Nanotechnology: a systems and control approach

Recent years have seen significant advances in the fields of nanosciences and nanotechnology. A significant part of the research in nanotechnology deals with developing tools and devices to probe and manipulate matter at the atomic, molecular and macro-molecular levels. Surprisingly in spite of the potential for engineers to contribute substantially to this area, most of the contributions till date have come from physicists and biologists. Engineering ideas primarily from systems theory and control significantly complement the physical studies performed in this area of research. This thesis demonstrates this by the application of systems ideas and tools to address two of the most important goals of nanotechnology, interrogation and positioning of materials at the nanoscale. The atomic force microscope (AFM), a micro-cantilever based device is one of the foremost tools in the interrogation and manipulation of matter at the atomic scale. The AFM operating in the most common tapping-mode has a highly complex dynamics due to the nonlinear tip-sample interaction forces. A systems approach is proposed to analyze the tapping-mode dynamics. The systems perspective is further exploited to develop analytical tools for modeling and identifying tip sample interactions. Some of the distinctly nonlinear features of tapping-mode operation are explained using the asymptotic theory of weakly nonlinear oscillators developed by Bogoliubov and Mitropolski. In the nanopositioning front, through the design and implementation of nanopositioning devices, a new paradigm for the systematic design of nanopositioners with specific bandwidth, resolution and robustness requirements is presented. Many tools from modern robust control like nominal and robust Hoo designs and Glover McFarlane designs are exploited for this. The experimental results demonstrate the efficacy of these design schemes.

[1]  D. Croft,et al.  Creep, Hysteresis, and Vibration Compensation for Piezoactuators: Atomic Force Microscopy Application , 2001 .

[2]  Sanjit K. Mitra,et al.  Digital Signal Processing: A Computer-Based Approach , 1997 .

[3]  I. Mezić,et al.  On the Dynamics of a Harmonic Oscillator Undergoing Impacts with a Vibrating Platform , 2001 .

[4]  H. Rothuizen,et al.  "Millipede": a MEMS-based scanning-probe data-storage system , 2002, Digest of the Asia-Pacific Magnetic Recording Conference.

[5]  Ricardo Garcia,et al.  Tip-surface forces, amplitude, and energy dissipation in amplitude-modulation (tapping mode) force microscopy , 2001 .

[6]  K. Glover,et al.  Robust stabilization of normalized coprime factor plant descriptions with H/sub infinity /-bounded uncertainty , 1989 .

[7]  Ian Postlethwaite,et al.  Multivariable Feedback Control: Analysis and Design , 1996 .

[8]  B G De Grooth,et al.  Biomolecular interactions measured by atomic force microscopy. , 2000, Biophysical journal.

[9]  Murti V. Salapaka,et al.  Robust control approach to atomic force microscopy , 2003, 42nd IEEE International Conference on Decision and Control (IEEE Cat. No.03CH37475).

[10]  Harald Fuchs,et al.  Basic properties of dynamic force spectroscopy with the scanning force microscope in experiment and simulation , 1996 .

[11]  M. Marth,et al.  A unifying view on some experimental effects in tapping-mode atomic force microscopy , 1999 .

[12]  E. McFarland,et al.  Multi-mode noise analysis of cantilevers for scanning probe microscopy , 1997 .

[13]  Nguyen Van Dao,et al.  Applied asymptotic methods in nonlinear oscillations , 1997 .

[14]  Srinivasa M. Salapaka,et al.  H/sub /spl infin// loop shaping design for nano-positioning , 2003, Proceedings of the 2003 American Control Conference, 2003..

[15]  Dynamics of the cantilever in noncontact dynamic force microscopy: The steady-state approximation and beyond , 2001 .

[16]  R. Barrett,et al.  Optical scan‐correction system applied to atomic force microscopy , 1991 .

[17]  Keith Glover,et al.  A loop-shaping design procedure using H/sub infinity / synthesis , 1992 .

[18]  Hermann E. Gaub,et al.  Discrete interactions in cell adhesion measured by single-molecule force spectroscopy , 2000, Nature Cell Biology.

[19]  Gerber,et al.  Atomic Force Microscope , 2020, Definitions.

[20]  Ian Postlethwaite,et al.  Pole-zero cancellations and closed-loop properties of an H∞ mixed sensitivity design problem , 1992, Autom..

