DLR MiroSurge: a versatile system for research in endoscopic telesurgery

PurposeResearch on surgical robotics demands systems for evaluating scientific approaches. Such systems can be divided into dedicated and versatile systems. Dedicated systems are designed for a single surgical task or technique, whereas versatile systems are designed to be expandable and useful in multiple surgical applications. Versatile systems are often based on industrial robots, though, and because of this, are hardly suitable for close contact with humans.MethodTo achieve a high degree of versatility the Miro robotic surgery platform (MRSP) consists of versatile components, dedicated front–ends towards surgery and configurable interfaces for the surgeon.ResultsThis paper presents MiroSurge, a configuration of the MRSP that allows for bimanual endoscopic telesurgery with force feedback.ConclusionsWhile the components of the MiroSurge system are shown to fulfil the rigid design requirements for robotic telesurgery with force feedback, the system remains versatile, which is supposed to be a key issue for the further development and optimisation.

[1]  Micha Sharir,et al.  Partial surface and volume matching in three dimensions , 1994, Proceedings of the 12th IAPR International Conference on Pattern Recognition, Vol. 3 - Conference C: Signal Processing (Cat. No.94CH3440-5).

[2]  Gerd Hirzinger,et al.  Image stabilisation of the beating heart by local linear interpolation , 2006, SPIE Medical Imaging.

[3]  Stefan Döbele Die transpedikuläre Bohrung: eine biomechanische und theoretische Analyse der transpedikulären Bohrung zur Auslegung eines navigationsgestützten, semi-aktiven Roboters , 2008 .

[4]  Bernhard Kübler,et al.  Development of actuated and sensor integrated forceps for minimally invasive robotic surgery , 2006 .

[5]  Luc Soler,et al.  IN VIVO STUDY OF FORCES DURING NEEDLE INSERTIONS , 2004 .

[6]  Tobias Ortmaier,et al.  Motion estimation in beating heart surgery , 2005, IEEE Transactions on Biomedical Engineering.

[7]  G Hirzinger,et al.  Development of actuated and sensor integrated forceps for minimally invasive robotic surger , 2005, The international journal of medical robotics + computer assisted surgery : MRCAS.

[8]  Christopher R. Wagner,et al.  The role of force feedback in surgery: analysis of blunt dissection , 2002, Proceedings 10th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. HAPTICS 2002.

[9]  Di Xiao,et al.  Ultrasound Guided Robotic System for Transperineal Biopsy of the Prostate , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[10]  Gerd Hirzinger,et al.  Structure driven substitution of specular reflections for realtime heart surface tracking , 2005, IEEE International Conference on Image Processing 2005.

[11]  Christian Ott,et al.  Concepts of Human-Robot Cooperation for a new Medical Robot , 2006 .

[12]  Tobias Ortmaier,et al.  A hands-on-robot for accurate placement of pedicle screws , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[13]  Yongde Zhang,et al.  Evaluation of robotic needle insertion in conjunction with in vivo manual insertion in the operating room , 2005, ROMAN 2005. IEEE International Workshop on Robot and Human Interactive Communication, 2005..

[14]  Tobias Ortmaier,et al.  A Co-Robotic Positioning Device for Carrying Surgical End-Effectors , 2006 .

[15]  Allison M Okamura,et al.  Effect of sensory substitution on suture manipulation forces for surgical teleoperation. , 2004, Studies in health technology and informatics.

[16]  W R Walsh,et al.  Resistance forces acting on suture needles. , 2001, Journal of biomechanics.

[17]  J. Bowersox,et al.  Telepresence surgery , 1996, The British journal of surgery.

[18]  Allison M. Okamura,et al.  Force modeling for needle insertion into soft tissue , 2004, IEEE Transactions on Biomedical Engineering.

[19]  Alin Albu-Schäffer,et al.  Safety Evaluation of Physical Human-Robot Interaction via Crash-Testing , 2007, Robotics: Science and Systems.

[20]  Jadran Lenarčič,et al.  Advances in Robot Kinematics , 2000 .

[21]  Natalie Smith-Guerin,et al.  A medical robot kinematics design approach based on knowledge management , 2008, Ind. Robot.

[22]  Alin Albu-Schäffer,et al.  A passivity based Cartesian impedance controller for flexible joint robots - part I: torque feedback and gravity compensation , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[23]  S. Hassfeld,et al.  Sternotomie und Kraniotomie mithilfe autonomer Roboter , 2007, Zeitschrift für Herz-,Thorax- und Gefäßchirurgie.

[24]  Min-Seok Kim,et al.  복강경 수술용 도구의 실시간 영상 추적 및 복강경 조종기의 지능형 제어 방법 = Real-time visual servoing for laparoscopic surgery , 2003 .

[25]  Rajni V. Patel,et al.  Needle insertion into soft tissue: a survey. , 2007, Medical engineering & physics.

[26]  Alin Albu-Schäffer,et al.  The DLR MIRO: a versatile lightweight robot for surgical applications , 2008, Ind. Robot.

[27]  Tobias Ortmaier,et al.  Tracking local motion on the beating heart , 2002, SPIE Medical Imaging.

[28]  Berthold Bäuml,et al.  Agile Robot Development (aRD): A Pragmatic Approach to Robotic Software , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[29]  Gerd Hirzinger,et al.  DLR MiroSurge -- towards versatility in surgical robotics , 2008 .

[30]  Rainer Christian Konietschke,et al.  Planning of Workplaces with Multiple Kinematically Redundant Robots , 2007 .

[31]  Gerd Hirzinger,et al.  The 3D-Modeller: A Multi-Purpose Vision Platform , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[32]  P. Green,et al.  Telepresence surgery , 1995 .

[33]  Gerd Hirzinger,et al.  Prototypic Force Feedback Instrument for Minimally Invasive Robotic Surgery , 2008 .

[34]  Alin Albu-Schäffer,et al.  MIMO State Feedback Controller for a Flexible Joint Robot with Strong Joint Coupling , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[35]  Tobias Ortmaier,et al.  Manipulability and Accuracy Measures for a Medical Robot in Minimally Invasive Surgery , 2004 .

[36]  G. Hirzinger,et al.  Real-time visual servoing for laparoscopic surgery. Controlling robot motion with color image segmentation , 1997, IEEE Engineering in Medicine and Biology Magazine.