. Constraints on the MAP are introduced to trigger a prompt controller reaction during hypertensive and hypotensive periods. Measurement artifacts in the MAP signal are rejected to prevent harmful misbehavior of the controller. We discuss the results of the clinical validation of the controller on humans.

[1]  Ph. Scherpereel,et al.  Analgésie contrôlée par le patient (ACP) , 1991 .

[2]  I J Rampil,et al.  No correlation between quantitative electroencephalographic measurements and movement response to noxious stimuli during isoflurane anesthesia in rats. , 1992, Anesthesiology.

[3]  A Carregal,et al.  [Intraoperative control of mean arterial pressure and heart rate with alfentanyl with fuzzy logic]. , 2000, Revista espanola de anestesiologia y reanimacion.

[4]  Andrea Luca Gentilini Feedback control of hypnosis and analgesia in humans , 2001 .

[5]  D. Coursin,et al.  Assessment of sedation, analgesia, and neuromuscular blockade in the perioperative period. , 1996, International anesthesiology clinics.

[6]  A Gentilini,et al.  Artifact-tolerant controllers for automatic drug delivery in anesthesia. , 2000, Critical reviews in biomedical engineering.

[7]  Manfred Morari,et al.  Modeling and closed-loop control of hypnosis by means of bispectral index (BIS) with isoflurane , 2001, IEEE Transactions on Biomedical Engineering.

[8]  Eberhard Kochs,et al.  Surgical Stimulation Induces Changes in Brain Electrical Activity during Isoflurane/Nitrous Oxide Anesthesia: A Topographic Electroencephalographic Analysis , 1994, Anesthesiology.

[9]  J.M. Bailey,et al.  A simple analytical solution to the three-compartment pharmacokinetic model suitable for computer-controlled infusion pumps , 1991, IEEE Transactions on Biomedical Engineering.

[10]  Christian W. Frei,et al.  Recoverability viewed as a system property , 1999, 1999 European Control Conference (ECC).

[11]  D R Stanski,et al.  Population pharmacokinetics of alfentanil: the average dose-plasma concentration relationship and interindividual variability in patients. , 1987, Anesthesiology.

[12]  I. R. Thomson,et al.  Alfentanil pharmacokinetics in patients undergoing abdominal aortic surgery , 1991, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[13]  A González,et al.  A new sodium-nitroprusside-infusion controller for the regulation of arterial blood pressure. , 1993, Biomedical instrumentation & technology.

[14]  H Schwilden,et al.  Closed-loop feedback controlled administration of alfentanil during alfentanil-nitrous oxide anaesthesia. , 1993, British journal of anaesthesia.

[15]  M. Hynynen,et al.  Continuous infusion of fentanyl or alfentanil for coronary artery surgery. Plasma opiate concentrations, haemodynamics and postoperative course. , 1986, British journal of anaesthesia.

[16]  S L Shafer,et al.  Pharmacokinetics, pharmacodynamics, and rational opioid selection. , 1991, Anesthesiology.

[17]  D. Goodman,et al.  ACCURACY OF PHARMACOKINETIC MODEL-DRIVEN INFUSION OF PROPOFOL , 1989 .

[18]  C Prys-Roberts,et al.  Anaesthesia: a practical or impractical construct? , 1987, British Journal of Anaesthesia.

[19]  D. Whalley,et al.  Narcotic Requirements for Intravenous Anesthesia , 1984, Anesthesia and analgesia.

[20]  P Scherpereel [Patient-controlled analgesia]. , 1991, Annales francaises d'anesthesie et de reanimation.

[21]  D R Stanski,et al.  Decreased fentanyl and alfentanil dose requirements with age. A simultaneous pharmacokinetic and pharmacodynamic evaluation. , 1987, The Journal of pharmacology and experimental therapeutics.

[22]  I. Rampil A Primer for EEG Signal Processing in Anesthesia , 1998, Anesthesiology.

[23]  J. Sear,et al.  Open-Loop Control Systems and Their Performance for Intravenous Anaesthetics , 1995 .

[24]  G N Kenny,et al.  Evaluation of closed-loop control of arterial pressure after cardiopulmonary bypass. , 1987, British journal of anaesthesia.

[25]  Manfred Morari,et al.  Model predictive control: Theory and practice - A survey , 1989, Autom..

[26]  Christian Walter Frei,et al.  Fault tolerant control concepts applied to anesthesia , 2000 .

[27]  Alberto Bemporad,et al.  The explicit solution of model predictive control via multiparametric quadratic programming , 2000, Proceedings of the 2000 American Control Conference. ACC (IEEE Cat. No.00CH36334).

[28]  A Gentilini,et al.  Identification and targeting policies for computer-controlled infusion pumps. , 2000, Critical reviews in biomedical engineering.

[29]  Manfred Morari,et al.  State-space interpretation of model predictive control , 1994, Autom..

[30]  荒井保明 Pharmacokinetics , 1993 .

[31]  T. Johnson,et al.  Patient controlled analgesia—assessment of machine feedback to patients , 1992, Anaesthesia.

[32]  J. van Egmond,et al.  Invasive v. non-invasive measurement of arterial pressure. Comparison of two automatic methods and simultaneously measured direct intra-arterial pressure. , 1985, British journal of anaesthesia.

[33]  J. Jacquez Compartmental analysis in biology and medicine , 1985 .

[34]  D R Stanski,et al.  Plasma Concentrations of Alfentanil Required to Supplement Nitrous Oxide Anesthesia for General Surgery , 1986, Anesthesiology.

[35]  Donald R. Stanski,et al.  Comparison of a Computer‐assisted Infusion Versus Intermittent Bolus Administration of Alfentanil as a Supplement to Nitrous Oxide for Lower Abdominal Surgery , 1988, Anesthesiology.

[36]  Steven L. Shafer,et al.  Measuring the predictive performance of computer-controlled infusion pumps , 1992, Journal of Pharmacokinetics and Biopharmaceutics.

[37]  R. Northrop,et al.  A new approach to the modeling and control of postoperative pain , 1990, IEEE Transactions on Biomedical Engineering.

[38]  G. Koski,et al.  Fentanyl and sufentanil anesthesia revisited: how much is enough? , 1990, Anesthesiology.

[39]  Lars Arendt-Nielsen,et al.  Do Results From Experimental Nociceptive Models Reflect Pain Perception During General Anesthesia , 1998 .

[40]  Toru Masuzawa,et al.  Knowledge-based approach to intelligent alarms , 1989, Journal of Clinical Monitoring.

[41]  Graham C. Goodwin,et al.  Adaptive filtering prediction and control , 1984 .