[22]  F. Allgöwer,et al.  High performance feedback for fast scanning atomic force microscopes , 2001 .

[23]  A. Sebastian,et al.  Analysis of periodic solutions in tapping-mode AFM : An IQC approach , 2002 .

[24]  Burnham,et al.  Nanosubharmonics: The dynamics of small nonlinear contacts. , 1995, Physical review letters.

[25]  Ricardo Garcia,et al.  Tip motion in amplitude modulation (tapping-mode) atomic-force microscopy: Comparison between continuous and point-mass models , 2002 .

[26]  Murti V. Salapaka,et al.  Dynamical analysis and control of microcantilevers , 1999, Autom..

[27]  L. Wang,et al.  Analytical descriptions of the tapping-mode atomic force microscopy response , 1998 .

[28]  Keith Glover,et al.  Pole/zero concellations in general H(infinity) problem with reference to a two block design , 1990 .

[29]  Murti V. Salapaka,et al.  An observer based sample detection scheme for atomic force microscopy , 2003, 42nd IEEE International Conference on Decision and Control (IEEE Cat. No.03CH37475).

[30]  Evanghelos Zafiriou,et al.  Robust process control , 1987 .

[31]  Gene F. Franklin,et al.  Feedback Control of Dynamic Systems , 1986 .

[32]  A. Sebastian,et al.  Thermal noise response based control of tip-sample separation in AFM , 2004, Proceedings of the 2004 American Control Conference.

[33]  D. Rugar,et al.  Mechanical detection of magnetic resonance , 1992, Nature.

[34]  Murti V. Salapaka,et al.  Harmonic analysis based modeling of tapping-mode AFM , 1999, Proceedings of the 1999 American Control Conference (Cat. No. 99CH36251).

[35]  Sidles Ja,et al.  Folded Stern-Gerlach experiment as a means for detecting nuclear magnetic resonance in individual nuclei. , 1992 .

[36]  A. Sebastian,et al.  The amplitude phase dynamics and fixed points in tapping-mode atomic force microscopy , 2004, Proceedings of the 2004 American Control Conference.

[37]  D. Luenberger Optimization by Vector Space Methods , 1968 .

[38]  Murti V. Salapaka,et al.  Transient-signal-based sample-detection in atomic force microscopy , 2003 .

[39]  R. Koops,et al.  NEW SCANNING DEVICE FOR SCANNING TUNNELING MICROSCOPE APPLICATIONS , 1992 .

[40]  Jason Cleveland,et al.  Energy dissipation in tapping-mode atomic force microscopy , 1998 .

[41]  Murti V. Salapaka,et al.  High bandwidth nano-positioner: A robust control approach , 2002 .

[42]  Murti V. Salapaka,et al.  System tools applied to micro-cantilever based devices , 2003 .

[43]  U. Dürig,et al.  Extracting interaction forces and complementary observables in dynamic probe microscopy , 2000 .

[44]  Hiroshi Kaizuka Application of capacitor insertion method to scanning tunneling microscopes , 1989 .

[45]  Murti V. Salapaka,et al.  Harmonic and power balance tools for tapping-mode atomic force microscope , 2001 .

[46]  A. Rantzer,et al.  System analysis via integral quadratic constraints , 1997, IEEE Trans. Autom. Control..

[47]  Murti V. Salapaka,et al.  Piezoelectric scanners for atomic force microscopes: design of lateral sensors, identification and control , 1999, Proceedings of the 1999 American Control Conference (Cat. No. 99CH36251).

[48]  H. Rothuizen,et al.  Translating biomolecular recognition into nanomechanics. , 2000, Science.

[49]  A. Rantzer,et al.  Harmonic analysis of nonlinear and uncertain systems , 1998, Proceedings of the 1998 American Control Conference. ACC (IEEE Cat. No.98CH36207).

[50]  Sidles Folded Stern-Gerlach experiment as a means for detecting nuclear magnetic resonance in individual nuclei. , 1992, Physical review letters.

[51]  Joseph L. Garbini,et al.  The theory of oscillator-coupled magnetic resonance with potential applications to molecular imaging , 1992 .

[52]  Stephen W. Howell,et al.  Nonlinear dynamics of microcantilevers in tapping mode atomic force microscopy: A comparison between theory and experiment , 2002 .