Challenges in using compliant ligaments for position estimation within robotic joints

The mechanical advantages of bio-inspired condylar robotic knee joints for use in prosthetics or rehabilitation has been argued extensively in literature. A common limitation of these designs is the difficulty of estimating joint angle and therefore accurately controlling the joint. Furthermore, the potential role of ligament-like structures in robotic knees is not very well established. In this work, we investigate the role of compliant stretch sensing ligaments and their integration into a condylar robotic knee. Simulations and experiments are executed out in order to establish whether measurement of stretch in these structures can be used to produce a new feedback controller for joint position. We report results from a computer model, as well as the design and construction of a robotic knee that show, for a chosen condyle shape, ligament stretch is a function of muscle force and joint velocity as well as joint angle. We have developed a genetic algorithm optimised controller incorporating ligament feedback that demonstrates improved performance for a desired joint angle in response to step inputs. The controller showed marginal improvement in response to a cyclic command signal and further investigation is required in order to use these measurements in robust control, nevertheless we believe these results demonstrate the that ligament-like structures have the potential to improve the performance of robotic knees for prosthetics and rehabilitation devices.

[1]  J P Corrigan,et al.  Proprioception in the cruciate deficient knee. , 1992, The Journal of bone and joint surgery. British volume.

[2]  Annegret Mündermann,et al.  In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement , 2008, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  F. Girgis,et al.  The cruciate ligaments of the knee joint. Anatomical, functional and experimental analysis. , 1975, Clinical orthopaedics and related research.

[4]  K Yamakoshi,et al.  Simultaneous measurement of changes in length of the cruciate ligaments during knee motion. , 1991, Clinical orthopaedics and related research.

[5]  R A Brand,et al.  Mechanoreceptors in joint function. , 1998, The Journal of bone and joint surgery. American volume.

[6]  Umberto Scarfogliero,et al.  A Biologically Founded Design and Control of a Humanoid Biped , 2009 .

[7]  Freddie H Fu,et al.  MRI measurement of the 2 bundles of the normal anterior cruciate ligament. , 2009, Orthopedics.

[8]  W. Marsden I and J , 2012 .

[9]  Martijn Wisse,et al.  A Three-Dimensional Passive-Dynamic Walking Robot with Two Legs and Knees , 2001, Int. J. Robotics Res..

[10]  F. Awiszus,et al.  Detailed analysis of proprioception in normal and ACL-deficient knees. , 1999, The Journal of bone and joint surgery. British volume.

[11]  Scott M Lephart,et al.  The sensorimotor system, part I: the physiologic basis of functional joint stability. , 2002, Journal of athletic training.

[12]  R. Baxendale,et al.  The influence of joint afferent discharge on locomotion, proprioception and activity in conscious cats , 1985, Brain Research.

[13]  Darwin G. Caldwell,et al.  Bio-inspired knee joint mechanism for a hydraulic quadruped robot , 2015, 2015 6th International Conference on Automation, Robotics and Applications (ICARA).

[14]  Clare Frank The Sensorimotor System , 2015 .

[15]  A B Zavatsky,et al.  A kinematic-freedom analysis of a flexed-knee-stance testing rig. , 1997, Journal of biomechanics.

[16]  James A. Ashton-Miller,et al.  The Relationship between Quadriceps Muscle Force, Knee Flexion, and Anterior Cruciate Ligament Strain in an in Vitro Simulated Jump Landing , 2006, The American journal of sports medicine.

[17]  T S Buchanan,et al.  Selective muscle activation following electrical stimulation of the collateral ligaments of the human knee joint. , 1995, Archives of physical medicine and rehabilitation.

[18]  S. Woo,et al.  The importance of quadriceps and hamstring muscle loading on knee kinematics and in-situ forces in the ACL. , 1999, Journal of biomechanics.

[19]  Zwe-Lee Gaing A particle swarm optimization approach for optimum design of PID controller in AVR system , 2004, IEEE Transactions on Energy Conversion.

[20]  S Arai,et al.  The use of robotics technology to study human joint kinematics: a new methodology. , 1993, Journal of biomechanical engineering.

[21]  Friedemann Awiszus,et al.  Detailed analysis of proprioception in normal and ACL-deficient knees , 1999 .

[22]  Ravi Vaidyanathan,et al.  A Bio-Inspired Condylar Hinge for Robotic Limbs , 2013 .

[23]  Chandana Paul,et al.  Low-bandwidth reflex-based control for lower power walking: 65 km on a single battery charge , 2014, Int. J. Robotics Res..

[24]  Clément Gosselin,et al.  A Compliant Rolling Contact Joint and Its Application in a 3-DOF Planar Parallel Mechanism With Kinematic Analysis , 2004 .

[25]  M J Pearcy,et al.  Mechanical properties of the human anterior cruciate ligament. , 1995, Clinical biomechanics.

[26]  H. Johansson,et al.  A sensory role for the cruciate ligaments. , 1991, Clinical orthopaedics and related research.

[27]  H.W.J. Huiskes,et al.  Basic orthopaedic biomechanics and mechano-biology , 2005 .

[28]  W. Ferrell The adequacy of stretch receptors in the cat knee joint for signalling joint angle throughout a full range of movement. , 1980, The Journal of physiology.

[29]  Louis F. Draganich,et al.  An in-vitro study of anterior cruciate ligament strain induced by quadriceps and hamstrings forces , 1990 .

[30]  R. D'ambrosia,et al.  Muscular coactivation , 1988, The American journal of sports medicine.

[31]  S. Gard,et al.  The Influence of Four‐Bar Linkage Knees on Prosthetic Swing‐Phase Floor Clearance , 1996 .